Measurement of Defibrillator Surface Potentials for Simulation Verification.

Jess D Tate1, Jeroen G Stinstra, Thomas A Pilcher, Rob S Macleod.   

Abstract

Despite the growing use of implantable cardioverter defibrillators (ICDs) in adults and children, there has been little progress in optimizing device and electrode placement. To facilitate effective placement of ICDs, especially in pediatric cases, we have developed a predictive model that evaluates the efficacy of a delivered shock. Most recently, we have also developed an experimental validation approach based on measurements from clinical cases. The approach involves obtaining body surface potential maps of ICD discharges during implantation surgery and comparing these measured potentials with simulated surface potentials to determine simulation accuracy. Comparison of the simulated and measured potentials yielded very similar patterns and a typical correlation greater than 0.9, suggesting that the predictive simulation generates realistic potential values. Ongoing sensitivity studies will determine the robustness of the results and pave the way for use of this approach for assisting optimization of ICD use.

Entities:  

Year:  2010        PMID: 21779128      PMCID: PMC3138150     

Source DB:  PubMed          Journal:  Comput Cardiol (2010)        ISSN: 2325-887X


  6 in total

1.  High-energy defibrillation impairs myocyte contractility and intracellular calcium dynamics.

Authors:  Giuseppe Ristagno; Tong Wang; Wanchun Tang; Shijie Sun; Carlos Castillo; Max Harry Weil
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

2.  Nontransvenous implantable cardioverter defibrillator systems: not just for small pediatric patients.

Authors:  John D Kugler; Christopher C Erickson
Journal:  J Cardiovasc Electrophysiol       Date:  2006-01

3.  Heart disease and stroke statistics--2010 update: a report from the American Heart Association.

Authors:  Donald Lloyd-Jones; Robert J Adams; Todd M Brown; Mercedes Carnethon; Shifan Dai; Giovanni De Simone; T Bruce Ferguson; Earl Ford; Karen Furie; Cathleen Gillespie; Alan Go; Kurt Greenlund; Nancy Haase; Susan Hailpern; P Michael Ho; Virginia Howard; Brett Kissela; Steven Kittner; Daniel Lackland; Lynda Lisabeth; Ariane Marelli; Mary M McDermott; James Meigs; Dariush Mozaffarian; Michael Mussolino; Graham Nichol; Véronique L Roger; Wayne Rosamond; Ralph Sacco; Paul Sorlie; Véronique L Roger; Randall Stafford; Thomas Thom; Sylvia Wasserthiel-Smoller; Nathan D Wong; Judith Wylie-Rosett
Journal:  Circulation       Date:  2009-12-17       Impact factor: 29.690

4.  Limited lead selection for estimation of body surface potential maps in electrocardiography.

Authors:  R L Lux; C R Smith; R F Wyatt; J A Abildskov
Journal:  IEEE Trans Biomed Eng       Date:  1978-05       Impact factor: 4.538

5.  Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart.

Authors:  Bryan C Cannon; Richard A Friedman; Arnold L Fenrich; Charles D Fraser; E Dean McKenzie; Naomi J Kertesz
Journal:  Pacing Clin Electrophysiol       Date:  2006-02       Impact factor: 1.976

6.  A computer modeling tool for comparing novel ICD electrode orientations in children and adults.

Authors:  Matthew Jolley; Jeroen Stinstra; Steve Pieper; Rob Macleod; Dana H Brooks; Frank Cecchin; John K Triedman
Journal:  Heart Rhythm       Date:  2008-01-17       Impact factor: 6.343

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.