High-energy defibrillation impairs myocyte contractility and intracellular calcium dynamics.

Giuseppe Ristagno1, Tong Wang, Wanchun Tang, Shijie Sun, Carlos Castillo, Max Harry Weil.   

Abstract

OBJECTIVES: We examined the effects of energy delivered with electrical defibrillation on myocyte contractility and intracellular Ca2+ dynamics. We hypothesized that increasing the defibrillation energy would produce correspondent reduction in myocyte contractility and intracellular Ca2+ dynamics.
DESIGN: Randomized prospective study.
SETTING: University-affiliated research laboratory.
SUBJECTS: Ventricular myocytes from male Sprague-Dawley rat hearts.
MATERIALS AND METHODS: Ventricular cardiomyocytes loaded with Fura-2/AM were placed in a chamber mounted on an inverted microscope and superfused with a buffer solution at 37 degrees C. The cells were field stimulated to contract and mechanical properties were assessed using a video-based edge-detection system. Intracellular Ca2+ dynamics were evaluated with a dual-excitation fluorescence photomultiplier system. Myocytes were then randomized to receive 1) a single 0.5-J biphasic shock; 2) a single 1-J biphasic shock; 3) a single 2-J biphasic shock; and 4) a control group without shock. After the shock, myocytes were paced for an additional 4 mins.
RESULTS: A single 0.5-J shock did not have effects on contractility and intracellular Ca2+ dynamics. Higher energy shocks, i.e., 1- or 2-J shocks, significantly impaired contractility and intracellular Ca2+ dynamics. The adverse effects were greater after a 2-J shock compared with a 1-J shock.
CONCLUSIONS: Higher defibrillation energy significantly impairs ventricular contractility at the myocyte level. Reductions in cardiomyocyte shortening and intracellular Ca2+ dynamics abnormalities were greater when higher energy shock was used.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 20449905     DOI: 10.1097/ccm.0b013e31818a84c5

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  7 in total

1.  Validating defibrillation simulation in a human-shaped phantom.

Authors:  Jess D Tate; Thomas A Pilcher; Kedar K Aras; Brett M Burton; Rob S MacLeod
Journal:  Heart Rhythm       Date:  2019-11-23       Impact factor: 6.343

2.  Measuring defibrillator surface potentials: The validation of a predictive defibrillation computer model.

Authors:  Jess Tate; Jeroen Stinstra; Thomas Pilcher; Ahrash Poursaid; Matthew A Jolley; Elizabeth Saarel; John Triedman; Rob S MacLeod
Journal:  Comput Biol Med       Date:  2018-08-29       Impact factor: 4.589

3.  Measurement of Defibrillator Surface Potentials for Simulation Verification.

Authors:  Jess D Tate; Jeroen G Stinstra; Thomas A Pilcher; Rob S Macleod
Journal:  Comput Cardiol (2010)       Date:  2010-09-26

4.  Sufficient myocardial protection of del Nido cardioplegia regardless of ventricular mass and myocardial ischemic time in adult cardiac surgical patients.

Authors:  Ji Seong Kim; Jin Hee Jeong; Sin Ju Moon; Hyuk Ahn; Ho Young Hwang
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

5.  Verification of a Defibrillation Simulation Using Internal Electric Fields in a Human Shaped Phantom.

Authors:  Jess Tate; Thomas Pilcher; Kedar Aras; Brett Burton; Rob MacLeod
Journal:  Comput Cardiol (2010)       Date:  2014-09-07

6.  Ventricular Fibrillation Waveform Changes during Controlled Coronary Perfusion Using Extracorporeal Circulation in a Swine Model.

Authors:  Raúl J Gazmuri; Christopher L Kaufman; Alvin Baetiong; Jeejabai Radhakrishnan
Journal:  PLoS One       Date:  2016-08-18       Impact factor: 3.240

7.  A framework of current based defibrillation improves defibrillation efficacy of biphasic truncated exponential waveform in rabbits.

Authors:  Weiming Li; Jingru Li; Liang Wei; Jianjie Wang; Li Peng; Juan Wang; Changlin Yin; Yongqin Li
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.