Abtin Foroohar1, Rick Tosti, John M Richmond, John P Gaughan, Asif M Ilyas.
Abstract
SUMMARY: Proximal humerus fractures (PHF) are common injuries, but previous studies have documented poor inter-observer reliability in fracture classification. This disparity has been attributed to multiple variables including poor imaging studies and inadequate surgeon experience. The purpose of this study is to evaluate whether inter-observer agreement can be improved with the application of multiple imaging modalities including X-ray, CT, and 3D CT reconstructions, stratified by physician experience, for both classification and treatment of PHFs.Entities:
Mesh:
Year: 2011 PMID: 21801370 PMCID: PMC3162565 DOI: 10.1186/1749-799X-6-38
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Figure 4An example of a (A) 3D reconstruction showing AP, lateral, and PA views of a right shoulder. Most popular answers: 50% of raters classified this image as a 3-part fracture (37.5% classified 4-part) and 75% recommended ORIF. From the same patient are (B) coronal and axial views of the CT scan with (C) AP and lateral X-rays.
Overall inter-observer agreement
| Classification | Classification | Treatment | ||||
|---|---|---|---|---|---|---|
| Plain film X-ray | 0.1416 | (0.1177-0.1655) | slight | 0.2852 | (0.2600-0.3104) | fair |
| 2D CT scan | 0.0690 | (0.0000-0.0920) | slight | 0.3285 | (0.3028-0.3543) | fair |
| 3D reconstruction | 0.0947 | (0.0710-0.1185) | slight | 0.3082 | (0.2817-0.3346) | fair |
Inter-observer agreement subdivided by fracture type
| 2 Part Neer Fractures | ||||||
|---|---|---|---|---|---|---|
| Plain film X-ray | 0.0358 | (0.0000-0.0907) | slight | 0.1494 | (0.0959-0.2030) | slight |
| 2D CT scan | 0.0448 | (0.0000-0.0977) | slight | 0.2446 | (0.1912-0.2980) | fair |
| 3D reconstruction | 0.0770 | (0.0251-0.1290) | slight | 0.1793 | (0.1241-0.2344) | slight |
| Plain film X-ray | 0.0877 | (0.0556-0.1198) | slight | 0.3430 | (0.3057-0.3802) | fair |
| 2D CT scan | 0.0524 | (0.0000-0.0850) | slight | 0.2860 | (0.2492-0.3229) | fair |
| 3D reconstruction | 0.0960 | (0.0640-0.1284) | slight | 0.3579 | (0.3222-0.3935) | fair |
| Plain film X-ray | 0.2600 | (0.2105-0.3090) | fair | 0.1697 | (0.1481-0.2454) | slight |
| 2D CT scan | 0.4467 | (0.3989-0.4946) | moderate | 0.3368 | (0.2857-0.3880) | fair |
| 3D reconstruction | 0.5743 | (0.5225-0.6260) | moderate | 0.0893 | (0.0344-0.1441) | slight |
Inter-observer agreement subdivided by experience
| Upper Extremity Specialists | ||||||
|---|---|---|---|---|---|---|
| Plain film X-ray | 0.0315 | (0.0000-0.0917) | slight | 0.1605 | (0.0190-0.3020) | slight |
| 2D CT scan | 0.233 | (0.1096-0.3339) | fair | 0.4673 | (0.3294-0.6052) | moderate |
| 3D reconstruction | 0.3246 | (0.1946-0.4546) | fair | 0.1832 | (0.0333-0.3330) | slight |
| Plain film X-ray | 0.1079 | (0.0467-.01691) | slight | 0.3883 | (0.3213-0.4553) | fair |
| 2D CT scan | 0.0351 | (0.0000-0.0914) | slight | 0.46 | (0.3945-0.5255) | moderate |
| 3D reconstruction | 0.036 | (0.0000-0.0980) | slight | 0.4069 | (0.3405-0.4734) | moderate |
| Plain film X-ray | 0.2184 | (0.0760-0.3608) | fair | 0.4273 | (0.2849-0.5697) | moderate |
| 2D CT scan | 0.0597 | (0.0000-0.2230) | slight | 0.2613 | (0.1133-0.4094) | fair |
| 3D reconstruction | 0.0364 | (0.0000-0.1670) | slight | 0.368 | (0.2154-0.5210) | fair |
| Plain film X-ray | 0.0295 | (0.0000-0.1807) | slight | 0.029 | (0.0000-0.1701) | slight |
| 2D CT scan | 0.1111 | (0.0388-0.2610) | slight | 0.1288 | (0.0397-0.2973) | slight |
| 3D reconstruction | 0.1438 | (0.0390-0.2915) | slight | 0.2284 | (0.0738-0.3831) | fair |