Literature DB >> 21926852

Noninvasive imaging after stent-assisted coiling of intracranial aneurysms: comparison of 3-T magnetic resonance imaging and 64-row multidetector computed tomography--a pilot study.

Attila Kovács1, Markus Möhlenbruch, Dariusch Reza Hadizadeh, Mirko Seifert, Susanne Greschus, Hans Clusmann, Winfried Albert Willinek, Sebastian Flacke, Horst Urbach.   

Abstract

BACKGROUND AND
PURPOSE: Follow-up imaging after stent-assisted coiling of intracranial aneurysms is limited by signal loss in the stented vessel segment using magnetic resonance imaging or by streak artifacts caused by aneurysm coils using multidetector computed tomography. In the search for a noninvasive surveillance in this condition, we propose a technique to minimize streak artifacts in multidetector computed tomography by gated data reconstruction and shifting the reconstruction window.
METHODS: The effect of the gated data acquisition in 64-row computed tomographic angiography (gCTA) on artifact reduction was evaluated in a preliminary phantom study and compared with nongated CTA, time-of-flight magnetic resonance angiography (TOF-MRA), and digital subtraction angiography (DSA). Scans were also obtained from 5 patients treated with stent-assisted coiling as part of their follow-up protocol. The length of impaired vessel segments (LIVS) in TOF-MRA and gCTA was compared and correlated with the stent's length, the number of coils, and the packing density. The assessment of treatment outcome in TOF-MRA and gCTA was compared with DSA as the standard of reference.
RESULTS: The phantom study revealed 2 aspects: first, a distinct reduction of streak artifacts caused by coils using gated data acquisition; and second, because artifact orientation could be rotated systematically by shifting the reconstruction window, visualization of treated vessel segments was significantly superior in gCTA. In magnetic resonance imaging, all stented vessel segments were characterized by signal loss in both phantom and patients. The LIVS was 78% shorter in gCTA (4.86 ± 6.93 mm) compared with that in TOF-MRA (21.82 ± 7.47 mm, P < 0.01). In TOF-MRA, the LIVS correlated with the stent's length, in gCTA with the number of coils. With regard to assessment of treatment outcome, gCTA and TOF-MRA correlated with DSA in 3 and in none of 5 patients, respectively.
CONCLUSIONS: Gated CTA is a promising technique to reduce the amount of artifacts induced by stent-assisted intracranial coils. Image quality and assessment of treatment outcome in patients with stent-assisted coiling is superior compared with TOF-MRA.

Entities:  

Mesh:

Year:  2011        PMID: 21926852     DOI: 10.1097/RCT.0b013e318224e528

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  8 in total

1.  The pCONus Device in Treatment of Wide-necked Aneurysms : Technical and Midterm Clinical and Angiographic Results.

Authors:  C Ulfert; J Pfaff; S Schönenberger; J Bösel; C Herweh; M Pham; M Bendszus; M Möhlenbruch
Journal:  Clin Neuroradiol       Date:  2016-09-16       Impact factor: 3.649

Review 2.  Acute rerupture after coil embolization of ruptured intracranial saccular aneurysms: A literature review.

Authors:  Kailing Li; Yunbao Guo; Ying Zhao; Baofeng Xu; Kan Xu; Jinlu Yu
Journal:  Interv Neuroradiol       Date:  2017-12-12       Impact factor: 1.610

3.  Usefulness of contrast-enhanced and TOF MR angiography for follow-up after low-profile stent-assisted coil embolization of intracranial aneurysms.

Authors:  Selcuk Akkaya; Onur Akca; Anıl Arat; Ahmet Peker; Sinan Balci
Journal:  Interv Neuroradiol       Date:  2018-07-05       Impact factor: 1.610

4.  Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight MR angiography at 3T and 1.5T in a large prospective series.

Authors:  L Pierot; C Portefaix; J-Y Gauvrit; A Boulin
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-07       Impact factor: 3.825

5.  The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy.

Authors:  M Möhlenbruch; C Herweh; L Behrens; L Jestaedt; H Amiri; P A Ringleb; M Bendszus; M Pham
Journal:  Neuroradiology       Date:  2014-03-06       Impact factor: 2.804

6.  Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series.

Authors:  Laurent Pierot; Christophe Portefaix; Anne Boulin; Jean-Yves Gauvrit
Journal:  Eur Radiol       Date:  2012-05-09       Impact factor: 5.315

7.  Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images.

Authors:  Young Dae Cho; Kang Min Kim; Woong Jae Lee; Chul-Ho Sohn; Hyun-Seung Kang; Jeong Eun Kim; Moon Hee Han
Journal:  Korean J Radiol       Date:  2014-01-08       Impact factor: 3.500

8.  A three-dimensional digital visualization model of cervical nerves in a healthy person.

Authors:  Jiaming Cao; Dong Fu; Sen Li
Journal:  Neural Regen Res       Date:  2013-07-15       Impact factor: 5.135