Literature DB >> 21923718

The relationship between implant stability quotient values and implant insertion variables: a clinical study.

K-J Park1, J-Y Kwon, S-K Kim, S-J Heo, J-Y Koak, J-H Lee, S-J Lee, T-H Kim, M-J Kim.   

Abstract

The aim of this study was to determine whether resonance frequency analysis can be integrated into the routine clinical evaluation of the initial healing of dental implants. In addition, this study was designed to verify whether there was a correlation between implant stability quotient (ISQ) values, maximum insertion torque values, angular momentum and energy, and to evaluate the importance of different clinical factors in the determination of ISQ values and maximum insertion torque values at implant insertion. Two different implant designs of 81 dental implants in 41 patients were evaluated using ISQ values. Maximum insertion torque values were obtained during the placement procedure. Two new methods were used to calculate the angular momentum developed due to implant installation as well as the energy absorbed by the bone. A linear correlation between ISQ values and maximum insertion torque values at the initial implant surgery was found (P < 0·01). There was a correlation between ISQ values and angular momentum (P < 0·05), although ISQ values and energy did not show a significant linear correlation at the initial surgery (P > 0·05). There was a correlation between maximum insertion torque values, each part's angular momentum, and their energies during installation (P < 0·01). The sequence of the variables that influenced ISQ values was implant location, design, diameter, and gender of the patient. The results of this experiment suggest that both ISQ values and new methods to calculate angular momentum and energy can help to predict implant stability.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21923718     DOI: 10.1111/j.1365-2842.2011.02255.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  17 in total

1.  Influence of cortical bone anchorage on the primary stability of dental implants.

Authors:  Anne Kelly de Oliveira Nicolau Mantovani; Ivete Aparecida de Mattias Sartori; Luciana Reis Azevedo-Alanis; Rodrigo Tiossi; Flávia Noemy Gasparini Kiatake Fontão
Journal:  Oral Maxillofac Surg       Date:  2018-06-06

2.  Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study.

Authors:  David Chávarri-Prado; Aritza Brizuela-Velasco; Markel Diéguez-Pereira; Esteban Pérez-Pevida; Antonio Jiménez-Garrudo; Iratxe Viteri-Agustín; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo
Journal:  J Clin Exp Dent       Date:  2020-03-01

3.  Mini-implant stability at the initial healing period: a clinical pilot study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-07-24       Impact factor: 2.079

4.  Modified titanium implant as a gateway to the human body: the implant mediated drug delivery system.

Authors:  Young-Seok Park; Joo-Youn Cho; Shin-Jae Lee; Chee Il Hwang
Journal:  Biomed Res Int       Date:  2014-07-22       Impact factor: 3.411

5.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

6.  Effect of implant design on primary stability using torque-time curves in artificial bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Motohiro Munakata; Shohei Kasugai; Masahiko Ozeki
Journal:  Int J Implant Dent       Date:  2015-08-08

7.  Resonance frequency analysis of dental implants placed at the posterior maxilla varying the surface treatment only: A randomized clinical trial.

Authors:  Marcelo M Novellino; Newton Sesma; Piero R Zanardi; Dalva C Laganá
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-20       Impact factor: 3.932

8.  The impact of photofunctionalized gold nanoparticles on osseointegration.

Authors:  Yassir Elkhidir; Renfa Lai; Zhiqiang Feng
Journal:  Heliyon       Date:  2018-07-24

9.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

10.  Primary stability of self-drilling and self-tapping mini-implant in tibia of diabetes-induced rabbits.

Authors:  Jea-Beom Park; Eun-Young Kim; Janghyun Paek; Yoon-Ah Kook; Do-Min Jeong; Il-Sik Cho; Gerald Nelson
Journal:  Int J Dent       Date:  2014-05-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.