Literature DB >> 21905892

PEEK dental implants: a review of the literature.

Andreas Schwitalla1, Wolf-Dieter Müller.   

Abstract

The insertion of dental implants containing titanium can be associated with various complications (eg, hypersensitivity to titanium). The aim of this article is to evaluate whether there are existing studies reporting on PEEK (polyetheretherketone) as an alternative material for dental implants. A systematic literature search of PubMed until December 2010 yielded 3 articles reporting on dental implants made from PEEK. One article analyzed stress distribution in carbon fiber-reinforced PEEK (CFR-PEEK) dental implants by the 3-dimensional finite element method, demonstrating higher stress peaks due to a reduced stiffness compared to titanium. Two articles reported on investigations in mongrel dogs. The first article compared CFR-PEEK to titanium-coated CFR-PEEK implants, which were inserted into the femurs and evaluated after 4 and 8 weeks. The titanium-coated implants showed significantly higher bone-implant contact (BIC) rates. In a second study, implants of pure PEEK were inserted into the mandibles beside implants made from titanium and zirconia and evaluated after 4 months, where PEEK presented the lowest BIC. The existing articles reporting on PEEK dental implants indicate that PEEK could represent a viable alternative material for dental implants. However, further experimental studies on the chemical modulation of PEEK seem to be necessary, mainly to increase the BIC ratio and to minimize the stress distribution to the peri-implant bone.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21905892     DOI: 10.1563/AAID-JOI-D-11-00002

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  36 in total

1.  Polymer coatings based on sulfonated-poly-ether-ether-ketone films for implant dentistry applications.

Authors:  R S Brum; P R Monich; M C Fredel; G Contri; S D A S Ramoa; R S Magini; C A M Benfatti
Journal:  J Mater Sci Mater Med       Date:  2018-08-09       Impact factor: 3.896

2.  Bioactive amorphous magnesium phosphate-polyetheretherketone composite filaments for 3D printing.

Authors:  Prabaha Sikder; Jessica A Ferreira; Ehsan Akbari Fakhrabadi; Karla Z Kantorski; Matthew W Liberatore; Marco C Bottino; Sarit B Bhaduri
Journal:  Dent Mater       Date:  2020-05-22       Impact factor: 5.304

3.  Bonding of composite resins to PEEK: the influence of adhesive systems and air-abrasion parameters.

Authors:  Bogna Stawarczyk; Simon Taufall; Malgorzata Roos; Patrick R Schmidlin; Nina Lümkemann
Journal:  Clin Oral Investig       Date:  2017-06-24       Impact factor: 3.573

Review 4.  Customized Barrier Membrane (Titanium Alloy, Poly Ether-Ether Ketone and Unsintered Hydroxyapatite/Poly-l-Lactide) for Guided Bone Regeneration.

Authors:  Yilin Shi; Jin Liu; Mi Du; Shengben Zhang; Yue Liu; Hu Yang; Ruiwen Shi; Yuanyuan Guo; Feng Song; Yajun Zhao; Jing Lan
Journal:  Front Bioeng Biotechnol       Date:  2022-06-28

5.  Shear bond strength between veneering composite and PEEK after different surface modifications.

Authors:  Martin Rosentritt; Verena Preis; Michael Behr; Nuno Sereno; Carola Kolbeck
Journal:  Clin Oral Investig       Date:  2014-08-06       Impact factor: 3.573

6.  Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses.

Authors:  Simon Taufall; Marlis Eichberger; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-03-15       Impact factor: 3.573

Review 7.  Polyetheretherketone (PEEK) for medical applications.

Authors:  Ivan Vladislavov Panayotov; Valérie Orti; Frédéric Cuisinier; Jacques Yachouh
Journal:  J Mater Sci Mater Med       Date:  2016-06-03       Impact factor: 3.896

8.  Evaluation of the effects of different surface modification methods on the bond strength of high-performance polymers and resin matrix ceramics.

Authors:  Büşra Tosun; Nuran Yanıkoğlu
Journal:  Clin Oral Investig       Date:  2022-01-24       Impact factor: 3.573

9.  Stable sol-gel hydroxyapatite coating on zirconia dental implant for improved osseointegration.

Authors:  Jinyoung Kim; In-Gu Kang; Kwang-Hee Cheon; Sungmi Lee; Suhyung Park; Hyoun-Ee Kim; Cheol-Min Han
Journal:  J Mater Sci Mater Med       Date:  2021-06-30       Impact factor: 3.896

10.  A Perioperative Paradigm of Cranioplasty With Polyetheretherketone: Comprehensive Management for Preventing Postoperative Complications.

Authors:  Zhenghui He; Yuxiao Ma; Chun Yang; Jiyuan Hui; Qing Mao; Guoyi Gao; Jiyao Jiang; Junfeng Feng
Journal:  Front Surg       Date:  2022-03-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.