Literature DB >> 17567348

Evaluation of four airway training manikins as patient simulators for the insertion of single use laryngeal mask airways.

T M Cook1, C Green, J McGrath, R Srivastava.   

Abstract

We evaluated the performance of four manikins: Airsim(trade mark), Bill 1, Airway Management Trainer and Airway Trainer, as simulators for insertion of single-use laryngeal mask airways and the reusable LMA Classic. Sixteen volunteer anaesthetists inserted each laryngeal mask airway into each manikin twice. Insertions were scored for ease of insertion, clinical and fibreoptic position, and lung ventilation (maximum score 10). Scores < 7 were classified 'poor' and < 5 'failure'. We analysed manikin and laryngeal mask airway performance. Poor insertion rate was 15% (range 9-21%) and was lowest for the VBM manikin (p = 0.02). Insertion failure rate was 2.6% and did not differ significantly between manikins (p = 0.2). Overall manikin performance was significantly different (p < 0.0001). The VBM manikin scored best, with all other manikins equivalent. The VBM manikin performed significantly better for three individual laryngeal mask airways. Overall performance differences of laryngeal mask airways were statistically significant (p < 0.001) but individual comparisons were not. Silicone devices performed better than PVC devices (p < 0.05) Devices with and without grilles performed similarly. All manikins were adequate. The VBM manikin performed best overall and for several individual laryngeal mask airways. The methodology is useful for future evaluations of devices, both manikins and supraglottic airways. Further human clinical research is required.

Entities:  

Mesh:

Year:  2007        PMID: 17567348     DOI: 10.1111/j.1365-2044.2007.05068.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Fiberoptic-guided tracheal tube placement through the air-Q® Intubating Laryngeal Airway: a performance study in a manikin.

Authors:  Richard E Galgon; Kristopher M Schroeder; Christopher S Schmidt; Adrian A Matioc; Seungbong Han; Adin-Cristian Andrei; Aaron M Joffe
Journal:  J Anesth       Date:  2011-07-29       Impact factor: 2.078

2.  Comparison between the Trachway video intubating stylet and Macintosh laryngoscope in four simulated difficult tracheal intubations: A manikin study.

Authors:  Jimmy Ong; Chia-Ling Lee; Shen-Jer Huang; Ming-Hwang Shyr
Journal:  Ci Ji Yi Xue Za Zhi       Date:  2016-07-27

3.  Comparison of the i-gel and other supraglottic airways in adult manikin studies: Systematic review and meta-analysis.

Authors:  Jiwon An; Sang Beom Nam; Jong Seok Lee; Jinae Lee; Hanna Yoo; Hye Mi Lee; Min-Soo Kim
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

4.  Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices.

Authors:  Axel Schmutz; Erich Bohn; Johannes Spaeth; Sebastian Heinrich
Journal:  Ther Clin Risk Manag       Date:  2019-03-01       Impact factor: 2.423

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.