Literature DB >> 21883844

Prospective multi-centre study of adjustable single-incision mini-sling (Ajust(®) ) in the management of stress urinary incontinence in women: 1-year follow-up study.

Mohamed Abdel-Fattah1, Wael Agur, Mohamed Abdel-All, Karen Guerrero, Mohamed Allam, Alison Mackintosh, Alyaa Mostafa, Mohamed Yousef.   

Abstract

OBJECTIVES: To determine whether an adjustable single-incision mini-sling (SIMS, Ajust(®) ) is safe and effective in the management of female stress urinary incontinence (SUI) at 12 months follow-up. To determine whether it is feasible to be performed under local anesthesia (LA).
MATERIALS AND METHODS: The present study is a multicentre prospective cohort study in which 90 female patients underwent SIMS-Ajust(®) using a standardized insertion technique. The last 45 women were offered the procedure under LA. All patients completed their 12-month follow-up.
RESULTS: The patient-reported success rate, using Patient Global Impression of Improvement (PGI-I), was 80% at 12 months follow-up and a further 6% (n= 5) reported themselves to be 'improved'. In all, 32/45 (71%) patients agreed to undergo the procedure under LA while one patient required conversion to general anaesthetic. There was no organ damage or requirement for blood transfusion. Significantly lower rates of blood loss (P= 0.025) and postoperative voiding difficulties (P= 0.026) were seen in the LA group. The re-operation rate for SUI was 6% at 12 months.
CONCLUSIONS: SIMS (Ajust) appears to be a safe procedure, which is feasible under LA. SIMS (Ajust) have an 80% patient-reported success rate at 12 months follow-up.
© 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

Entities:  

Mesh:

Year:  2011        PMID: 21883844     DOI: 10.1111/j.1464-410X.2011.10471.x

Source DB:  PubMed          Journal:  BJU Int        ISSN: 1464-4096            Impact factor:   5.588


  16 in total

1.  Fixation of the Ajust minisling based upon cadaveric study.

Authors:  Petr Hubka; Ondrej Nanka; Alois Martan; Kamil Svabik; Rachid El-Haddad; Jaromir Masata
Journal:  Int Urogynecol J       Date:  2013-06-08       Impact factor: 2.894

2.  Multicentre randomized trial of the Ajust™ single-incision sling compared to the Align™ transobturator tape sling.

Authors:  Jordi Sabadell; Marta Palau-Gené; Eva Huguet; Anabel Montero-Armengol; Sabina Salicrú; Jose L Poza
Journal:  Int Urogynecol J       Date:  2016-12-05       Impact factor: 2.894

Review 3.  Comparison between three mini-sling surgical procedures and the traditional transobturator vaginal tape technique for female stress urinary incontinence.

Authors:  V Leanza; E Intagliata; A Leanza; F Ferla; G Leanza; R Vecchio
Journal:  G Chir       Date:  2014 Mar-Apr

4.  Long-term outcomes of the Ajust Adjustable Single-Incision Sling for the treatment of stress urinary incontinence.

Authors:  Gert Naumann; Thomas Hagemeier; Stefan Zachmann; Aktham Al-Ani; Stefan Albrich; Christine Skala; Rosa Laterza; Misti Linaberry; Heinz Koelbl
Journal:  Int Urogynecol J       Date:  2012-06-16       Impact factor: 2.894

5.  Clinical outcomes on tension-releasing suture appendage on single-incision sling devices for postoperative voiding dysfunction involving undue tape tension.

Authors:  Tsia-Shu Lo; Sandy Chua; Ling-Hong Tseng; Cheng-Yu Long; Chuan-Chi Kao; Wu-Chiao Hsieh
Journal:  Int Urogynecol J       Date:  2018-11-28       Impact factor: 2.894

6.  Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

Authors:  Jaromir Masata; Kamil Svabik; Karel Zvara; Petr Hubka; Ales Toman; Alois Martan
Journal:  Int Urogynecol J       Date:  2016-04-01       Impact factor: 2.894

7.  Short-term outcomes of Altis single-incision sling procedure for stress urinary incontinence: a prospective single-center study.

Authors:  Jorge Dias; Luís Xambre; Luís Costa; Pedro Costa; Luís Ferraz
Journal:  Int Urogynecol J       Date:  2014-03-06       Impact factor: 2.894

8.  Single-Incision Slings (SIS) - a New Option for the Surgical Treatment of Female Stress Urinary Incontinence.

Authors:  G Naumann; S Albrich; C Skala; R Laterza; H Kölbl
Journal:  Geburtshilfe Frauenheilkd       Date:  2012-02       Impact factor: 2.915

9.  Ajust single incision transobturator sling procedure for stress urinary incontinence: results after 1-year follow-up.

Authors:  Jean-Nicolas Cornu; Laurence Peyrat; Ariela Skurnik; Calin Ciofu; Vincent R Lucente; Francois Haab
Journal:  Int Urogynecol J       Date:  2012-05-15       Impact factor: 2.894

10.  Sexual function and quality of life following retropubic TVT and single-incision sling in women with stress urinary incontinence: results of a prospective study.

Authors:  Gert Naumann; Joscha Steetskamp; Mira Meyer; Rosa Laterza; Christine Skala; Stefan Albrich; Heinz Koelbl
Journal:  Arch Gynecol Obstet       Date:  2012-12-15       Impact factor: 2.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.