High-rangeability ultrasonic gas flowmeter for monitoring flare gas.

K S Mylvaganam1.   

Abstract

A transit-time ultrasonic gas flowmeter for high-rangeability requirements, such as those encountered in flare-gas flow-metering, is presented. The concept of ray rescue angle for the orientation of the ultrasonic transducers in single-beam transit-time ultrasonic flowmeters is introduced to overcome the problem of ultrasonic beam drift in high-velocity flows. To overcome problems associated with noise at high velocities, a chirp signal is used. To preserve the accuracy of the meter at low velocities near zero flow, a combination of chirp and continuous-wave signals is used to interrogate the flow. Overall system performance is presented, based on results from extensive wind-tunnel tests.

Year:  1989        PMID: 18284961     DOI: 10.1109/58.19144

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  1 in total

1.  FEA of CMUTs Suitable for Wide Gas Pressure Range Applications.

Authors:  Min-Chieh Ho; Mario Kupnik; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.