Literature DB >> 21870377

Inlet protein aggregation: a new mechanism for lubricating film formation with model synovial fluids.

J Fan1, C W Myant, R Underwood, P M Cann, A Hart.   

Abstract

This paper reports a fundamental study of lubricant film formation with model synovial fluid components (proteins) and bovine serum (BS). The objective was to investigate the role of proteins in the lubrication process. Film thickness was measured by optical interferometry in a ball-on-disc device (mean speed range of 2-60 mm/s). A commercial cobalt-chromium (CoCrMo) metal femoral head was used as the stationary component. The results for BS showed complex time-dependent behaviour, which was not representative of a simple fluid. After a few minutes sliding BS formed a thin adherent film of 10-20 nm, which was attributed to protein absorbance at the surface. This layer was augmented by a hydrodynamic film, which often increased at slow speeds. At the end of the test deposited surface layers of 20-50 nm were measured. Imaging of the contact showed that at slow speeds an apparent 'phase boundary' formed in the inlet just in front of the Hertzian zone. This was associated with the formation of a reservoir of high-viscosity material that periodically moved through the contact forming a much thicker film. The study shows that proteins play an important role in the film-forming process and current lubrication models do not capture these mechanisms.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21870377      PMCID: PMC4107775          DOI: 10.1177/0954411911401306

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  12 in total

Review 1.  Boundary lubrication in vivo.

Authors:  B A Hills
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

2.  The effect of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants.

Authors:  R Varano; J D Bobyn; J B Medley; S Yue
Journal:  Proc Inst Mech Eng H       Date:  2006-02       Impact factor: 1.617

3.  Conformational and adsorptive characteristics of albumin affect interfacial protein boundary lubrication: from experimental to molecular dynamics simulation approaches.

Authors:  Hsu-Wei Fang; Man-Ching Hsieh; Huei-Ting Huang; Cheng-Yen Tsai; Min-Hui Chang
Journal:  Colloids Surf B Biointerfaces       Date:  2008-10-19       Impact factor: 5.268

4.  Wear resistance of highly cross-linked and remelted polyethylenes after ion implantation and accelerated ageing.

Authors:  F J Medel; J A Puértolas
Journal:  Proc Inst Mech Eng H       Date:  2008-08       Impact factor: 1.617

Review 5.  Biological reaction to debris in relation to joint prostheses.

Authors:  P A Revell; N al-Saffar; A Kobayashi
Journal:  Proc Inst Mech Eng H       Date:  1997       Impact factor: 1.617

6.  Frictional heating of bearing materials tested in a hip joint wear simulator.

Authors:  Z Lu; H McKellop
Journal:  Proc Inst Mech Eng H       Date:  1997       Impact factor: 1.617

7.  Rheopexy of synovial fluid and protein aggregation.

Authors:  Katherine M N Oates; Wendy E Krause; Ronald L Jones; Ralph H Colby
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

8.  The effects of lubricant composition on in vitro wear testing of polymeric acetabular components.

Authors:  A Wang; A Essner; G Schmidig
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-01-15       Impact factor: 3.368

9.  Constituents and pH changes in protein rich hyaluronan solution affect the biotribological properties of artificial articular joints.

Authors:  T Kitano; G A Ateshian; V C Mow; Y Kadoya; Y Yamano
Journal:  J Biomech       Date:  2001-08       Impact factor: 2.712

10.  The association between metal ions from hip resurfacing and reduced T-cell counts.

Authors:  A J Hart; T Hester; K Sinclair; J J Powell; A E Goodship; L Pele; N L Fersht; J Skinner
Journal:  J Bone Joint Surg Br       Date:  2006-04
View more
  5 in total

Review 1.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

2.  Edge loading in metal-on-metal hips: low clearance is a new risk factor.

Authors:  Richard J Underwood; Angelos Zografos; Ritchie S Sayles; Alister Hart; Philippa Cann
Journal:  Proc Inst Mech Eng H       Date:  2012-03       Impact factor: 1.617

3.  Nanoparticle-Containing Hyaluronate Solution for Improved Lubrication of Orthopedic Ceramics.

Authors:  Weihua Li; Yingying Wang; Wenwen Li; Lei Liu; Xiao Wang; Shiyong Song
Journal:  Polymers (Basel)       Date:  2022-08-25       Impact factor: 4.967

4.  Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients.

Authors:  Zhiwei Cui; Yi-Xing Tian; Wen Yue; Lei Yang; Qunyang Li
Journal:  Sci Rep       Date:  2016-06-27       Impact factor: 4.379

5.  The Effect of Kinematic Conditions and Synovial Fluid Composition on the Frictional Behaviour of Materials for Artificial Joints.

Authors:  David Nečas; Martin Vrbka; Ivan Křupka; Martin Hartl
Journal:  Materials (Basel)       Date:  2018-05-10       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.