A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images.

E Dall'Ara1, P Varga, D Pahr, P Zysset.   

Abstract

PURPOSE: The accuracy of QCT-based homogenized finite element (FE) models is strongly related to the accuracy of the prediction of bone volume fraction (BV/TV) from bone mineral density (BMD). The goal of this study was to establish a calibration methodology to relate the BMD computed with QCT with the BV/TV computed with micro-CT (microCT) over a wide range of bone mineral densities and to investigate the effect of region size in which BMD and BV/TV are computed.
METHODS: Six human vertebral bodies were dissected from the spine of six donors and scanned submerged in water with QCT (voxel size: 0.391 x 0.391 x 0.450 mm3) and microCT (isotropic voxel size: 0.018(3) mm3). The microCT images were segmented with a single level threshold. Afterward, QCT-grayscale, microCT-grayscale, and microCT-segmented images were registered. Two isotropic grids of 1.230 mm (small) and 4.920 mm (large) were superimposed on every image, and QCT(BMD) was compared both with microCT(BMD) and microCT(BV/TV) for each grid cell.
RESULTS: The ranges of QCT(BMD) for large and small regions were 9-559 mg/cm3 and -90 to 1006 mg/cm3, respectively. QCT(BMD) was found to overestimate microCT(BMD). No significant differences were found between the QCT(BMD)-microCT(BV/TV) regression parameters of the two grid sizes. However, the R2 was higher, and the standard error of the estimate (SEE) was lower for large regions when compared to small regions. For the pooled data, an extrapolated QCTBMD value equal to 1062 mg/ cm3 was found to correspond to 100% microCT(BV/TV).
CONCLUSIONS: A calibration method was defined to evaluate BV/TV from QCTBMD values for cortical and trabecular bone in vitro. The QCT(BMD-microCT(BV/TV) calibration was found to be dependent on the scanned vertebral section but not on the size of the regions. However, the higher SEE computed for small regions suggests that the deleterious effect of QCT image noise on FE modelling increases with decreasing voxel size.

Entities:  

Mesh:

Year:  2011        PMID: 21776797     DOI: 10.1118/1.3582946

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Locally measured microstructural parameters are better associated with vertebral strength than whole bone density.

Authors:  J Hazrati Marangalou; F Eckstein; V Kuhn; K Ito; M Cataldi; F Taddei; B van Rietbergen
Journal:  Osteoporos Int       Date:  2013-12-04       Impact factor: 4.507

Review 2.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

3.  The role of patient-mode high-resolution peripheral quantitative computed tomography indices in the prediction of failure strength of the elderly women's thoracic vertebral body.

Authors:  Y Lu; M Krause; N Bishop; K Sellenschloh; C-C Glüer; K Püschel; M Amling; M M Morlock; G Huber
Journal:  Osteoporos Int       Date:  2014-08-19       Impact factor: 4.507

4.  Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density.

Authors:  Luke Arentsen; Karen E Hansen; Masashi Yagi; Yutaka Takahashi; Ryan Shanley; Angela McArthur; Patrick Bolan; Taiki Magome; Douglas Yee; Jerry Froelich; Susanta K Hui
Journal:  J Bone Miner Metab       Date:  2016-12-09       Impact factor: 2.626

5.  Large cortical bone pores in the tibia are associated with proximal femur strength.

Authors:  Gianluca Iori; Johannes Schneider; Andreas Reisinger; Frans Heyer; Laura Peralta; Caroline Wyers; Melanie Gräsel; Reinhard Barkmann; Claus C Glüer; J P van den Bergh; Dieter Pahr; Kay Raum
Journal:  PLoS One       Date:  2019-04-17       Impact factor: 3.240

6.  Romosozumab Enhances Vertebral Bone Structure in Women With Low Bone Density.

Authors:  Kenneth Es Poole; Graham M Treece; Rose A Pearson; Andrew H Gee; Michael A Bolognese; Jacques P Brown; Stefan Goemaere; Andreas Grauer; David A Hanley; Carlos Mautalen; Chris Recknor; Yu-Ching Yang; Maria Rojeski; Cesar Libanati; Tristan Whitmarsh
Journal:  J Bone Miner Res       Date:  2021-12-16       Impact factor: 6.390

Review 7.  Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature.

Authors:  Nikolas K Knowles; Jacob M Reeves; Louis M Ferreira
Journal:  J Exp Orthop       Date:  2016-12-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.