Literature DB >> 24599219

The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy.

M Möhlenbruch1, C Herweh, L Behrens, L Jestaedt, H Amiri, P A Ringleb, M Bendszus, M Pham.   

Abstract

INTRODUCTION: This study was aimed to assess clinical safety and efficacy of the LVIS Jr. microstent in stent-assisted coil embolization of wide-neck intracranial aneurysms.
METHODS: IRB approved single-center interventional clinical study in 22 patients (10 females, 12 males, mean age 55, age range 33-74 years) for the endovascular treatment of wide-neck aneurysms. After obtaining informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio < 2 or neck diameter > 4 mm, and a parent vessel diameter of ≤3.5 mm. Primary end point for clinical safety was absence of death, absence of major or minor stroke, and absence of transient ischemic attack. Primary end point for treatment efficacy was complete angiographic occlusion according to the Raymond-Roy Occlusion Classification (RROC) immediately after the procedure and at follow-up after 3 and 6 months on magnetic resonance imaging (MRI).
RESULTS: In 20/22 (91 %) of patients, the primary end point of safety was reached; in the two remaining patients, transient ischemic attack, but no permanent deficit was observed; in 16/22 (73 %), efficient occlusion (RROC1) was reached, and in 6/22 (27 %), a residual neck remained (RROC2). Single [seven with antegrade, two in crossover configuration, and four with "first-balloon-then-stent" (FBTS) technique] or double-stent (eight patients with Y configuration and one patient with X configuration) deployment was technically successful in all cases.
CONCLUSION: Deployment of the LVIS Jr. microstent in various single- or double-stent configurations is safe and effective to assist the treatment of intracranial wide-neck aneurysms.

Entities:  

Mesh:

Year:  2014        PMID: 24599219     DOI: 10.1007/s00234-014-1345-z

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  18 in total

1.  Possible mechanisms for delayed migration of the closed cell--designed enterprise stent when used in the adjunctive treatment of a basilar artery aneurysm.

Authors:  B Gao; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2010-09-30       Impact factor: 3.825

2.  Preliminary experience with the enterprise stent for endovascular treatment of complex intracranial aneurysms: potential advantages and limiting characteristics.

Authors:  Boris Lubicz; Olivier François; Marc Levivier; Jacques Brotchi; Danielle Balériaux
Journal:  Neurosurgery       Date:  2008-05       Impact factor: 4.654

3.  The "Remodelling Technique" in the Treatment of Wide Neck Intracranial Aneurysms. Angiographic Results and Clinical Follow-up in 56 Cases.

Authors:  J Moret; C Cognard; A Weill; L Castaings; A Rey
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

4.  Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study.

Authors:  Benjamin Gory; Joachim Klisch; Alain Bonafé; Charbel Mounayer; Remy Beaujeux; Jacques Moret; Boris Lubicz; Roberto Riva; Francis Turjman
Journal:  Neuroradiology       Date:  2013-09-22       Impact factor: 2.804

5.  MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils.

Authors:  Charles B L M Majoie; Marieke E Sprengers; Willem Jan J van Rooij; Cristina Lavini; Menno Sluzewski; Jeroen C van Rijn; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

6.  A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms.

Authors:  Werner Weber; Martin Bendszus; Bernhard Kis; Thierry Boulanger; László Solymosi; Dietmar Kühne
Journal:  Neuroradiology       Date:  2007-05-03       Impact factor: 2.804

7.  Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up.

Authors:  Alessandra Biondi; Vallabh Janardhan; Jeffrey M Katz; Kimberly Salvaggio; Howard A Riina; Y Pierre Gobin
Journal:  Neurosurgery       Date:  2007-09       Impact factor: 4.654

8.  Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience.

Authors:  Boris Lubicz; Xavier Leclerc; Marc Levivier; Jacques Brotchi; Jean-Pierre Pruvo; Jean-Paul Lejeune; Danielle Balériaux
Journal:  Neurosurgery       Date:  2006-03       Impact factor: 4.654

9.  Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms.

Authors:  Alejandro M Spiotta; Amrendra Miranpuri; M Imran Chaudry; Raymond D Turner; Aquilla S Turk
Journal:  J Neurointerv Surg       Date:  2012-11-20       Impact factor: 5.836

10.  Comparison of devices used for stent-assisted coiling of intracranial aneurysms.

Authors:  Benjamin Izar; Ansaar Rai; Karthikram Raghuram; Jill Rotruck; Jeffrey Carpenter
Journal:  PLoS One       Date:  2011-09-22       Impact factor: 3.240

View more
  25 in total

1.  LEO Baby Stent Use following Balloon-Assisted Coiling: Single- and Dual-Stent Technique--Immediate and Midterm Results of 29 Consecutive Patients.

Authors:  P Machi; V Costalat; K Lobotesis; C Ruiz; Y B Cheikh; O Eker; G Gascou; F Danière; C Riquelme; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

2.  Cerebral aneurysms treated with low-profile visualized intraluminal support device (LVIS Jr) Y-stent constructs: Technical experience with a single microcatheter technique.

Authors:  Colin Son; Paul Page; David Niemann
Journal:  Interv Neuroradiol       Date:  2019-12-18       Impact factor: 1.610

3.  One-pass endovascular treatment of intracranial atherosclerotic stenosis with a novel PTA balloon and self-expanding microstent.

Authors:  Markus A Möhlenbruch; Johannes Pfaff; Christian Herweh; Julian Bösel; Timolaos Rizos; Simon Nagel; Peter A Ringleb; Martin Bendszus; Mirko Pham
Journal:  Neuroradiology       Date:  2016-06-16       Impact factor: 2.804

Review 4.  Utility of bulging technique for endovascular treatment of small and wide-necked aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr.) device: A case report and review of the literature.

Authors:  Akihiro Inoue; Masahiko Tagawa; Shirabe Matsumoto; Masahiro Nishikawa; Kosuke Kusakabe; Hideaki Watanabe; Takeharu Kunieda
Journal:  Interv Neuroradiol       Date:  2017-11-21       Impact factor: 1.610

5.  LVIS Jr. stent for treatment of intracranial aneurysms with parent vessel diameter of 2.5 mm or less.

Authors:  Alejandro Santillan; Srikanth Boddu; Justin Schwarz; Ning Lin; Y Pierre Gobin; Jared Knopman; Athos Patsalides
Journal:  Interv Neuroradiol       Date:  2018-02-20       Impact factor: 1.610

6.  Dual stenting using low-profile LEO baby stents for the endovascular management of challenging intracranial aneurysms.

Authors:  I Akmangit; K Aydin; S Sencer; O M Topcuoglu; E D Topcuoglu; E Daglioglu; M Barburoglu; A Arat
Journal:  AJNR Am J Neuroradiol       Date:  2014-09-18       Impact factor: 3.825

7.  Non-Contrast-Enhanced Silent Scan MR Angiography of Intracranial Anterior Circulation Aneurysms Treated with a Low-Profile Visualized Intraluminal Support Device.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; K Teranishi; K Yatomi; N Hamasaki; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2017-05-18       Impact factor: 3.825

8.  Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?

Authors:  Jeongjun Lee; Young Dae Cho; Dong Hyun Yoo; Hyun-Seung Kang; Won-Sang Cho; Jeong Eun Kim; Jusun Moon; Moon Hee Han
Journal:  Neuroradiology       Date:  2018-04-20       Impact factor: 2.804

9.  Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.

Authors:  Su-Yeon Park; Jae-Sang Oh; Hyuk-Jin Oh; Seok-Mann Yoon; Hack-Gun Bae
Journal:  Interv Neurol       Date:  2017-04-26

10.  Endovascular treatment of patients with intracranial aneurysms: feasibility and successful employment of a new low profile visible intraluminal support (LVIS) EVO stent.

Authors:  Alexander Sirakov; Pervinder Bhogal; Markus Möhlenbruch; Stanimir Sirakov
Journal:  Neuroradiol J       Date:  2020-07-21
View more