Literature DB >> 22584919

Ajust single incision transobturator sling procedure for stress urinary incontinence: results after 1-year follow-up.

Jean-Nicolas Cornu1, Laurence Peyrat, Ariela Skurnik, Calin Ciofu, Vincent R Lucente, Francois Haab.   

Abstract

INTRODUCTION AND HYPOTHESIS: Data on the Ajust, a new single-incision sling procedure for female stress urinary incontinence (SUI) management, remain scarce and limited to a 1-year follow-up. Our goal was to assess the efficacy of this procedure after a 1-year follow-up.
METHODS: This prospective evaluation involved 95 consecutive patients implanted with Ajust at a single centre. All patients had SUI on urodynamics due to urethral hypermobility, 33 % had preoperative overactive bladder (OAB) symptoms and none had detrusor overactivity. Ninety-two patients were treated on an outpatient basis, and 3 patients had general anaesthesia. Postoperative assessment was conducted at 1, 6, 12 months, and yearly thereafter. The main outcome measure was pad usage. Secondary parameters were self-reported SUI episodes, OAB symptoms, data of clinical examination, satisfaction using the Patient Global Impression of Improvement (PGI-I) scale, postoperative pain, and adverse events.
RESULTS: After a mean follow-up of 21 ± 6 months (12-32), 76 out of 95 patients used no pads or one dry security pad, showing a success rate of 80 %. Seventy-nine out of 95 patients had no more SUI-related leakage. Only 6 patients experienced late recurrence of SUI after 6 months' follow-up. Perioperative complications included 1 case of vaginal hematoma, 1 case of acute urinary retention, 2 cases of urinary tract infection, all managed conservatively. Half of the patients had no pain after day 1, free of medications. Late complications were vaginal erosion in 1 case, and pain during exertion in 2 cases.
CONCLUSIONS: The Ajust single incision transobturator sling is a safe and effective procedure, with durable results after 1 year.

Entities:  

Mesh:

Year:  2012        PMID: 22584919     DOI: 10.1007/s00192-012-1740-0

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  22 in total

1.  Long-term results with tension-free vaginal tape on mixed and stress urinary incontinence.

Authors:  Corinne Holmgren; Staffan Nilsson; Lars Lanner; Dan Hellberg
Journal:  Obstet Gynecol       Date:  2005-07       Impact factor: 7.661

Review 2.  Review article: Mid-urethral synthetic slings for female stress urinary incontinence.

Authors:  Eva D M Fong; Victor W Nitti
Journal:  BJU Int       Date:  2010-09       Impact factor: 5.588

3.  Short-term outcomes with the Ajust™ system: a new single incision sling for the treatment of stress urinary incontinence.

Authors:  Michele Meschia; Pietro Barbacini; Roberto Baccichet; Arturo Buonaguidi; Marco Maffiolini; Luisa Ricci; Chiara Braghin; Valentina Brusati; Chiara Dell'Utri; Lorenzo Spreafico
Journal:  Int Urogynecol J       Date:  2010-08-27       Impact factor: 2.894

4.  Validation of two global impression questionnaires for incontinence.

Authors:  Ilker Yalcin; Richard C Bump
Journal:  Am J Obstet Gynecol       Date:  2003-07       Impact factor: 8.661

Review 5.  An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction.

Authors:  Bernard T Haylen; Dirk de Ridder; Robert M Freeman; Steven E Swift; Bary Berghmans; Joseph Lee; Ash Monga; Eckhard Petri; Diaa E Rizk; Peter K Sand; Gabriel N Schaer
Journal:  Int Urogynecol J       Date:  2009-11-25       Impact factor: 2.894

6.  Burch colposuspension and tension-free vaginal tape in the management of stress urinary incontinence in women.

Authors:  A Liapis; P Bakas; G Creatsas
Journal:  Eur Urol       Date:  2002-04       Impact factor: 20.096

7.  Urinary incontinence in French women: prevalence, risk factors, and impact on quality of life.

Authors:  Andrea Lasserre; Camille Pelat; Violaine Guéroult; Thomas Hanslik; Emmanuel Chartier-Kastler; Thierry Blanchon; Calin Ciofu; Emmanuel D Montefiore; Fabián P Alvarez; Juliette Bloch
Journal:  Eur Urol       Date:  2009-04-10       Impact factor: 20.096

8.  Tension-free vaginal tape, suprapubic arc sling, and transobturator tape in the treatment of mixed urinary incontinence in women.

Authors:  Jae-Seung Paick; Seung-June Oh; Soo Woong Kim; Ja Hyeon Ku
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-06-13

9.  Intravaginal slingplasty (IVS): an ambulatory surgical procedure for treatment of female urinary incontinence.

Authors:  U Ulmsten; P Petros
Journal:  Scand J Urol Nephrol       Date:  1995-03

10.  The burden of lower urinary tract symptoms: evaluating the effect of LUTS on health-related quality of life, anxiety and depression: EpiLUTS.

Authors:  Karin S Coyne; Alan J Wein; Andrea Tubaro; Chris C Sexton; Christine L Thompson; Zoe S Kopp; Lalitha P Aiyer
Journal:  BJU Int       Date:  2009-04       Impact factor: 5.588

View more
  4 in total

1.  Multicentre randomized trial of the Ajust™ single-incision sling compared to the Align™ transobturator tape sling.

Authors:  Jordi Sabadell; Marta Palau-Gené; Eva Huguet; Anabel Montero-Armengol; Sabina Salicrú; Jose L Poza
Journal:  Int Urogynecol J       Date:  2016-12-05       Impact factor: 2.894

2.  Short-term outcomes of Altis single-incision sling procedure for stress urinary incontinence: a prospective single-center study.

Authors:  Jorge Dias; Luís Xambre; Luís Costa; Pedro Costa; Luís Ferraz
Journal:  Int Urogynecol J       Date:  2014-03-06       Impact factor: 2.894

3.  Minimally invasive treatment of female stress urinary incontinence with the adjustable single-incision sling system (AJUST ™) in an elderly and overweight population.

Authors:  Ralf Anding; Manuel Schoen; Ruth Kirschner-Hermanns; Christian Fisang; Stefan C Müller; Stefan Latz
Journal:  Int Braz J Urol       Date:  2017-01-27       Impact factor: 1.541

4.  Adjustable mini-sling compared with conventional mid-urethral slings in women with urinary incontinence: a 3-year follow-up of a randomized controlled trial.

Authors:  Vasileios Alexandridis; Martin Rudnicki; Ulf Jakobsson; Pia Teleman
Journal:  Int Urogynecol J       Date:  2019-06-20       Impact factor: 2.894

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.