Effect of hematocrit on accuracy of two point-of-care glucometers for use in dogs.

Amanda E H Paul1, Robert E Shiel, Florence Juvet, Carmel T Mooney, Caroline S Mansfield.   

Abstract

OBJECTIVE: To determine the effect of Hct on blood glucose readings of dogs obtained by use of 2 point-of-care (POC) blood glucometers and a laboratory analyzer. ANIMALS: 184 dogs, including 139 Greyhounds. PROCEDURES: Venous blood samples collected from 184 dogs with a range of Hcts (measured in EDTA-anticoagulated blood) were immediately analyzed with a handheld glucometer specifically developed for veterinary use and a glucometer developed for use in humans. The remainder of each blood sample was placed in fluoride oxalate tubes, and plasma glucose concentration was measured with a laboratory analyzer. Agreement between results for the POC glucometers and laboratory analyzer and effect of Hct on glucometer accuracy was assessed via regression analysis.
RESULTS: Significant differences were detected between results of the glucometers and the reference laboratory analyzer. The Hct affected the correlation between results for the glucometers and the laboratory analyzer. Deviations of the glucometers from the reference interval varied with Hct. The glucometer for veterinary use more closely correlated with the glucose concentration when Hct was within or above its reference interval. The glucometer for use in humans more closely approximated laboratory reference glucose concentrations in anemic dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Hct had a relevant impact on the correlation between whole blood and plasma glucose concentrations in dogs. Significant variations between results obtained with the 2 glucometers could be critical when interpreting blood glucose measurements or selecting a POC glucometer for an intensive care setting and precise glycemic control in critically ill dogs.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21879978     DOI: 10.2460/ajvr.72.9.1204

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  9 in total

1.  Accuracy of 5 Point-of-Care Glucometers in C57BL/6J Mice.

Authors:  Linnea A Morley; Thomas H Gomez; Julia L Goldman; Rene Flores; Mary A Robinson
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-01-01       Impact factor: 1.232

2.  Comparison of a human portable glucometer and an automated chemistry analyzer for measurement of blood glucose concentration in pet ferrets (Mustela putorius furo).

Authors:  Noémie M Summa; David Eshar; Bridget Lee-Chow; Sylvain Larrat; Dorothy C Brown
Journal:  Can Vet J       Date:  2014-09       Impact factor: 1.008

3.  Accuracy of Human and Veterinary Point-of-Care Glucometers for Use in Rhesus Macaques (Macaca mulatta), Sooty Mangabeys (Cercocebus atys), and Chimpanzees (Pan troglodytes).

Authors:  Elizabeth A Clemmons; Melissa I Stovall; Devon C Owens; Jessica A Scott; Amelia C Jones-Wilkes; Doty J Kempf; Kelly F Ethun
Journal:  J Am Assoc Lab Anim Sci       Date:  2016       Impact factor: 1.232

Review 4.  Hypoglycemia in dogs: Causes, management, and diagnosis.

Authors:  Olutunbi Idowu; Kathryn Heading
Journal:  Can Vet J       Date:  2018-06       Impact factor: 1.008

Review 5.  Monitoring methods for dogs and cats with diabetes mellitus.

Authors:  Audrey K Cook
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

6.  Comparison of 2 glucose analytical methodologies in immature Kemp's ridley sea turtles: dry chemistry of plasma versus point-of-care glucometer analysis of whole blood.

Authors:  Justin R Perrault; Michael D Arendt; Jeffrey A Schwenter; Julia L Byrd; Kathryn A Tuxbury; Nicole I Stacy
Journal:  J Vet Diagn Invest       Date:  2021-03-19       Impact factor: 1.279

7.  Pre-/analytical factors affecting whole blood and plasma glucose concentrations in loggerhead sea turtles (Caretta caretta).

Authors:  Patricia E Kunze; Justin R Perrault; Yu-Mei Chang; Charles A Manire; Samantha Clark; Nicole I Stacy
Journal:  PLoS One       Date:  2020-03-03       Impact factor: 3.240

8.  Comparison of glucose concentrations in canine whole blood, plasma, and serum measured with a veterinary point-of-care glucometer.

Authors:  Natalie D Suchowersky; Elizabeth A Carlson; Hollie P Lee; Ellen N Behrend
Journal:  J Vet Diagn Invest       Date:  2021-06-02       Impact factor: 1.569

9.  ISO-based assessment of accuracy and precision of glucose meters in dogs.

Authors:  Y Brito-Casillas; P Figueirinhas; J C Wiebe; L López-Ríos; D Pérez-Barreto; C Melián; A M Wägner
Journal:  J Vet Intern Med       Date:  2014-07-02       Impact factor: 3.333

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.