Literature DB >> 21778921

The modified Bose method for the endovascular treatment of intracranial atherosclerotic arterial stenoses using the Enterprise stent.

Zsolt Vajda1, Elisabeth Schmid, Thomas Güthe, Christoph Klötzsch, Alfred Lindner, Ludwig Niehaus, Wolfgang Sperber, Jan Peters, Guy Arnold, Hansjörg Bäzner, Hans Henkes.   

Abstract

BACKGROUND: Balloon dilatation and deployment of a self-expanding stent is a safe treatment for intracranial atherosclerotic stenoses. The significant recurrence rate might be related to the high radial force of the Wingspan stent.
OBJECTIVE: To evaluate the procedural safety and stenosis recurrence rate by the use of a stent with reduced radial force (Enterprise).
METHODS: Two hundred nine atherosclerotic stenoses (189 patients) were treated (median age, 68 years; 132 male) in a single center. Lesion locations included internal carotid artery (n = 27), middle cerebral artery (n = 62), vertebral artery (n = 64), basilar artery (n = 55), and posterior cerebral artery (n = 1). Pre- and postmedication included acetylsalicylic acid and Clopidogrel for at least 12 months. Preprocedural and follow-up examinations included magnetic resonance imaging (MRI), neurological assessment, and digital subtraction angiography (6, 12, 26, and 52 weeks). Data registry included age, sex, normal vessel diameter, degree of stenosis, residual stenosis after stent, minimal in-stent diameter, and occurrence of ischemic symptoms during follow-up.
RESULTS: Median pre- and postprocedural stenosis rate was 65.4 ± 1% vs 25.1 ± 1%. Technical success rate was 100%. Major procedural complications occurred in 16 patients (8.1%). Combined neurological morbidity and mortality rate at 30 days was 2 patients (0.9%). In 174 stenoses (83%) angiographic follow-up was obtained (mean, 10.2 months). A restenosis (>50%) was observed in 43 (24.7%) cases after 4.2 months (mean) with 4 (9.3%) symptomatic lesions. Incidence of recurrent ischemia related to the stented artery was 2.2% during 10.2 months of mean follow-up.
CONCLUSION: Undersized balloon angioplasty and deployment of an Enterprise stent is safe and effective for intracranial stenoses. Follow-up results were equal to or better than those reported for bare-metal balloon-expandable or self-expanding stents and yielded excellent protection from recurrent ischemia.

Entities:  

Mesh:

Year:  2012        PMID: 21778921     DOI: 10.1227/NEU.0b013e31822dff0f

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  28 in total

1.  Comment on: Stenting versus aggressive medical therapy for intracranial arterial stenosis : Chimowitz MI, Lynn MJ, Derdeyn CP, et al. N Engl J Med. 2011;365:993-1003.

Authors:  H Henkes; H Bäzner; P K Nelson
Journal:  Clin Neuroradiol       Date:  2011-11       Impact factor: 3.649

2.  Neurovascular in-stent stenoses: treatment with conventional and drug-eluting balloons.

Authors:  Z Vajda; T Güthe; M Aguilar Perez; A Heuschmid; E Schmid; H Bäzner; H Henkes
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

3.  [Recent studies on intracranial stenosis].

Authors:  I Q Grunwald; S C Bertog
Journal:  Radiologe       Date:  2012-12       Impact factor: 0.635

4.  One-pass endovascular treatment of intracranial atherosclerotic stenosis with a novel PTA balloon and self-expanding microstent.

Authors:  Markus A Möhlenbruch; Johannes Pfaff; Christian Herweh; Julian Bösel; Timolaos Rizos; Simon Nagel; Peter A Ringleb; Martin Bendszus; Mirko Pham
Journal:  Neuroradiology       Date:  2016-06-16       Impact factor: 2.804

5.  Medium-term results of undersized angioplasty and stenting for symptomatic high-grade intracranial atherosclerotic stenosis with Enterprise.

Authors:  Aysun Erbahceci Salik; Hatem H Selcuk; Hasanagha Zalov; Fatih Kilinc; Musa Cirak; Batuhan Kara
Journal:  Interv Neuroradiol       Date:  2019-04-16       Impact factor: 1.610

6.  First Experiences with the New Enterprise2® Stent.

Authors:  C Herweh; S Nagel; J Pfaff; C Ulfert; M Wolf; M Bendszus; M Möhlenbruch
Journal:  Clin Neuroradiol       Date:  2016-09-27       Impact factor: 3.649

7.  Undersized angioplasty and stenting of symptomatic intracranial tight stenosis with Enterprise: Evaluation of clinical and vascular outcome.

Authors:  Kun-Yu Lee; David Yen-Ting Chen; Hui-Ling Hsu; Chi-Jen Chen; Ying-Chi Tseng
Journal:  Interv Neuroradiol       Date:  2015-11-04       Impact factor: 1.610

8.  [Application of Neuroform EZ stent in the treatment of severe intracranial arterial stenosis with complex symptomatic].

Authors:  Z C Jia; H J Bian; X Li; J Y Luan; C M Wang; Q J Liu; J T Han
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-10-18

9.  A novel technique for stenting of intracranial stenosis using the Neuroform Atlas stent and Gateway balloon catheter.

Authors:  Ariel Takayanagi; Pamela K Cheng; Lei Feng
Journal:  Interv Neuroradiol       Date:  2021-04-07       Impact factor: 1.610

10.  Factors affecting in-stent restenosis after angioplasty with the Enterprise stent for intracranial atherosclerotic diseases.

Authors:  Kun Zhang; Tian-Xiao Li; Zi-Liang Wang; Bu-Lang Gao; Jian-Jun Gu; Hui-Li Gao; Yong-Feng Wang; Jin-Chao Xia
Journal:  Sci Rep       Date:  2021-05-18       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.