Literature DB >> 21841990

Load fatigue performance of conical implant-abutment connections.

Y L Seetoh1, Keson B Tan, E K Chua, H C Quek, Jack I Nicholls.   

Abstract

PURPOSE: Conical implant-abutment connections for platform switching have been recently introduced in implant systems. This study investigated the load fatigue performance of three conical abutment systems and their corresponding titanium and zirconia abutments.
MATERIALS AND METHODS: Regular-diameter implants of the Ankylos (AK), PrimaConnex (PC), and Straumann (ST) systems were tested with their corresponding titanium (Ti) and zirconia (Zr) abutments tightened to the recommended torque (n = 5 implant-abutment assemblies per group). A rotational load fatigue machine applied a sinusoidally varying tensile-compressive 21 N load to specimens at a 45-degree angle, producing an effective bending moment of 35 Ncm at a frequency of 10 Hz. The number of cycles to failure was recorded, with the upper limit set at 5 million cycles. Results were evaluated through analyses of variance.
RESULTS: Except for the ST Zr group, which showed no failures in four samples and one failure just below the screw head, and the AK Ti group, in which one sample was preserved without fracture, all groups experienced failure of at least one of the components, whether the abutment screw only, the abutment, and/or the implant neck. There were significant differences between systems. There was no difference between systems for the Ti abutments, and the ST group was significantly different from the AK and PC groups for the Zr abutments.
CONCLUSIONS: Ti conical abutments appear to have poorer load fatigue performance compared with earlier studies of external-hexagon connections. The load fatigue performance of Zr conical abutments varied and seemed to be highly system dependent. Many of the fractures in both the Ti and Zr abutment groups occurred within the implant, and retrieval would pose a significant clinical challenge. The clinician should weigh the mechanical, biologic, and esthetic considerations before selection of any implant system, connection type, or abutment material.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21841990

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

Review 2.  Removal of osseointegrated dental implants: a systematic review of explantation techniques.

Authors:  Margaux Roy; Lucie Loutan; Giovanni Garavaglia; Dena Hashim
Journal:  Clin Oral Investig       Date:  2019-11-15       Impact factor: 3.573

3.  Wear of Morse taper and external hexagon implant joints after abutment removal.

Authors:  Abraão M Prado; Jorge Pereira; Filipe S Silva; Bruno Henriques; Rubens M Nascimento; Cesar A M Benfatti; José López-López; Júlio C M Souza
Journal:  J Mater Sci Mater Med       Date:  2017-03-20       Impact factor: 3.896

4.  Selectable Implant Removal Methods due to Mechanical and Biological Failures.

Authors:  Jong-Bin Lee
Journal:  Case Rep Dent       Date:  2017-07-05

Review 5.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

6.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

7.  Tensile Bond Strength of Three Custom-made Tooth-Colored Implant Superstructures to Titanium Inserts.

Authors:  Mitra Zirak; Mahroo Vojdani; Amir Ali Reza Khaledi; Mitra Farzin
Journal:  J Dent (Shiraz)       Date:  2019-06

8.  Salvage of fractured abutment screw by transfer cap screw replacement (original study).

Authors:  Rawaa Y Al-Rawee; Fatima A Mohammad; Bashar A Tawfeeq
Journal:  Clin Case Rep       Date:  2019-05-10

9.  Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test.

Authors:  Caio Marques Martins; Elimário Venturin Ramos; Simone Kreve; Geraldo Alberto Pinheiro de Carvalho; Aline Batista Gonçalves Franco; Luís Guilherme Scavone de Macedo; Alecsandro de Moura Silva; Sérgio Candido Dias
Journal:  Dent Res J (Isfahan)       Date:  2019 Mar-Apr

10.  Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

Authors:  Hye Won Shim; Byoung-Eun Yang
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.