The effects of lubricant composition on in vitro wear testing of polymeric acetabular components.

A Wang1, A Essner, G Schmidig.   

Abstract

Lubricant composition is known to affect in vitro (simulator) wear of polymeric acetabular components. Clinical acetabular components, fabricated from both ultrahigh molecular weight polyethylene (UHMWPE) and polytetrafluoroethylene (PTFE), were tested against cobalt-chromium 32-mm ball heads, with the use of various lubricants, with different compositions and concentrations of bovine and calf serum as well as hyaluronic acid, in tests which lasted one million cycles. The type of proteins and their relative concentration in the lubricant affected the wear rate of both UHMWPE and PTFE. Increasing protein concentration reduced the UHMWPE wear rate but increased the PTFE wear rate. For a given total protein concentration, increasing the albumin/globulin (A/G) ratio led to a significant reduction in the wear rate for PTFE. A similar but smaller effect was found for UHMWPE. The relative wear-rate ratio between PTFE and UHMWPE depends on both the total protein concentration and the specific protein concentration (albumin/globulin ratio). The average clinical wear rates for both PTFE and UHMWPE and the average wear-rate ratios between them were reproduced when the serum lubricant contained total protein concentration and A/G ratio within normally observed physiological ranges. It is recommended that lubricants for simulator testing be standardized to control total protein content as well as albumin/globulin ratio. Copyright 2003 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14689495     DOI: 10.1002/jbm.b.10077

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  12 in total

1.  Effect of protein concentrations of bovine serum albumin and γ-globulin on the frictional response of a cobalt-chromium femoral head.

Authors:  Cong-Truyen Duong; Jae-Hoon Lee; Younho Cho; Ju-Suk Nam; Hyong-Nyun Kim; Sang-Soo Lee; Seonghun Park
Journal:  J Mater Sci Mater Med       Date:  2012-03-10       Impact factor: 3.896

2.  The use of self-mating PEEK as an alternative bearing material for cervical disc arthroplasty: a comparison of different simulator inputs and tribological environments.

Authors:  Tim Brown; Qi-Bin Bao
Journal:  Eur Spine J       Date:  2012-03-14       Impact factor: 3.134

3.  The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Authors:  Steven P Mell; Markus A Wimmer; Hannah J Lundberg
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

4.  Nanoscale adhesion, friction and wear studies of biomolecules on silane polymer-coated silica and alumina-based surfaces.

Authors:  Bharat Bhushan; Kwang Joo Kwak; Samit Gupta; Stephen C Lee
Journal:  J R Soc Interface       Date:  2008-11-04       Impact factor: 4.118

5.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

6.  Polyethylene wear particles induce TLR 2 upregulation in the synovial layer of mice.

Authors:  A C Paulus; J Frenzel; A Ficklscherer; B P Roßbach; C Melcher; V Jansson; S Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-11-19       Impact factor: 3.896

7.  Validation of a 3D CT method for measurement of linear wear of acetabular cups.

Authors:  Anneli Jedenmalm; Fritjof Nilsson; Marilyn E Noz; Douglas D Green; Ulf W Gedde; Ian C Clarke; Andreas Stark; Gerald Q Maguire; Michael P Zeleznik; Henrik Olivecrona
Journal:  Acta Orthop       Date:  2011-02-01       Impact factor: 3.717

8.  Inlet protein aggregation: a new mechanism for lubricating film formation with model synovial fluids.

Authors:  J Fan; C W Myant; R Underwood; P M Cann; A Hart
Journal:  Proc Inst Mech Eng H       Date:  2011-07       Impact factor: 1.617

9.  Tribological performance of the biological components of synovial fluid in artificial joint implants.

Authors:  Subir Ghosh; Dipankar Choudhury; Taposh Roy; Ali Moradi; H H Masjuki; Belinda Pingguan-Murphy
Journal:  Sci Technol Adv Mater       Date:  2015-07-28       Impact factor: 8.090

10.  Tribological investigation of diamond-like carbon coated micro-dimpled surface under bovine serum and osteoarthritis oriented synovial fluid.

Authors:  Subir Ghosh; Dipankar Choudhury; Taposh Roy; Azuddin Bin Mamat; H H Masjuki; Belinda Pingguan-Murphy
Journal:  Sci Technol Adv Mater       Date:  2015-05-14       Impact factor: 8.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.