Literature DB >> 21826421

A preconcentration procedure for the determination of cadmium in biological material after on-line cloud point extraction.

Patrícia Xavier Baliza1, Luiz Augusto Martins Cardoso, Valfredo Azevedo Lemos.   

Abstract

In this paper, a method involving on-line preconcentration with cloud point extraction for the determination of cadmium in biological samples is presented. The procedure is based on the sorption of micelles containing Cd(II) ions and the reagent 4-(5'-bromo-2'-thiazolylazo)orcinol (Br-TAO) in a minicolumn packed with polyester. The surfactant Triton X-114 was used in the formation of micelles. After sorption, the Cd(II) ions were desorbed from the minicolumn with acid eluent and determined by flame atomic absorption spectrometry. Parameters influencing the cloud point extraction were studied. The method showed a detection limit of 0.5 μg l(-1) and an enhancement factor of 27. The accuracy was tested by determination of cadmium in certified reference materials (spinach leaves 1570a and tomato leaves 1573a) from the National Institute of Standards and Technology.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21826421     DOI: 10.1007/s10661-011-2277-2

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  13 in total

1.  On-line incorporation of cloud point extraction to flow injection analysis.

Authors:  Q Fang; M Du; C W Huie
Journal:  Anal Chem       Date:  2001-07-15       Impact factor: 6.986

2.  The efficiency of Amberlite XAD-4 resin loaded with 1-(2-pyridylazo)-2-naphthol in preconcentration and separation of some toxic metal ions by flame atomic absorption spectrometry.

Authors:  Aminul Islam; Mohammad Asaduddin Laskar; Akil Ahmad
Journal:  Environ Monit Assess       Date:  2010-05-28       Impact factor: 2.513

3.  Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS).

Authors:  Celal Duran; Ali Gundogdu; Volkan Numan Bulut; Mustafa Soylak; Latif Elci; Hasan Basri Sentürk; Mehmet Tüfekci
Journal:  J Hazard Mater       Date:  2006-12-16       Impact factor: 10.588

Review 4.  Determination of cadmium and lead in human biological samples by spectrometric techniques: a review.

Authors:  Valfredo Azevedo Lemos; Anaildes Lago de Carvalho
Journal:  Environ Monit Assess       Date:  2009-12-22       Impact factor: 2.513

5.  Simultaneous flow injection preconcentration of lead and cadmium using cloud point extraction and determination by atomic absorption spectrometry.

Authors:  Edson Luiz Silva; Paulo Dos Santos Roldan
Journal:  J Hazard Mater       Date:  2008-03-29       Impact factor: 10.588

6.  Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base.

Authors:  Berrin Topuz; Mustafa Macit
Journal:  Environ Monit Assess       Date:  2010-03-18       Impact factor: 2.513

7.  Optimization and determination of Cd (II) in different environmental water samples with dispersive liquid-liquid microextraction preconcentration combined with inductively coupled plasma optical emission spectrometry.

Authors:  Maryam Salahinejad; Fereydoon Aflaki
Journal:  Environ Monit Assess       Date:  2010-07-23       Impact factor: 2.513

8.  Multiple metal tolerance and biosorption of cadmium by Candida tropicalis isolated from industrial effluents: glutathione as detoxifying agent.

Authors:  Abdul Rehman; Muhammad Sohail Anjum
Journal:  Environ Monit Assess       Date:  2010-05-26       Impact factor: 2.513

9.  A pre-concentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry.

Authors:  S Saracoglu; M Soylak; D S Kacar Peker; L Elci; W N L dos Santos; V A Lemos; S L C Ferreira
Journal:  Anal Chim Acta       Date:  2006-05-27       Impact factor: 6.558

10.  Simultaneous determination of ultra trace amounts of lead and cadmium in food samples by adsorptive stripping voltammetry.

Authors:  Shahryar Abbasi; Kobra Khodarahmiyan; Freshteh Abbasi
Journal:  Food Chem       Date:  2011-02-22       Impact factor: 7.514

View more
  1 in total

1.  Determination of ultra-trace amounts of cadmium by ET-AAS after column preconcentration with a new sorbent of modified MWCNTs.

Authors:  Mohadeseh Madadizadeh; Mohammad Ali Taher; Hamid Ashkenani
Journal:  Environ Monit Assess       Date:  2012-09-01       Impact factor: 2.513

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.