Literature DB >> 21889347

The intraoperative gap difference (flexion gap minus extension gap) is altered by insertion of the trial femoral component.

Takehito Hananouchi1, Kengo Yamamoto, Wataru Ando, Kazumasa Fudo, Kenji Ohzono.   

Abstract

A Tensor/Balancer device has been recently developed in order to assess soft tissue balancing in total knee arthroplasty (TKA) under more physiological conditions. This device allows us to measure the joint gap with a trial femoral component in place with the patella reduced. The purpose of this study was to clarify whether the placement of the component changes the intraoperative gap difference (flexion gap distance minus extension gap distance). We prospectively investigated the extension (0°) and flexion (90°) gaps in 73 posterior-stabilized TKAs under 30 lb of joint distraction force. Then, we compared the gap difference with and without the trial femoral component in place. Our results showed that the intraoperative gap difference with the trial femoral component in place was larger than the intraoperative gap difference without the trial component (p=0.00003; with the trial component: mean 4.7 mm (standard deviation (SD): 3.0mm); without the trial component: mean 2.7 mm (SD: 3.3mm)). We consider that the change in gap difference with or without femoral component was caused by a relative difference in the elasticity and/or tightness of the soft tissue in extension versus flexion. Surgeons should be aware of this effect of the femoral component when considering intraoperative soft tissue balancing which leads to postoperative stability of the knee joint consequently.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21889347     DOI: 10.1016/j.knee.2011.08.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  15 in total

1.  Flexion and extension gaps created by the navigation-assisted gap technique show small acceptable mismatches and close mutual correlations.

Authors:  Dae-Hee Lee; Young-Soo Shin; Jin-Ho Jeon; Dong-Won Suh; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-27       Impact factor: 4.342

2.  Decreased extension gap and valgus alignment after implantation of total knee prosthesis in primary varus knees.

Authors:  Yukihide Minoda; Shigeru Nakagawa; Ryo Sugama; Tessyu Ikawa; Takahiro Noguchi; Masashi Hirakawa; Yoshio Matsui; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-14       Impact factor: 4.342

3.  Posterior reference guides do not always maintain the size of posterior femoral condyles in TKA.

Authors:  Yukihide Minoda; Shigekazu Mizokawa; Yoichi Ohta; Mitsuhiko Ikebuchi; Maki Itokazu; Kazumasa Yamamura; Suguru Nakamura; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-21       Impact factor: 4.342

4.  Tibiofemoral forces for the native and post-arthroplasty knee: relationship to maximal laxity through a functional arc of motion.

Authors:  William A Manning; Kanishka Ghosh; Alasdair Blain; Lee Longstaff; David John Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-31       Impact factor: 4.342

Review 5.  Is "symmetric" gap balancing still the gold standard in primary total knee arthroplasty?

Authors:  Salvatore Risitano; Pier Francesco Indelli
Journal:  Ann Transl Med       Date:  2017-08

6.  Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation.

Authors:  Takehito Hananouchi
Journal:  Int Orthop       Date:  2014-10-02       Impact factor: 3.075

7.  In vitro biomechanical evaluation of tri-condylar total knee arthroplasty with posterior release for restoration of full extension.

Authors:  Marehoshi Noboru; Tadashi Fujii; Jian-Qiang Mo; Ting Liang; Zong-Ping Luo; Yasuhito Tanaka
Journal:  J Orthop Translat       Date:  2017-02-16       Impact factor: 5.191

8.  Objective quantification of ligament balancing using VERASENSE in measured resection and modified gap balance total knee arthroplasty.

Authors:  Kyu-Jin Cho; Jong-Keun Seon; Won-Young Jang; Chun-Gon Park; Eun-Kyoo Song
Journal:  BMC Musculoskelet Disord       Date:  2018-07-27       Impact factor: 2.362

Review 9.  Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

Authors:  Young-Wan Moon; Hyun-Jung Kim; Hyeong-Sik Ahn; Chan-Deok Park; Dae-Hee Lee
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

10.  A gap balancing technique for adjusting the component gap in total knee arthroplasty using a navigation system.

Authors:  Hiroshi Takagi
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2020-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.