Literature DB >> 21828115

MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods.

Matthias Hofmann1, Ilja Bezrukov, Frederic Mantlik, Philip Aschoff, Florian Steinke, Thomas Beyer, Bernd J Pichler, Bernhard Schölkopf.   

Abstract

UNLABELLED: PET/MRI is an emerging dual-modality imaging technology that requires new approaches to PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC (MRAC): a basic MR image segmentation algorithm and a method based on atlas registration and pattern recognition (AT&PR).
METHODS: Eleven patients each underwent a whole-body PET/CT study and a separate multibed whole-body MRI study. The MR image segmentation algorithm uses a combination of image thresholds, Dixon fat-water segmentation, and component analysis to detect the lungs. MR images are segmented into 5 tissue classes (not including bone), and each class is assigned a default linear attenuation value. The AT&PR algorithm uses a database of previously aligned pairs of MRI/CT image volumes. For each patient, these pairs are registered to the patient MRI volume, and machine-learning techniques are used to predict attenuation values on a continuous scale. MRAC methods are compared via the quantitative analysis of AC PET images using volumes of interest in normal organs and on lesions. We assume the PET/CT values after CT-based AC to be the reference standard.
RESULTS: In regions of normal physiologic uptake, the average error of the mean standardized uptake value was 14.1% ± 10.2% and 7.7% ± 8.4% for the segmentation and the AT&PR methods, respectively. Lesion-based errors were 7.5% ± 7.9% for the segmentation method and 5.7% ± 4.7% for the AT&PR method.
CONCLUSION: The MRAC method using AT&PR provided better overall PET quantification accuracy than the basic MR image segmentation approach. This better quantification was due to the significantly reduced volume of errors made regarding volumes of interest within or near bones and the slightly reduced volume of errors made regarding areas outside the lungs.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21828115     DOI: 10.2967/jnumed.110.078949

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  94 in total

Review 1.  Hybrid MR-PET in Neuroimaging.

Authors:  S Bisdas; C Lá Fougere; U Ernemann
Journal:  Clin Neuroradiol       Date:  2015-07-31       Impact factor: 3.649

2.  Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI.

Authors:  Ryogo Minamimoto; Craig Levin; Mehran Jamali; Dawn Holley; Amir Barkhodari; Greg Zaharchuk; Andrei Iagaru
Journal:  Mol Imaging Biol       Date:  2016-10       Impact factor: 3.488

Review 3.  PET/MR in prostate cancer: technical aspects and potential diagnostic value.

Authors:  Michael Souvatzoglou; Matthias Eiber; Axel Martinez-Moeller; Sebastian Fürst; Konstantin Holzapfel; Tobias Maurer; Sibylle Ziegler; Stephan Nekolla; Markus Schwaiger; Ambros J Beer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-05-24       Impact factor: 9.236

Review 4.  Clinical and research applications of simultaneous positron emission tomography and MRI.

Authors:  F Fraioli; S Punwani
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

5.  Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging.

Authors:  David Izquierdo-Garcia; Stephen J Sawiak; Karin Knesaurek; Jagat Narula; Valentin Fuster; Joseph Machac; Zahi A Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-21       Impact factor: 9.236

6.  Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.

Authors:  Andrew P Leynes; Jaewon Yang; Florian Wiesinger; Sandeep S Kaushik; Dattesh D Shanbhag; Youngho Seo; Thomas A Hope; Peder E Z Larson
Journal:  J Nucl Med       Date:  2017-10-30       Impact factor: 10.057

7.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

8.  Accurate PET/MR quantification using time of flight MLAA image reconstruction.

Authors:  R Boellaard; M B M Hofman; O S Hoekstra; A A Lammertsma
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

9.  Defining optimal tracer activities in pediatric oncologic whole-body 18F-FDG-PET/MRI.

Authors:  Sergios Gatidis; Holger Schmidt; Christian la Fougère; Konstantin Nikolaou; Nina F Schwenzer; Jürgen F Schäfer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-26       Impact factor: 9.236

Review 10.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.