Literature DB >> 21801977

Comparative assessment of four blood pressure measurement methods in hypertensives.

Maxime Lamarre-Cliché1, Nathalie N G Cheong, Pierre Larochelle.   

Abstract

INTRODUCTION: Discordance between blood pressure (BP) measurement methods can occur and create ambiguity. New automated office BP monitors (AOBPs) are widely available, but their role is presently unclear. The objectives of this study are to quantify concordance among BP measurement methods and to define the diagnostic sensitivity, specificity, and predictive value of AOBPs in a population of hypertensive patients.
METHODS: The office mercury sphygmomanometer, the AOBP, an ambulatory BP monitor (ABPM), and home self-measurement with an automatic device were compared in a randomized, crossover study. BP averages and achievement of therapeutic goals were defined. Comparisons and agreement tests were performed. Diagnostic indices were calculated for the AOBP.
RESULTS: A total of 101 patients were enrolled. Average BP results were similar between measurement methods with the exception of daytime ABPM, which was significantly higher; figures are mean ± standard deviation (SD): sphygmomanometer, 129.9 ± 13.7/80.9 ± 9.3 mm Hg; AOBP, 128.4 ± 13.9/80.0 ± 9.4 mm Hg; 24-hour ABPM, 131.4 ± 11.7/78.7 ± 9.7 mm Hg; day ABPM, 135.5 ± 11.4/82.0 ± 11.9 mm Hg; home self-measurement, 131.0 ± 14.3/82.5 ± 8.2 mm Hg. Discordance in the achievement of therapeutic goals was observed in 58 patients, with only 26 cases being explained by masked hypertension or "white coat syndrome" according to all measurements. Disagreement was greater when office methods were compared with ambulatory methods.
CONCLUSIONS: This study shows that the 4 measurement strategies provide similar average BP estimates but generate many discordant results. The AOBP device can be very valuable as a replacement for the sphygmomanometer.
Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21801977     DOI: 10.1016/j.cjca.2011.05.001

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  11 in total

1.  Unattended Automated Office Blood Pressure Measurement and Cardiac Target Organ Damage, A Pilot Study.

Authors:  Claudia Palomba; Simone Donadio; Grazia Canciello; Maria Angela Losi; Raffaele Izzo; Maria Virginia Manzi; Federica De Pisapia; Costantino Mancusi; Nicola De Luca
Journal:  High Blood Press Cardiovasc Prev       Date:  2019-08-23

2.  White-Coat Effect Is Uncommon in Patients With Refractory Hypertension.

Authors:  Mohammed Siddiqui; Eric K Judd; Suzanne Oparil; David A Calhoun
Journal:  Hypertension       Date:  2017-07-10       Impact factor: 10.190

3.  MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

Authors:  Kimberly C Blom; Sasha Farina; Yessica-Haydee Gomez; Norm R C Campbell; Brenda R Hemmelgarn; Lyne Cloutier; Donald W McKay; Martin Dawes; Sheldon W Tobe; Peter Bolli; Mark Gelfer; Donna McLean; Gillian Bartlett; Lawrence Joseph; Robin Featherstone; Ernesto L Schiffrin; Stella S Daskalopoulou
Journal:  Curr Hypertens Rep       Date:  2015-04       Impact factor: 5.369

4.  Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement.

Authors:  Hemal Bhatt; Mohammed Siddiqui; Eric Judd; Suzanne Oparil; David Calhoun
Journal:  J Am Soc Hypertens       Date:  2016-03-30

Review 5.  The optimal use of automated office blood pressure measurement in clinical practice.

Authors:  Emmanuel A Andreadis; Charalampia V Geladari; Epameinondas T Angelopoulos
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-28       Impact factor: 3.738

6.  Eliminating the human factor in office blood pressure measurement.

Authors:  Martin G Myers
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-01-04       Impact factor: 3.738

7.  Low Blood Pressure Is Associated With Greater Risk for Cardiovascular Events in Treated Adults With and Without Apparent Treatment-Resistant Hypertension.

Authors:  Brent M Egan; Bo Kai; C Shaun Wagner; Douglas O Fleming; Joseph H Henderson; Archie H Chandler; Angelo Sinopoli
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-10-21       Impact factor: 3.738

8.  Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.

Authors:  Michael Roerecke; Janusz Kaczorowski; Martin G Myers
Journal:  JAMA Intern Med       Date:  2019-03-01       Impact factor: 44.409

Review 9.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

10.  Quality improvement project for managing elevated blood pressure in a primary care setting.

Authors:  Stephanie M Thomas; Holly B Cassells
Journal:  Integr Blood Press Control       Date:  2017-10-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.