Literature DB >> 2182949

Real-time system for robust spectral parameter estimation in Doppler signal analysis.

C Di Giuliomaria1, M Capponi, T D'Alessio, R Sacco, E Zanette.   

Abstract

In assessing the level of stenosis in extracranial Doppler analysis, spectral analysis has until now been used qualitatively, for the most part. Owing to the many variables affecting the measurements (mainly noise level and instrument setting made subjectively by the operator), the reliability of the inferences on the degree of stenosis is not clearly definable. Under such conditions the need arises for algorithms and systems that can estimate spectral parameters with a higher degree of accuracy, to verify whether reliable inferences can indeed by made or if this technique is only a qualitative one. In the paper a real-time spectral analysis system is described. The system relies on a new spectral estimation algorithm which gives estimates with good robustness with respect to noise. Moreover, a clear measurement procedure which eliminates the many subjective factors affecting the estimates has also been proposed and used. The system has been evaluated with simulated signals and in clinical trials and has shown better performance than the commonly used commercial analysers.

Mesh:

Year:  1990        PMID: 2182949     DOI: 10.1007/BF02441678

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  Value of the spectral broadening index in continuous wave Doppler measurements.

Authors:  P F Wijn; P van der Sar; T H Gootzen; M H Tilmans; S H Skotnicki
Journal:  Med Biol Eng Comput       Date:  1987-07       Impact factor: 2.602

2.  Theoretical analysis of the CW doppler ultrasonic flowmeter.

Authors:  W R Brody; J D Meindl
Journal:  IEEE Trans Biomed Eng       Date:  1974-05       Impact factor: 4.538

3.  'Objective' algorithm for maximum frequency estimation in Doppler spectral analysers.

Authors:  T D'Alessio
Journal:  Med Biol Eng Comput       Date:  1985-01       Impact factor: 2.602

4.  Quantitative analysis of carotid artery Doppler spectral waveforms: diagnostic value of parameters.

Authors:  S E Rittgers; B M Thornhill; R W Barnes
Journal:  Ultrasound Med Biol       Date:  1983 May-Jun       Impact factor: 2.998

5.  Computer based pattern recognition of carotid arterial disease using pulsed Doppler ultrasound.

Authors:  F M Greene; K Beach; D E Strandness; G Fell; D J Phillips
Journal:  Ultrasound Med Biol       Date:  1982       Impact factor: 2.998

6.  Computer based pattern recognition of carotid artery Doppler signals for disease classification: prospective validation.

Authors:  Y E Langlois; F M Greene; G O Roederer; K A Jäger; D J Phillips; K W Beach; D E Strandness
Journal:  Ultrasound Med Biol       Date:  1984 Sep-Oct       Impact factor: 2.998

7.  Real-time calculation of ultrasonic pulsatility index.

Authors:  D T Gibbons; D H Evans; W W Barrie; P S Cosgriff
Journal:  Med Biol Eng Comput       Date:  1981-01       Impact factor: 2.602

8.  A critical study of ultrasound Doppler spectral analysis for detecting carotid disease.

Authors:  P M Brown; K W Johnston; M Kassam; R S Cobbold
Journal:  Ultrasound Med Biol       Date:  1982       Impact factor: 2.998

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.