Position of the prosthesis components in total ankle replacement and the effect on motion at the replaced joint.

Francesco Cenni1, Alberto Leardini, Andrea Cheli, Fabio Catani, Claudio Belvedere, Matteo Romagnoli, Sandro Giannini.   

Abstract

PURPOSE: In some cases of total ankle replacement, perfect alignment of the prosthetic components is not achieved. This study analyses the extent to which component positioning is critical for the final range of motion.
METHODS: Fourteen patients undergoing total ankle replacement were assessed preoperatively and postoperatively at seven and 13 months follow-up. X-ray pictures of the ankle were taken in static double leg stance, i.e. at neutral joint position, and in maximum plantarflexion and dorsiflexion. Measurements were obtained by a specially devised computer program based on anatomical reference points digitised on the radiograms. These allowed calculation of the position and orientation of the components in the sagittal and coronal planes, together with the joint range of motion.
RESULTS: The mean range of motion was about 34 degrees at the first follow-up and maintained at the second. Tibial and talar components were more anterior than the mid-tibial shaft in 11 and nine patients, respectively. Mean inclination was about four degrees posterior for the tibial component and nearly one degree anterior for the talar component. A significantly larger range of motion was found in ankles both with the talar component located and inclined more anteriorly than the tibial.
CONCLUSIONS: Correlation, though weak, was found between motion at the replaced ankle and possible residual subluxation and inclination of the components. However, a satisfactory range of motion was also achieved in those patients where recommended locations for the components could not be reached because of the size of the original joint deformity.

Entities:  

Mesh:

Year:  2011        PMID: 21789498      PMCID: PMC3291768          DOI: 10.1007/s00264-011-1323-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  34 in total

1.  Challenges in total ankle arthroplasty.

Authors:  Lowell H Gill
Journal:  Foot Ankle Int       Date:  2004-04       Impact factor: 2.827

2.  A new semi-automated measurement technique based on X-ray pictures for ankle morphometry.

Authors:  Rita Stagni; Alberto Leardini; Fabio Catani; Angelo Cappello
Journal:  J Biomech       Date:  2004-07       Impact factor: 2.712

3.  Accurate measurement of ankle range of motion after total ankle arthroplasty.

Authors:  J Chris Coetzee; Michael D Castro
Journal:  Clin Orthop Relat Res       Date:  2004-07       Impact factor: 4.176

4.  Misalignment of total ankle components can induce high joint contact pressures.

Authors:  N Espinosa; M Walti; P Favre; J G Snedeker
Journal:  J Bone Joint Surg Am       Date:  2010-05       Impact factor: 5.284

5.  Clinical evaluation and radiographic assessment of bone lysis of the AES total ankle replacement.

Authors:  Jean-Luc Besse; Nuno Brito; Christophe Lienhart
Journal:  Foot Ankle Int       Date:  2009-10       Impact factor: 2.827

6.  Total ankle replacement compatible with ligament function produces mobility, good clinical scores, and low complication rates: an early clinical assessment.

Authors:  Sandro Giannini; Matteo Romagnoli; John J O'Connor; Francesco Malerba; Alberto Leardini
Journal:  Clin Orthop Relat Res       Date:  2010-06-18       Impact factor: 4.176

Review 7.  Complications of total ankle replacement.

Authors:  S F Conti; Y S Wong
Journal:  Clin Orthop Relat Res       Date:  2001-10       Impact factor: 4.176

8.  Mobility of the human ankle and the design of total ankle replacement.

Authors:  Alberto Leardini; John J O'Connor; Fabio Catani; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2004-07       Impact factor: 4.176

9.  Analysis of joint laxity after total ankle arthroplasty: cadaver study.

Authors:  Kota Watanabe; Xavier M Crevoisier; Harold B Kitaoka; Kristin D Zhao; Lawrence J Berglund; Kenton R Kaufman; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2009-07-24       Impact factor: 2.063

10.  Computer-assisted design of the sagittal shapes of a ligament-compatible total ankle replacement.

Authors:  A Leardini; F Catani; S Giannini; J J O'Connor
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

View more
  8 in total

Review 1.  A systematic review of outcome and failure rate of uncemented Scandinavian total ankle replacement.

Authors:  Hongmou Zhao; Yunfeng Yang; Guangrong Yu; Jiaqian Zhou
Journal:  Int Orthop       Date:  2011-09-01       Impact factor: 3.075

2.  Single-stage supramalleolar osteotomy for coronal plane deformity.

Authors:  Alexej Barg; Charles L Saltzman
Journal:  Curr Rev Musculoskelet Med       Date:  2014-12

Review 3.  Supramalleolar osteotomies for degenerative joint disease of the ankle joint: indication, technique and results.

Authors:  Alexej Barg; Geert I Pagenstert; Monika Horisberger; Jochen Paul; Marcel Gloyer; Heath B Henninger; Victor Valderrabano
Journal:  Int Orthop       Date:  2013-09       Impact factor: 3.075

4.  Total ankle arthroplasty versus ankle arthrodesis. Comparison of sports, recreational activities and functional outcome.

Authors:  Reinhard Schuh; Jochen Hofstaetter; Martin Krismer; Roberto Bevoni; Reinhard Windhager; Hans-Joerg Trnka
Journal:  Int Orthop       Date:  2011-12-16       Impact factor: 3.075

5.  Comparison of cartilage and bone morphological models of the ankle joint derived from different medical imaging technologies.

Authors:  Gilda Durastanti; Alberto Leardini; Sorin Siegler; Stefano Durante; Alberto Bazzocchi; Claudio Belvedere
Journal:  Quant Imaging Med Surg       Date:  2019-08

6.  Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement.

Authors:  Matthias Braito; Michael Liebensteiner; Dietmar Dammerer; Martin Krismer; Martin Pfurner; Rainer Biedermann
Journal:  J Orthop Surg Res       Date:  2015-05-20       Impact factor: 2.359

7.  Methodology for Measurement of in vivo Tibiotalar Kinematics After Total Ankle Replacement Using Dual Fluoroscopy.

Authors:  Dylan J Blair; Alexej Barg; K Bo Foreman; Andrew E Anderson; Amy L Lenz
Journal:  Front Bioeng Biotechnol       Date:  2020-05-05

Review 8.  Patient-specific instrumentation in total ankle arthroplasty.

Authors:  Antonio Mazzotti; Alberto Arceri; Simone Zielli; Simone Bonelli; Valentina Viglione; Cesare Faldini
Journal:  World J Orthop       Date:  2022-03-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.