Literature DB >> 21808837

Histomorphometric analysis of bone tissue repair in rabbits after insertion of titanium screws under different torque.

Fabrício Togni1, Fabíola Baras, Marina de Oliveira Ribas, Murched Omar Taha.   

Abstract

PURPOSE: To evaluate the inflammatory response of rabbit bone after insertion of titanium screws under different torque values.
METHODS: Four holes were made in the back tibia of fifteen New Zealand male albino rabbits; three screws were placed in each animal and a control hole remained without a screw. The screws were inserted with 0, 5 or 10 N.cm of torque. The animals were assigned to five groups according to the day of sacrifice after surgery (2, 7, 14, 21 or 42 days). The inflammatory cells and the thickness of the bone tissue around the screws was count.
RESULTS: The screws were associated with a larger number of inflammatory cells when compared to the control hole. There was no statistically significant difference when several comparisons were made among the groups with different torque intensity.
CONCLUSIONS: The histological changes were not statistically significant. There was a trend toward an increase in inflammatory cells found in local bone tissue surrounding the titanium screws installed with the highest torque. There was a tendency toward the formation of a lower thickness of tissue surrounding those bone screws that were inserted with higher torque.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21808837     DOI: 10.1590/s0102-86502011000400003

Source DB:  PubMed          Journal:  Acta Cir Bras        ISSN: 0102-8650            Impact factor:   1.388


  4 in total

1.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

2.  Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface.

Authors:  Patrícia Silva; Rodrigo César Rosa; Antonio Carlos Shimano; Helton L A Defino
Journal:  Eur Spine J       Date:  2013-05-08       Impact factor: 3.134

3.  Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons.

Authors:  James W A Fletcher; Verena Neumann; Lisa Wenzel; Boyko Gueorguiev; R Geoff Richards; Harinderjit S Gill; Michael R Whitehouse; Ezio Preatoni
Journal:  J Orthop Surg Res       Date:  2021-10-26       Impact factor: 2.359

4.  Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: pilot scan electron microscope and mechanical studies.

Authors:  André Walter; Heinz Winsauer; Jordi Marcé-Nogué; Sergi Mojal; Andreu Puigdollers
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-09-01
  4 in total