Literature DB >> 21819684

Use of an implantable loop recorder in the investigation of arrhythmias in adult captive chimpanzees (Pan troglodytes).

Michael L Lammey1, Raven Jackson, John J Ely, D Rick Lee, Meg M Sleeper.   

Abstract

Cardiovascular disease in general, and cardiac arrhythmias specifically, is common in great apes. However, the clinical significance of arrhythmias detected on short-duration electrocardiograms is often unclear. Here we describe the use of an implantable loop recorder to evaluate cardiac rhythms in 4 unanesthetized adult chimpanzees (Pan troglodytes), 1 with a history of possible syncope and 3 with the diagnosis of multiform ventricular ectopy (ventricular premature complexes) and cardiomyopathy. The clinical significance of ventricular ectopy was defined further by using the implantable loop recorder. Arrhythmia was ruled out as a cause of collapse in the chimpanzee that presented with possible syncope because the implantable loop recorder demonstrated normal sinus rhythm during a so-called syncopal event. This description is the first report of the use of an implantable loop recorder to diagnose cardiac arrhythmias in an unanesthetized great ape species.

Entities:  

Mesh:

Year:  2011        PMID: 21819684      PMCID: PMC3060426     

Source DB:  PubMed          Journal:  Comp Med        ISSN: 1532-0820            Impact factor:   0.982


  18 in total

1.  Electrocardiogram abnormalities in captive chimpanzees (Pan troglodytes).

Authors:  Cynthia J Doane; D Rick Lee; Meg M Sleeper
Journal:  Comp Med       Date:  2006-12       Impact factor: 0.982

2.  Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators.

Authors:  A J Moss; W J Hall; D S Cannom; J P Daubert; S L Higgins; H Klein; J H Levine; S Saksena; A L Waldo; D Wilber; M W Brown; M Heo
Journal:  N Engl J Med       Date:  1996-12-26       Impact factor: 91.245

3.  Diffuse myocardial fibrosis and congestive heart failure in an adult male chimpanzee.

Authors:  J F Hansen; P L Alford; M E Keeling
Journal:  Vet Pathol       Date:  1984-09       Impact factor: 2.221

4.  Use of an implantable loop recorder to investigate syncope in a cat.

Authors:  R Willis; K McLeod; J Cusack; P Wotton
Journal:  J Small Anim Pract       Date:  2003-04       Impact factor: 1.522

5.  The clinical impact of implantable loop recorders in patients with syncope.

Authors:  David J Farwell; Nick Freemantle; Neil Sulke
Journal:  Eur Heart J       Date:  2005-11-28       Impact factor: 29.983

6.  Use of transtelephonic electrocardiographic monitoring in children with suspected arrhythmias.

Authors:  L Houyel; A Fournier; S Centazzo; A Davignon
Journal:  Can J Cardiol       Date:  1992-09       Impact factor: 5.223

7.  Diagnosis and treatment of pulmonary arterial hypertension and atrial fibrillation in an adult chimpanzee (Pan troglodytes).

Authors:  Michael L Lammey; Cynthia J Doane; Andrew Gigliotti; D Rick Lee; Meg M Sleeper
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-09       Impact factor: 1.232

8.  Cardiodynamics in the rhesus macaque during dissociative anesthesia.

Authors:  J L Booker; H H Erickson; E L Fitzpatrick
Journal:  Am J Vet Res       Date:  1982-04       Impact factor: 1.156

9.  Sudden cardiac death in 13 captive chimpanzees (Pan troglodytes).

Authors:  Michael L Lammey; D Rick Lee; John J Ely; Meg M Sleeper
Journal:  J Med Primatol       Date:  2008-02       Impact factor: 0.667

10.  Heart disease is common in humans and chimpanzees, but is caused by different pathological processes.

Authors:  Nissi Varki; Dan Anderson; James G Herndon; Tho Pham; Christopher J Gregg; Monica Cheriyan; James Murphy; Elizabeth Strobert; Jo Fritz; James G Else; Ajit Varki
Journal:  Evol Appl       Date:  2009-02       Impact factor: 5.183

View more
  2 in total

1.  Chronic diseases in captive geriatric female Chimpanzees (Pan troglodytes).

Authors:  Elizabeth A Nunamaker; D Rick Lee; Michael L Lammey
Journal:  Comp Med       Date:  2012-04       Impact factor: 0.982

2.  Use of an Implantable Loop Recorder in a Chimpanzee (Pan troglodytes) to Monitor Cardiac Arrhythmias and Assess the Effects of Acupuncture and Laser Therapy.

Authors:  Elizabeth R Magden; Meg M Sleeper; Stephanie J Buchl; Rebekah A Jones; Erica J Thiele; Gregory K Wilkerson
Journal:  Comp Med       Date:  2016-02       Impact factor: 0.982

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.