Computer based pattern recognition of carotid artery Doppler signals for disease classification: prospective validation.

Y E Langlois, F M Greene, G O Roederer, K A Jäger, D J Phillips, K W Beach, D E Strandness.   

Abstract

A computer based pattern recognition method has been developed to classify the percent diameter reduction in nonoccluded internal carotid arteries. Using a combined B-mode/pulsed Doppler unit, the system utilizes spectral waveforms obtained from the low common and proximal internal carotid artery locations. The ECG-R wave is used as a time reference to synchronize the averaging of Doppler spectra from 20 heart cycles. An averaged waveform is generated and represents the spectral data from which features are extracted for analysis. A stepwise selection algorithm identifies a feature subset for partitioning the entire range of disease into two states, less than and greater than a decision point. Three such partitions are made, leading to the following categories: Normal, 1-20, 21-50 and 51-99% dia. reduction. A classifier was trained, tested prospectively against unknown data and the results compared to angiography. Of the 170 vessels tested, 141 (82%) were classified in the same category by angiography and the computer system. Agreement for each category was 93% (27/29) for the normals, 81.5% (44/54) for the 1-20% lesions, 78% (29/37) for the 21-50% lesions and 82% (41/50) for the 51-99% lesions. The computer method and angiography differed by more than one category in only one of the 170 tests. The level of agreement corrected for chance (Kappa +/- SE(K] was 0.769 +/- 0.039. Future efforts will be directed toward dividing classification of disease further (especially in the 51-99% category), developing a dedicated microprocessor for on-line analysis of the signals and using the system for prospective epidemiological studies of various populations.

Mesh:

Year:  1984        PMID: 6397885     DOI: 10.1016/0301-5629(84)90071-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Effect of ensemble averaging on amplitude and feature variabilities of Doppler spectrograms recorded in the lower limb arteries.

Authors:  L Allard; Y E Langlois; L G Durand; G O Roederer; G Cloutier
Journal:  Med Biol Eng Comput       Date:  1992-05       Impact factor: 2.602

2.  The effect of averaging cardiac Doppler spectrograms on the reduction of their amplitude variability.

Authors:  G Cloutier; L Allard; Z Guo; L G Durand
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

3.  Automatic detection of sounds and murmurs in patients with Ionescu-Shiley aortic bioprostheses.

Authors:  H L Baranek; H C Lee; G Cloutier; L G Durand
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

4.  Real-time system for robust spectral parameter estimation in Doppler signal analysis.

Authors:  C Di Giuliomaria; M Capponi; T D'Alessio; R Sacco; E Zanette
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

5.  Asymmetry of Doppler spectrum in stenosis differentiation.

Authors:  K Kaluzynski; A Tedgui
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602