Literature DB >> 21909812

Repeatability of nerve fiber layer thickness measurements in patients with glaucoma and without glaucoma using spectral-domain and time-domain OCT.

Marc Töteberg-Harms1, Veit Sturm, Pascal B Knecht, Jens Funk, Marcel N Menke.   

Abstract

BACKGROUND: The aim of this work is to assess the repeatability of spectral-domain-OCT (SD-OCT) retinal nerve fiber layer thickness (RNFL) thickness measurements in a non-glaucoma group and patients with glaucoma and to compare these results to conventional time-domain-OCT (TD-OCT).
METHODS: In a prospective, comparative, observational case-control study, 50 eyes of 25 non-glaucoma and 22 eyes of 11 patients with primary open angle glaucoma (POAG) were included. SD-OCT and TD-OCT circle scans were centered on the optic disc. In each eye, OCT scans were performed three times by two independent observers. RNFL thickness was measured in four quadrants around the optic disc. In addition, the overall mean RNFL thickness was assessed. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Inter-observer and inter-OCT repeatability was visualized by using Bland-Altman analysis.
RESULTS: Intra-observer repeatability for TD- OCT was good with an ICC(mean RNFL thickness) of 0.939 in non-glaucomas and 0.980 in glaucomatous eyes. For SD-OCT, intra-observer repeatability was higher with an ICC of 0.989 for non-glaucomas and 0.997 for glaucomatous eyes. COVs for TD-OCT ranged from 2.9-7.7% in non-glaucomas and from 6.0-13.3% in glaucoma patients. COVs for SD-OCT ranged from 0.3-1% in non-glaucomas and from 0.9-2.3% in glaucomatous eyes. COVs were influenced by various factors. In the glaucoma group, COVs were significantly higher (p < 0.001) compared to the non-glaucoma group. COVs increased by a mean of 5.1% when TD-OCT was used instead of SD-OCT (p < 0.001).
CONCLUSIONS: SD-OCT RNFL thickness measurements in healthy volunteers and glaucoma patients showed good intra- and inter-observer repeatability. Especially in glaucomatous eyes, repeatability of SD-OCT was superior to TD-OCT.

Entities:  

Mesh:

Year:  2011        PMID: 21909812     DOI: 10.1007/s00417-011-1811-9

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  36 in total

1.  Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography.

Authors:  E Z Blumenthal; J M Williams; R N Weinreb; C A Girkin; C C Berry; L M Zangwill
Journal:  Ophthalmology       Date:  2000-12       Impact factor: 12.079

2.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

3.  Effect of disease severity on the performance of Cirrus spectral-domain OCT for glaucoma diagnosis.

Authors:  Mauro T Leite; Linda M Zangwill; Robert N Weinreb; Harsha L Rao; Luciana M Alencar; Pamela A Sample; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-03-24       Impact factor: 4.799

4.  Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.

Authors:  Michelle L Gabriele; Hiroshi Ishikawa; Gadi Wollstein; Richard A Bilonick; Larry Kagemann; Maciej Wojtkowski; Vivek J Srinivasan; James G Fujimoto; Jay S Duker; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

5.  Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT.

Authors:  Marcel N Menke; Pascal Knecht; Veit Sturm; Simeon Dabov; Jens Funk
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-08-01       Impact factor: 4.799

6.  Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography.

Authors:  Seong Bae Park; Kyung Rim Sung; Sung Yong Kang; Kyung Ri Kim; Michael S Kook
Journal:  Arch Ophthalmol       Date:  2009-12

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes.

Authors:  Donald L Budenz; Robert T Chang; Xiangrun Huang; Robert W Knighton; James M Tielsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-07       Impact factor: 4.799

9.  [Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer].

Authors:  R Krist; E M Hoffmann; O Schwenn
Journal:  Ophthalmologe       Date:  2005-12       Impact factor: 1.059

10.  Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.

Authors:  Delia Bendschneider; Ralf P Tornow; Folkert K Horn; Robert Laemmer; Christopher W Roessler; Anselm G Juenemann; Friedrich E Kruse; Christian Y Mardin
Journal:  J Glaucoma       Date:  2010-09       Impact factor: 2.503

View more
  19 in total

1.  OCT Glaucoma Staging System: a new method for retinal nerve fiber layer damage classification using spectral-domain OCT.

Authors:  P Brusini
Journal:  Eye (Lond)       Date:  2017-08-04       Impact factor: 3.775

2.  Adjustment of the retinal angle in SD-OCT of glaucomatous eyes provides better intervisit reproducibility of peripapillary RNFL thickness.

Authors:  Kyungmoo Lee; Milan Sonka; Young H Kwon; Mona K Garvin; Michael D Abràmoff
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-18       Impact factor: 4.799

3.  Diagnostic capability of peripapillary retinal nerve fiber layer parameters in time-domain versus spectral-domain optical coherence tomography for assessing glaucoma in high myopia.

Authors:  Mei-Ching Teng; Yi-Chieh Poon; Kuo-Chi Hung; Hsueh-Wen Chang; Ing-Chou Lai; Jen-Chia Tsai; Pei-Wen Lin; Chien-Yun Wu; Chueh-Tan Chen; Pei-Chang Wu
Journal:  Int J Ophthalmol       Date:  2017-07-18       Impact factor: 1.779

Review 4.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

5.  Evaluating glaucoma damage: emerging imaging technologies.

Authors:  Tigran Kostanyan; Gadi Wollstein; Joel S Schuman
Journal:  Expert Rev Ophthalmol       Date:  2015-02-09

6.  Clinical-Evolutionary Staging System of Primary Open-Angle Glaucoma Using Optical Coherence Tomography.

Authors:  Alfonso Parra-Blesa; Alfredo Sanchez-Alberca; Jose Javier Garcia-Medina
Journal:  J Clin Med       Date:  2020-05-19       Impact factor: 4.241

7.  Optic nerve head slope-based quantitative parameters for identifying open-angle glaucoma on SPECTRALIS OCT images.

Authors:  Abdel-Razzak M Al-Hinnawi; Bassam O Al-Naami; Motasem M Al-Latayfeh
Journal:  Int Ophthalmol       Date:  2016-09-28       Impact factor: 2.031

8.  Glaucoma Diagnosis and Monitoring Using Advanced Imaging Technologies.

Authors:  Mitra Sehi; Shawn M Iverson
Journal:  US Ophthalmic Rev       Date:  2013

9.  OCT Variability Prevents Their Use as Robust Biomarkers in Multiple Sclerosis.

Authors:  Marta Para-Prieto; Raul Martin; Sara Crespo; Laura Mena-Garcia; Andres Valisena; Lisandro Cordero; Gloria Gonzalez Fernandez; Juan F Arenillas; Nieves Tellez; Jose Carlos Pastor
Journal:  Clin Ophthalmol       Date:  2021-05-14

10.  The Use of Spectral-Domain Optical Coherence Tomography to Detect Glaucoma Progression.

Authors:  Ricardo Y Abe; Carolina P B Gracitelli; Felipe A Medeiros
Journal:  Open Ophthalmol J       Date:  2015-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.