Literature DB >> 21855392

Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D models.

Kanchana Rathnayaka1, Konstantin I Momot, Hansrudi Noser, Andrew Volp, Michael A Schuetz, Tony Sahama, Beat Schmutz.   

Abstract

Orthopaedic fracture fixation implants are increasingly being designed using accurate 3D models of long bones based on computer tomography (CT). Unlike CT, magnetic resonance imaging (MRI) does not involve ionising radiation and is therefore a desirable alternative to CT. This study aims to quantify the accuracy of MRI-based 3D models compared to CT-based 3D models of long bones. The femora of five intact cadaver ovine limbs were scanned using a 1.5 T MRI and a CT scanner. Image segmentation of CT and MRI data was performed using a multi-threshold segmentation method. Reference models were generated by digitising the bone surfaces free of soft tissue with a mechanical contact scanner. The MRI- and CT-derived models were validated against the reference models. The results demonstrated that the CT-based models contained an average error of 0.15 mm while the MRI-based models contained an average error of 0.23 mm. Statistical validation shows that there are no significant differences between 3D models based on CT and MRI data. These results indicate that the geometric accuracy of MRI based 3D models was comparable to that of CT-based models and therefore MRI is a potential alternative to CT for generation of 3D models with high geometric accuracy. Copyright Â
© 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21855392     DOI: 10.1016/j.medengphy.2011.07.027

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  22 in total

1.  Accurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot.

Authors:  Yuanzheng Gong; Danying Hu; Blake Hannaford; Eric J Seibel
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-02

2.  Potentialities and limitations of a database constructing three-dimensional virtual bone models.

Authors:  F Radetzki; T Mendel; H Noser; D Stoevesandt; M Röllinghoff; N Gutteck; K S Delank; D Wohlrab
Journal:  Surg Radiol Anat       Date:  2013-04-10       Impact factor: 1.246

3.  Can MRI accurately detect pilon articular malreduction? A quantitative comparison between CT and 3T MRI bone models.

Authors:  Shairah Radzi; Constantin Edmond Dlaska; Gary Cowin; Mark Robinson; Jit Pratap; Michael Andreas Schuetz; Sanjay Mishra; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2016-12

Review 4.  Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey.

Authors:  Amadeus C S de Alcântara; Israel Assis; Daniel Prada; Konrad Mehle; Stefan Schwan; Lucia Costa-Paiva; Munir S Skaf; Luiz C Wrobel; Paulo Sollero
Journal:  Materials (Basel)       Date:  2019-12-24       Impact factor: 3.623

5.  3DMR osseous reconstructions of the shoulder using a gradient-echo based two-point Dixon reconstruction: a feasibility study.

Authors:  Soterios Gyftopoulos; Avner Yemin; Thomas Mulholland; Michael Bloom; Pippa Storey; Christian Geppert; Michael P Recht
Journal:  Skeletal Radiol       Date:  2012-07-25       Impact factor: 2.199

6.  Computerised tomography vs magnetic resonance imaging for modeling of patient-specific instrumentation in total knee arthroplasty.

Authors:  Paul Stirling; Rejith Valsalan Mannambeth; Agustin Soler; Vineet Batta; Rajeev Kumar Malhotra; Yegappan Kalairajah
Journal:  World J Orthop       Date:  2015-03-18

7.  Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.

Authors:  Shairah Radzi; Gary Cowin; Mark Robinson; Jit Pratap; Andrew Volp; Michael A Schuetz; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2014-06

8.  Does 3DMR provide equivalent information as 3DCT for the pre-operative evaluation of adult Hip pain conditions of femoroacetabular impingement and Hip dysplasia?

Authors:  Kevin Yan; Yin Xi; Chayanit Sasiponganan; Joseph Zerr; Joel E Wells; Avneesh Chhabra
Journal:  Br J Radiol       Date:  2018-08-07       Impact factor: 3.039

9.  Evaluation of errors in measurements of infantile hip radiograph using digitally reconstructed radiograph from three-dimensional MRI.

Authors:  Daisuke Hamano; Kiyoshi Yoshida; Chikahisa Higuchi; Dai Otsuki; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  J Orthop       Date:  2019-05-09

10.  Comparison of cartilage and bone morphological models of the ankle joint derived from different medical imaging technologies.

Authors:  Gilda Durastanti; Alberto Leardini; Sorin Siegler; Stefano Durante; Alberto Bazzocchi; Claudio Belvedere
Journal:  Quant Imaging Med Surg       Date:  2019-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.