L Mascia1, L Fedorko, K terBrugge, C Filippini, M Pizzio, V M Ranieri, M C Wallace. 1. Dipartimento di Discipline Medico-Chirurgiche, Sezione di Anestesiologia e Rianimazione, Ospedale S. Giovanni Battista, Università di Torino, Corso Dogliotti 14, 10126, Torino, Italy. luciana.mascia@unito.it
Abstract
OBJECTIVES: To examine the accuracy of transcranial Doppler to detect cerebral vasospasm in a patient population with aneurysmal subarachnoid hemorrhage. DESIGN: Prospective blind comparison of transcranial Doppler with cerebral angiography. Diagnostic accuracy of transcranial Doppler was assessed using receiver operating characteristic (ROC) analysis and likelihood ratios. Sensitivity and specificity were calculated using directly measured middle cerebral artery diameter as reference standard. SETTING: Intensive Care Unit of a large university teaching hospital. PATIENTS AND PARTICIPANTS: Twenty-two patients with subarachnoid hemorrhage were included. Patients underwent angiography on admission and after 8 days to diagnose vasospasm and were defined as having clinical vasospasm, angiographic vasospasm, or no vasospasm. MEASUREMENTS AND RESULTS: Sensitivity and specificity were 1.00 and 0.75 for angiographic vasospasm and both equal to 1.00 for clinical vasospasm diagnosis. A transcranial Doppler mean velocity threshold value of 100 cm/s for angiographic vasospasm and 160 cm/s for clinical vasospasm detection were chosen by ROC analysis. CONCLUSIONS: A Transcranial Doppler mean velocity threshold of 160 cm/s, calculated by the ROC analysis, accurately detects clinical vasospasm. A daily transcranial Doppler examination performed by a trained operator should be routinely used to provide early identification of patients at high risk and to orient therapeutic decisions.
OBJECTIVES: To examine the accuracy of transcranial Doppler to detect cerebral vasospasm in a patient population with aneurysmal subarachnoid hemorrhage. DESIGN: Prospective blind comparison of transcranial Doppler with cerebral angiography. Diagnostic accuracy of transcranial Doppler was assessed using receiver operating characteristic (ROC) analysis and likelihood ratios. Sensitivity and specificity were calculated using directly measured middle cerebral artery diameter as reference standard. SETTING: Intensive Care Unit of a large university teaching hospital. PATIENTS AND PARTICIPANTS: Twenty-two patients with subarachnoid hemorrhage were included. Patients underwent angiography on admission and after 8 days to diagnose vasospasm and were defined as having clinical vasospasm, angiographic vasospasm, or no vasospasm. MEASUREMENTS AND RESULTS: Sensitivity and specificity were 1.00 and 0.75 for angiographic vasospasm and both equal to 1.00 for clinical vasospasm diagnosis. A transcranial Doppler mean velocity threshold value of 100 cm/s for angiographic vasospasm and 160 cm/s for clinical vasospasm detection were chosen by ROC analysis. CONCLUSIONS: A Transcranial Doppler mean velocity threshold of 160 cm/s, calculated by the ROC analysis, accurately detects clinical vasospasm. A daily transcranial Doppler examination performed by a trained operator should be routinely used to provide early identification of patients at high risk and to orient therapeutic decisions.
Authors: M R Mayberg; H H Batjer; R Dacey; M Diringer; E C Haley; R C Heros; L L Sternau; J Torner; H P Adams; W Feinberg Journal: Stroke Date: 1994-11 Impact factor: 7.914
Authors: Jose I Suarez; Adnan I Qureshi; Abutaher B Yahia; Parak D Parekh; Rafael J Tamargo; Michael A Williams; John A Ulatowski; Daniel F Hanley; Alexander Y Razumovsky Journal: Crit Care Med Date: 2002-06 Impact factor: 7.598
Authors: T Itoh; M Matsumoto; N Handa; H Maeda; H Hougaku; H Hashimoto; H Etani; Y Tsukamoto; T Kamada Journal: Stroke Date: 1993-08 Impact factor: 7.914
Authors: Edward Abraham; Peter Andrews; Massimo Antonelli; Laurent Brochard; Christian Brun-Buisson; Geoffrey Dobb; Jean-Yves Fagon; Johan Groeneveld; Jordi Mancebo; Philipp Metnitz; Stefano Nava; Michael Pinsky; Peter Radermacher; Marco Ranieri; Christian Richard; Robert Tasker; Benoit Vallet Journal: Intensive Care Med Date: 2004-06-15 Impact factor: 17.440
Authors: Arturo Chieregato; Giuseppe Sabia; Alessandra Tanfani; Christian Compagnone; Fernanda Tagliaferri; Luigi Targa Journal: Intensive Care Med Date: 2006-06-17 Impact factor: 17.440