Literature DB >> 21940572

Predictors of image quality in high-pitch coronary CT angiography.

Paul Stolzmann1, Robert P Goetti, Pal Maurovich-Horvat, Udo Hoffmann, Thomas G Flohr, Sebastian Leschka, Hatem Alkadhi.   

Abstract

OBJECTIVE: High-pitch coronary CT angiography (CTA) shows an alternative coronary CTA protocol to retrospectively ECG-gated imaging that is associated with a significantly lower radiation exposure. Yet, the diagnostic quality of high-pitch coronary CTA cannot be sufficiently predicted on the basis of heart rate (HR) alone. Thus, we sought to prospectively identify the predictors of diagnostic high-pitch coronary CTA. SUBJECTS AND METHODS: One hundred consecutive patients (16 women, 84 men; mean age, 67 ± 10 years) without restrictions in HR frequency or variability underwent prospectively ECG-gated high-pitch coronary artery calcification (CAC) scoring and coronary CTA using dual-source 128-MDCT. High-pitch CAC was graded on the basis of motion artifacts; high-pitch coronary CTA was graded on the basis of image quality by each of two independent and blinded readers. Predictors of coronary CTA image quality were assessed by multivariate logistic regression, including body mass index, risk of coronary artery disease, Agatston score, HR frequency and variability, and motion artifacts on CAC. If high-pitch coronary CTA was nondiagnostic, the examination was repeated using a retrospectively ECG-gated coronary CTA protocol.
RESULTS: HR frequency (66 ± 20 beats per minute [bpm]) and variability (12 ± 10 bpm) during high-pitch coronary CTA was not significantly different from that during high-pitch CAC. Interobserver agreement for image quality reading was good (k = 0.79) for CAC and excellent (k = 0.88) for coronary CTA. High-pitch CAC showed no motion artifacts in 1304 of 1396 segments (93.4%) in 78 of 100 patients. Diagnostic image quality of high-pitch coronary CTA was found in 1413 of 1457 segments (97%) in 82 of 100 patients. Multivariate logistic regression revealed HR frequency (odds ratio, 1.04; p < 0.05) and motion artifacts on preceding high-pitch CAC (odds ratio, 94.55; p < 0.001) as significant independent predictors of image quality of high-pitch coronary CTA. The mean effective radiation doses of high-pitch CAC and coronary CTA were 0.4 ± 0.1 mSv (0.3-0.5 mSv) and 1.0 ± 0.2 mSv (0.8-1.2 mSv; p < 0.001), respectively.
CONCLUSION: HR frequency and motion artifacts on preceding high-pitch CAC represent significant independent predictors of image quality in high-pitch coronary CTA.

Entities:  

Mesh:

Year:  2011        PMID: 21940572     DOI: 10.2214/AJR.10.6072

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  13 in total

1.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

Authors:  Sonja Gordic; Daniela B Husarik; Lotus Desbiolles; Sebastian Leschka; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-11       Impact factor: 2.357

2.  Image Quality of 256-Slice Computed Tomography for Coronary Angiography.

Authors:  Shu-Ping Chao; Jyh-Gang Leu; Wai-Yip Law; Chu-Jen Kuo; Kou-Gi Shyu
Journal:  Acta Cardiol Sin       Date:  2013-09       Impact factor: 2.672

3.  In vivo radiation dosimetry and image quality of turbo-flash and retrospective dual-source CT coronary angiography.

Authors:  Nicolò Schicchi; Alberto Mari; Marco Fogante; Paolo Esposto Pirani; Giacomo Agliata; Niccolò Tosi; Pierpaolo Palumbo; Ester Cannizzaro; Federico Bruno; Alessandra Splendiani; Ernesto Di Cesare; Stefania Maggi; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-11-05       Impact factor: 3.469

4.  Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease.

Authors:  Yuichiro Kanie; Shuhei Sato; Akihiro Tada; Susumu Kanazawa
Journal:  Pediatr Cardiol       Date:  2017-07-08       Impact factor: 1.655

5.  Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners.

Authors:  Liang Jin; Ji'an Zhou; Yiyi Gao; Wei Zhao; Ming Li; Zhizhong Wang
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

6.  Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

Authors:  Fabian Morsbach; Sonja Gordic; Lotus Desbiolles; Daniela Husarik; Thomas Frauenfelder; Bernhard Schmidt; Thomas Allmendinger; Simon Wildermuth; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2014-05-17       Impact factor: 5.315

7.  Non-Gated Triple Flash Coronary Computed Tomographic Angiography in Patients with Atrial Fibrillation.

Authors:  Rami M Abazid; Osama A Smettei; Akram F Eldesoky; Hanaa Al Saqqah; Habiba S Alenzi; Nora A Altorbak; Sarah S Altorbak; Mehboob Ali Dar
Journal:  Acta Cardiol Sin       Date:  2018-07       Impact factor: 2.672

8.  High-pitch computed tomography coronary angiography-a new dose-saving algorithm: estimation of radiation exposure.

Authors:  Dominik Ketelsen; Markus Buchgeister; Andreas Korn; Michael Fenchel; Bernhard Schmidt; Thomas G Flohr; Christoph Thomas; Christoph Schabel; Ilias Tsiflikas; Roland Syha; Claus D Claussen; Martin Heuschmid
Journal:  Radiol Res Pract       Date:  2012-05-31

9.  High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols.

Authors:  Long Jiang Zhang; Li Qi; Carlo N De Cecco; Chang Sheng Zhou; James V Spearman; U Joseph Schoepf; Guang Ming Lu
Journal:  Medicine (Baltimore)       Date:  2014-11       Impact factor: 1.889

Review 10.  Multimodality Imaging in Coronary Artery Disease: Focus on Computed Tomography.

Authors:  Ji Hyun Lee; Donghee Han; Ibrahim Danad; Bríain Ó Hartaigh; Fay Y Lin; James K Min
Journal:  J Cardiovasc Ultrasound       Date:  2016-03-24
View more