Literature DB >> 21915574

Comparative survival of uncemented acetabular components following primary total hip arthroplasty.

James L Howard1, Hilal Maradit Kremers, Youlonda A Loechler, Cathy D Schleck, William S Harmsen, Daniel J Berry, Miguel E Cabanela, Arlen D Hanssen, Mark W Pagnano, Robert T Trousdale, David G Lewallen.   

Abstract

BACKGROUND: Since their initial introduction in the early 1980s, uncemented acetabular components have become the preferred implant type for the majority of hip arthroplasties performed in the United States. The purpose of the present study was to compare differences in the survival of uncemented acetabular components following primary total hip arthroplasty.
METHODS: The study population included 7989 patients who had undergone 9584 primary total hip arthroplasties with twenty different types of uncemented acetabular components at the Mayo Clinic from January 1984 to December 2004. The overall rate of survival as well as the rate of survival free of revision for specific reasons (aseptic loosening, wear, osteolysis) were compared among the different components using age and sex-adjusted Cox proportional hazards regression models.
RESULTS: The risk of acetabular cup revision was significantly higher for beaded and hydroxyapatite-coated designs as compared with titanium wire mesh designs. Cross-linked polyethylene performed better than conventional polyethylene, but this finding did not reach significance. Elevated liners were associated with a significantly higher risk of cup revision due to aseptic loosening.
CONCLUSIONS: There are significant differences in the long-term survival of different types of uncemented acetabular components following total hip arthroplasty. The increased risk of revisions in the second decade after the initial total hip arthroplasty is a concern and is largely due to a steady increase in revisions because of polyethylene wear, osteolysis, and component loosening more than ten years after the time of the index arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21915574     DOI: 10.2106/JBJS.J.00195

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  24 in total

1.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

2.  Production, characterisation, and cytocompatibility of porous titanium-based particulate scaffolds.

Authors:  B J C Luthringer; F Ali; H Akaichi; F Feyerabend; T Ebel; R Willumeit
Journal:  J Mater Sci Mater Med       Date:  2013-06-27       Impact factor: 3.896

Review 3.  Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants.

Authors:  Eric Alexander Lewallen; Scott M Riester; Carolina A Bonin; Hilal Maradit Kremers; Amel Dudakovic; Sanjeev Kakar; Robert C Cohen; Jennifer J Westendorf; David G Lewallen; Andre J van Wijnen
Journal:  Tissue Eng Part B Rev       Date:  2014-12-18       Impact factor: 6.389

4.  Long-term results of the uncemented acetabular component in a primary total hip arthroplasty performed for protrusio acetabuli: a fifteen year median follow-up.

Authors:  Yaser M K Baghdadi; A Noelle Larson; Rafael J Sierra
Journal:  Int Orthop       Date:  2014-11-09       Impact factor: 3.075

5.  Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry.

Authors:  Elizabeth W Paxton; Maria C S Inacio; Robert S Namba; Rebecca Love; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

6.  Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs.

Authors:  Brett K J Kilb; Andrew P Kurmis; Michael Parry; Karen Sherwood; Paul Keown; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

7.  Risk of revision following total hip arthroplasty: metal-on-conventional polyethylene compared with metal-on-highly cross-linked polyethylene bearing surfaces: international results from six registries.

Authors:  Elizabeth Paxton; Guy Cafri; Leif Havelin; Susanna Stea; Francesc Pallisó; Stephen Graves; Daniel Hoeffel; Art Sedrakyan
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

8.  Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem.

Authors:  Robert M Urban; Deborah J Hall; Craig Della Valle; Markus A Wimmer; Joshua J Jacobs; Jorge O Galante
Journal:  J Bone Joint Surg Am       Date:  2012-10-17       Impact factor: 5.284

9.  Presence of interleukin-17C in the tissue around aseptic loosened implants.

Authors:  Changhe Hou; Yangchun Zhang; Shiming Yu; Ziqing Li; Qiyi Zhai; Zhanchun Li; Xibao Zhang; Jianhong Xiao; Puyi Sheng
Journal:  Int Orthop       Date:  2013-03-10       Impact factor: 3.075

10.  Outcomes of a metal-on-metal total hip replacement system.

Authors:  G S Matharu; K Theivendran; P B Pynsent; L Jeys; A M Pearson; D J Dunlop
Journal:  Ann R Coll Surg Engl       Date:  2014-10       Impact factor: 1.891

View more