Literature DB >> 21908168

Clinical outcome of the metal-on-metal hybrid Corin Cormet 2000 hip resurfacing system: an up to 11-year follow-up study.

Thomas P Gross1, Fei Liu, Lee A Webb.   

Abstract

This report extends the follow-up for the largest center of the first multicenter US Food and Drug Administration investigational device exemption study on metal-on-metal hip resurfacing arthroplasty up to 11 years. A single surgeon performed 373 hip resurfacing arthroplasties using the hybrid Corin Cormet 2000 system. The Kaplan-Meier survivorship at 11 years was 93% when revision for any reason was used as an end point and 91% if radiographic failures were included. The clinical results demonstrate an acceptable failure rate with use of this system. Loosening of the cemented femoral components was the most common source of failure and occurred at all follow-up intervals. A learning curve that persisted for at least 200 cases was confirmed. All femoral neck fractures occurred before 6 months postoperatively. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21908168     DOI: 10.1016/j.arth.2011.06.019

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Survivorship and clinical outcome of Birmingham hip resurfacing: a minimum ten years' follow-up.

Authors:  Md Quamar Azam; Stephen McMahon; Gabrielle Hawdon; Sukesh Rao Sankineani
Journal:  Int Orthop       Date:  2015-03-31       Impact factor: 3.075

2.  Patients report improvement in quality of life and satisfaction after hip resurfacing arthroplasty.

Authors:  Wael A Rahman; Nelson V Greidanus; Alexander Siegmeth; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

Review 3.  Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates.

Authors:  S Sehatzadeh; K Kaulback; L Levin
Journal:  Ont Health Technol Assess Ser       Date:  2012-08-01

4.  The outcomes of hip resurfacing compared to standard primary total hip arthroplasty in Men.

Authors:  Kimona Issa; Amanda Palich; Tiffany Tatevossian; Bhaveen H Kapadia; Qais Naziri; Michael A Mont
Journal:  BMC Musculoskelet Disord       Date:  2013-05-08       Impact factor: 2.362

Review 5.  Metal-on-metal hip resurfacing in patients younger than 50 years: a retrospective analysis : 1285 cases, 12-year survivorship.

Authors:  Melissa D Gaillard; Thomas P Gross
Journal:  J Orthop Surg Res       Date:  2017-06-02       Impact factor: 2.359

6.  Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint.

Authors:  S C Scholes; B J Hunt; V M Richardson; D J Langton; E Smith; T J Joyce
Journal:  Bone Joint Res       Date:  2017-02       Impact factor: 5.853

7.  Risk of cancer with metal-on-metal hip replacements: population based study.

Authors:  Keijo T Mäkelä; Tuomo Visuri; Pekka Pulkkinen; Antti Eskelinen; Ville Remes; Petri Virolainen; Mika Junnila; Eero Pukkala
Journal:  BMJ       Date:  2012-07-25

8.  Reducing the failure rate of hip resurfacing in dysplasia patients: a retrospective analysis of 363 cases.

Authors:  Melissa D Gaillard; Thomas P Gross
Journal:  BMC Musculoskelet Disord       Date:  2016-06-07       Impact factor: 2.362

Review 9.  Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis.

Authors:  Aleksi Reito; Olli Lainiala; Petra Elo; Antti Eskelinen
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

10.  Poor 10-year survivorship of hip resurfacing arthroplasty.

Authors:  Matti Seppänen; Mikko Karvonen; Petri Virolainen; Ville Remes; Pekka Pulkkinen; Antti Eskelinen; Antti Liukas; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2016-10-19       Impact factor: 3.717

  10 in total