Literature DB >> 21835570

Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings.

Long Jiang Zhang1, Shengyong Wu, Mei Wang, Li Lu, Bo Chen, Lixin Jin, Jiandong Wang, Andrew C Larson, Guang Ming Lu.   

Abstract

PURPOSE: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors.
MATERIALS AND METHODS: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140kVp, 80kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured.
RESULTS: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P<0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P<0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r=0.913, P<0.001), hepatic blood flow (r=0.512, P=0.010), and hepatic blood volume (r=0.464, P=0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P<0.001).
CONCLUSIONS: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21835570     DOI: 10.1016/j.ejrad.2011.06.057

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

1.  Iodine quantification with dual-energy CT: phantom study and preliminary experience with VX2 residual tumour in rabbits after radiofrequency ablation.

Authors:  Y Li; G Shi; S Wang; S Wang; R Wu
Journal:  Br J Radiol       Date:  2013-07-24       Impact factor: 3.039

2.  Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.

Authors:  Stephan Skornitzke; Franziska Fritz; Philipp Mayer; Marco Koell; Jens Hansen; Gregor Pahn; Thilo Hackert; Hans-Ulrich Kauczor; Wolfram Stiller
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

3.  Hepatic arterial administration of sorafenib and iodized oil effectively attenuates tumor growth and intrahepatic metastasis in rabbit VX2 hepatocellular carcinoma model.

Authors:  Lin Zhang; Feng-Yong Liu; Jin-Xin Fu; Feng Duan; Qing-Sheng Fan; Mao-Qiang Wang
Journal:  Int J Clin Exp Pathol       Date:  2014-10-15

Review 4.  Quantitative dual-energy CT techniques in the abdomen.

Authors:  Giuseppe V Toia; Achille Mileto; Carolyn L Wang; Dushyant V Sahani
Journal:  Abdom Radiol (NY)       Date:  2021-09-01

5.  Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response.

Authors:  Jan Baxa; Alena Vondráková; Táňa Matoušková; Olga Růžičková; Bernhard Schmidt; Thomas Flohr; Martin Sedlmair; Jiří Ferda
Journal:  Eur Radiol       Date:  2014-06-04       Impact factor: 5.315

6.  Synthesized effective atomic numbers for commercially available dual-energy CT.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Kazushi Yokomachi; Chikako Fujioka; Tomoki Kimura; Kazuo Awai; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2020-02-21

Review 7.  Spectral detector CT applications in advanced liver imaging.

Authors:  Noor Fatima Majeed; Marta Braschi Amirfarzan; Christoph Wald; Jeremy R Wortman
Journal:  Br J Radiol       Date:  2021-05-28       Impact factor: 3.629

Review 8.  Visualization, imaging and new preclinical diagnostics in radiation oncology.

Authors:  Clemens C Cyran; Philipp M Paprottka; Michel Eisenblätter; Dirk A Clevert; Carsten Rist; Konstantin Nikolaou; Kirsten Lauber; Frederik Wenz; Daniel Hausmann; Maximilian F Reiser; Claus Belka; Maximilian Niyazi
Journal:  Radiat Oncol       Date:  2014-01-03       Impact factor: 3.481

9.  Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer.

Authors:  Xiaoliang Chen; Yanyan Xu; Jianghui Duan; Chuandong Li; Hongliang Sun; Wu Wang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

10.  Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging.

Authors:  Masahiko Aoki; Yoshihiro Takai; Yuichiro Narita; Katsumi Hirose; Mariko Sato; Hiroyoshi Akimoto; Hideo Kawaguchi; Yoshiomi Hatayama; Hiroyuki Miura; Shuichi Ono
Journal:  J Radiat Res       Date:  2014-05-14       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.