Literature DB >> 11448695

Constituents and pH changes in protein rich hyaluronan solution affect the biotribological properties of artificial articular joints.

T Kitano1, G A Ateshian, V C Mow, Y Kadoya, Y Yamano.   

Abstract

The relationship between the coefficient of friction and pH value or protein constituents of lubricating fluid, together with viscosity, were studied within a bearing surface model for artificial joint, ultra-high molecular weight polyethylene (UHMWPE) against stainless steel (SUS), using a mechanical spectrometer. Four lubricants were tested in this study: sodium hyaluronate (HA), HA with albumin, HA with gamma-globulin, and HA with (L)alpha-dipalmitoyl phosphatidylcholine ((L)alpha-DPPC). The coefficient of friction between UHMWPE and SUS in HA with albumin or HA with gamma-globulin varied from 0.035 to 0.070 depending on angular velocity and pH. The coefficient of friction in HA or HA with (L)alpha-DPPC varied from 0.023 to 0.045 depending on angular velocity and pH. The variation in pH for HA with albumin had a large effect on the coefficient of friction at low range of angular velocity with viscosity independence. The variation in pH for HA with gamma-globulin had a large effect on the coefficient of friction with viscosity dependence at high angular velocity. The addition of (L)alpha-DPPC showed a small effect on the coefficient of friction at low angular velocity. This study confirms that the presence of albumin in the lubricant promotes pH dependence and viscosity independence of the tribological properties at low speed while the presence of globulin promotes pH and viscosity independence at low speed and promotes pH and viscosity dependence at high speed in the lubrication of UHMWPE against SUS. This study supports the clinical hypothesis that the effect of constituents and pH changes in periprosthetic fluid for the lubrication is a clue toward resolving many complications after total joint replacement.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11448695     DOI: 10.1016/s0021-9290(01)00058-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Effect of protein concentrations of bovine serum albumin and γ-globulin on the frictional response of a cobalt-chromium femoral head.

Authors:  Cong-Truyen Duong; Jae-Hoon Lee; Younho Cho; Ju-Suk Nam; Hyong-Nyun Kim; Sang-Soo Lee; Seonghun Park
Journal:  J Mater Sci Mater Med       Date:  2012-03-10       Impact factor: 3.896

2.  Evaluation of J-initiation fracture toughness of ultra high molecular weight polyethylene used in total joint replacements.

Authors:  R Varadarajan; C M Rimnac
Journal:  Polym Test       Date:  2008-08-01       Impact factor: 4.282

3.  Inlet protein aggregation: a new mechanism for lubricating film formation with model synovial fluids.

Authors:  J Fan; C W Myant; R Underwood; P M Cann; A Hart
Journal:  Proc Inst Mech Eng H       Date:  2011-07       Impact factor: 1.617

4.  Tribological performance of the biological components of synovial fluid in artificial joint implants.

Authors:  Subir Ghosh; Dipankar Choudhury; Taposh Roy; Ali Moradi; H H Masjuki; Belinda Pingguan-Murphy
Journal:  Sci Technol Adv Mater       Date:  2015-07-28       Impact factor: 8.090

5.  Lipid Anchoring Improves Lubrication and Wear Resistance of the Collagen I Matrix.

Authors:  Hui Yuan; Hsiu-Wei Cheng; Laura LE Mears; Renliang Huang; Rongxin Su; Wei Qi; Zhimin He; Markus Valtiner
Journal:  Langmuir       Date:  2021-11-17       Impact factor: 3.882

6.  Nanoparticle-Containing Hyaluronate Solution for Improved Lubrication of Orthopedic Ceramics.

Authors:  Weihua Li; Yingying Wang; Wenwen Li; Lei Liu; Xiao Wang; Shiyong Song
Journal:  Polymers (Basel)       Date:  2022-08-25       Impact factor: 4.967

7.  The efficacy and safety of intra-articular injection of hyaluronic acid in the knee and physical therapy agents to treat Kashin-Beck disease: A prospective interventional study.

Authors:  Pinglin Yang; Xiong Guo; Xijing He; Quanjin Zang; Guoyu Wang; Peng Xu; Weizhuo Wang
Journal:  Exp Ther Med       Date:  2016-05-19       Impact factor: 2.447

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.