Literature DB >> 6879832

Quantitative analysis of carotid artery Doppler spectral waveforms: diagnostic value of parameters.

S E Rittgers, B M Thornhill, R W Barnes.   

Abstract

Continuous-wave ultrasonic Doppler recordings made at the carotid bifurcation have been processed by spectrum analysis and off-line microprocessor software. Data reduction algorithms were defined and tested prior to incorporation in an integrated, hard-wired device. Subsequent analysis of waveforms in real-time provided measures of peak and mode frequencies and degree of spectral broadening. Correlation of results with 123 angiographically visualized internal carotid arteries showed that peak and mode frequencies generally increased with degree of stenosis while the systolic window decreased. Ratios of peak and mode frequencies in the proximal to the distal internal carotid artery and the systolic window at the distal internal carotid artery were retrospectively found to have diagnostic value with a combination of these three parameters providing the best overall accuracy.

Entities:  

Mesh:

Year:  1983        PMID: 6879832     DOI: 10.1016/0301-5629(83)90059-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  The effect of averaging cardiac Doppler spectrograms on the reduction of their amplitude variability.

Authors:  G Cloutier; L Allard; Z Guo; L G Durand
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

2.  Blood flow velocity waveform in the common carotid artery and its analysis in elderly subjects.

Authors:  I Nagatomo; M Nomaguchi; K Matsumoto
Journal:  Clin Auton Res       Date:  1992-06       Impact factor: 4.435

3.  Real-time system for robust spectral parameter estimation in Doppler signal analysis.

Authors:  C Di Giuliomaria; M Capponi; T D'Alessio; R Sacco; E Zanette
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

4.  Asymmetry of Doppler spectrum in stenosis differentiation.

Authors:  K Kaluzynski; A Tedgui
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

5.  Recurrent versus residual carotid stenosis. Incidence detected by Doppler ultrasound.

Authors:  R W Barnes; M L Nix; J P Wingo; B T Nichols
Journal:  Ann Surg       Date:  1986-06       Impact factor: 12.969

6.  Versatile microcomputer-based system for the capture, storage and processing of spectrum-analysed Doppler ultrasound blood flow signals.

Authors:  D R Prytherch; D H Evans
Journal:  Med Biol Eng Comput       Date:  1985-09       Impact factor: 2.602

7.  Computer processing of cardiac Doppler signals.

Authors:  A Heringa; J Alsters; J Hopman; I van Dam; O Daniëls
Journal:  Med Biol Eng Comput       Date:  1988-03       Impact factor: 2.602

8.  Noninvasive assessment of carotid artery disease.

Authors:  R W Barnes
Journal:  West J Med       Date:  1983-10
  8 in total