Literature DB >> 2181766

A validation study on the reproducibility of transcranial Doppler velocimetry.

H Maeda1, H Etani, N Handa, M Tagaya, N Oku, B H Kim, M Naka, N Kinoshita, T Nukada, R Fukunaga.   

Abstract

The transcranial Doppler method for the measurement of intracranial arterial blood flow velocity is a useful noninvasive technique with a number of applications. The present study validated the reproducibility of this method for repeated measurements of flow velocity in the middle cerebral and basilar arteries. Fifteen healthy volunteers were studied. Measurements were made twice by one examiner and once by another in a single day and again by the first examiner on another day. The reproducibility was evaluated by calculating the correlation coefficient (r) and the coefficient of variation (CV) of the difference between the values obtained from each pair of measurements. Although depending on the examiner, the time interval between the examinations and the vessels studied some differences were noted in the reproducibility, both the r (0.69-0.95) and CV (6.7%-19.5%) values in the whole study were good enough to warrant the applicability of this method for the repeated measurements of the intracranial arterial blood flow velocity in future studies.

Mesh:

Year:  1990        PMID: 2181766     DOI: 10.1016/0301-5629(90)90080-v

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  14 in total

Review 1.  Transcranial Doppler ultrasonography monitoring of cerebral hemodynamics during performance of cognitive tasks: a review.

Authors:  N Stroobant; G Vingerhoets
Journal:  Neuropsychol Rev       Date:  2000-12       Impact factor: 7.444

2.  Inter observer variability of the transcranial Doppler ultrasound technique: impact of lack of practice on the accuracy of measurement.

Authors:  Q Shen; J Stuart; B Venkatesh; J Wallace; J Lipman
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

3.  New ways of performing in vivo flow velocity measurements in the basilar artery.

Authors:  J Ravensbergen; M Tarnawski; E M Vriens; B Hillen; C G Caro; A C Van Huffelen
Journal:  Neuroradiology       Date:  1996-01       Impact factor: 2.804

4.  Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound.

Authors:  J N Stember; K L Terilli; E Perez; M Megjhani; C A Cooper; S Jambawalikar; S Park
Journal:  J Digit Imaging       Date:  2020-08       Impact factor: 4.056

5.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

6.  Cerebral hemodynamics in ocular hypertension.

Authors:  Cengiz Akarsu; Yasemin Karadeniz Bilgili; Birsen Unal; Pelin Taner; Ahmet Ergin; Simay Altan Kara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-10-27       Impact factor: 3.117

7.  Feasibility trial for primary stroke prevention in children with sickle cell anemia in Nigeria (SPIN trial).

Authors:  Najibah A Galadanci; Shehu Umar Abdullahi; Leah D Vance; Abdulkadir Musa Tabari; Shehi Ali; Raymond Belonwu; Auwal Salihu; Aisha Amal Galadanci; Binta Wudil Jibir; Halima Bello-Manga; Kathleen Neville; Fenella J Kirkham; Yu Shyr; Sharon Phillips; Brittany V Covert; Adetola A Kassim; Lori C Jordan; Muktar H Aliyu; Michael R DeBaun
Journal:  Am J Hematol       Date:  2017-06-15       Impact factor: 10.047

8.  The accuracy of transcranial Doppler to detect vasospasm in patients with aneurysmal subarachnoid hemorrhage.

Authors:  L Mascia; L Fedorko; K terBrugge; C Filippini; M Pizzio; V M Ranieri; M C Wallace
Journal:  Intensive Care Med       Date:  2003-05-28       Impact factor: 17.440

9.  Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review.

Authors:  P H Raboel; J Bartek; M Andresen; B M Bellander; B Romner
Journal:  Crit Care Res Pract       Date:  2012-06-08

10.  Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement.

Authors:  Paula Muñoz Venturelli; Alejandro M Brunser; Javier Gaete; Sergio Illanes; Javiera López; Verónica V Olavarría; Andrés Reccius; Pablo Brinck; Francisca González; Gabriel Cavada; Pablo M Lavados
Journal:  J Med Ultrasound       Date:  2017-01-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.