Literature DB >> 2189922

A multiple-frequency hydrophone calibration technique.

R A Smith1, D R Bacon.   

Abstract

A method is described for comparing the sensitivity of two hydrophones over the frequency range 1-15 MHz. This technique forms the basis for the dissemination of national ultrasonic standards in the U.K. over this frequency range. A reference hydrophone is placed in an ultrasonic field and then the device being calibrated is substituted and the two output voltages are compared. This substitution method utilizes a broadband ultrasonic field produced by nonlinear propagation. Thus it is possible to cover the whole frequency range with a single measurement on each hydrophone. The overall uncertainty in the intercomparison of two hydrophones increases from +/- 4.2% at 1 MHz to +/- 8.2% at 15 MHz (95% confidence level). The method has been compared with discrete-frequency substitution, time-delay spectrometry, and absolute calibrations using the National Physical Laboratory (NPL) Primary Standard Laser Interferometer. Various designs and sizes of hydrophones were compared, and agreement was within the combined random uncertainties for all the comparisons.

Mesh:

Year:  1990        PMID: 2189922     DOI: 10.1121/1.399191

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  7 in total

1.  Methods to calibrate the absolute receive sensitivity of single-element, focused transducers.

Authors:  Kyle T Rich; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-09       Impact factor: 1.840

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

4.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

5.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

6.  Automatic and robust calibration of optical detector arrays for biomedical diffuse optical spectroscopy.

Authors:  Michael A Mastanduno; Shudong Jiang; Roberta Diflorio-Alexander; Brian W Pogue; Keith D Paulsen
Journal:  Biomed Opt Express       Date:  2012-08-31       Impact factor: 3.732

7.  Pushing the boundaries of optoacoustic microscopy by total impulse response characterization.

Authors:  Markus Seeger; Dominik Soliman; Juan Aguirre; Gael Diot; Jakob Wierzbowski; Vasilis Ntziachristos
Journal:  Nat Commun       Date:  2020-06-09       Impact factor: 14.919

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.