Literature DB >> 18456398

Simultaneous flow injection preconcentration of lead and cadmium using cloud point extraction and determination by atomic absorption spectrometry.

Edson Luiz Silva1, Paulo Dos Santos Roldan.   

Abstract

A flow injection (FI) micelle-mediated separation/preconcentration procedure for the determination of lead and cadmium by flame atomic absorption spectrometry (FAAS) has been proposed. The analytes reacted with 1-(2-thiazolylazo)-2-naphthol (TAN) to form hydrophobic chelates, which were extracted into the micelles of 0.05% (w/v) Triton X-114 in a solution buffered at pH 8.4. In the preconcentration stage, the micellar solution was continuously injected into a flow system with four mini-columns packed with cotton, glass wool, or TNT compresses for phase separation. The analytes-containing micelles were eluted from the mini-columns by a stream of 3molL(-1) HCl solution and the analytes were determined by FAAS. Chemical and flow variables affecting the preconcentration of the analytes were studied. For 15mL of preconcentrated solution, the enhancement factors varied between 15.1 and 20.3, the limits of detection were approximately 4.5 and 0.75microgL(-1) for lead and cadmium, respectively. For a solution containing 100 and 10microgL(-1) of lead and cadmium, respectively, the R.S.D. values varied from 1.6 to 3.2% (n=7). The accuracy of the preconcentration system was evaluated by recovery measurements on spiked water samples. The method was susceptible to matrix effects, but these interferences were minimized by adding barium ions as masking agent in the sample solutions, and recoveries from spiked sample varied in the range of 95.1-107.3%.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18456398     DOI: 10.1016/j.jhazmat.2008.03.100

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  9 in total

1.  Cloud point extraction for the preconcentration of palladium and lead in environmental samples and determination by flow injection flame atomic absorption spectrometry: CPE for preconcentration of Pd and Pb by FI-FAAS.

Authors:  Dilek Bakircioglu
Journal:  Environ Sci Pollut Res Int       Date:  2012-01-25       Impact factor: 4.223

2.  The use of silica gel modified with allyl 6-methyl-4-phenyl-2-thioxo-1,2,3,4-tetrahydropyrimidine-5-carboxylate for selective separation and preconcentration of lead in environmental samples.

Authors:  Fatemeh Sabermahani; Zahra Hassani; Mahboobeh Faramarzpoor
Journal:  Environ Monit Assess       Date:  2012-10-06       Impact factor: 2.513

3.  A preconcentration procedure for the determination of cadmium in biological material after on-line cloud point extraction.

Authors:  Patrícia Xavier Baliza; Luiz Augusto Martins Cardoso; Valfredo Azevedo Lemos
Journal:  Environ Monit Assess       Date:  2011-08-09       Impact factor: 2.513

4.  Solid Phase Extraction of Trace Elements in Waterand Tissue Samples on a Mini Column with Diphenylcarbazone Impregnated Nano-TiO2 and Their Determination by Inductively Coupled Plasma Optical Emission Spectrometry.

Authors:  Sıtkı Baytak; Zikri Arslan
Journal:  Clean (Weinh)       Date:  2015-06-01       Impact factor: 1.770

5.  Environmental materials for remediation of soils contaminated with lead and cadmium using maize (Zea mays L.) growth as a bioindicator.

Authors:  Yu Shi; Zhanbin Huang; Xiujie Liu; Suheryani Imran; Licheng Peng; Rongji Dai; Yulin Deng
Journal:  Environ Sci Pollut Res Int       Date:  2015-11-25       Impact factor: 4.223

6.  Selective preconcentration separation of Hg(ii) and Cd(ii) from water, fish muscles, and cucumber samples using recycled aluminum adsorbents.

Authors:  A B Abdallah; Ehab A Abdelrahman; Adel M Youins; Wesam A Ibrahim; Magdi E Khalifa
Journal:  RSC Adv       Date:  2022-03-10       Impact factor: 3.361

7.  Selective cloud point extraction for the spectrophotometric determination of cetylpyridinium chloride in pharmaceutical formulations.

Authors:  Ali Reza Zarei; Hayedeh Bagheri Sadeghi; Samira Abedin
Journal:  Iran J Pharm Res       Date:  2013       Impact factor: 1.696

8.  Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples.

Authors:  Zarrin Es'haghi; Hasan Ali Hoseini; Saeed Mohammadi-Nokhandani; Javad Ebrahimi
Journal:  J Adv Res       Date:  2013-11-20       Impact factor: 10.479

9.  Modifier-Free Microfluidic Electrochemical Sensor for Heavy-Metal Detection.

Authors:  Liu-Liu Shen; Gui-Rong Zhang; Wei Li; Markus Biesalski; Bastian J M Etzold
Journal:  ACS Omega       Date:  2017-08-16
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.