Literature DB >> 30460147

Additive noise models for photoacoustic spatial coherence theory.

Brooke Stephanian1, Michelle T Graham2, Huayu Hou2, Muyinatu A Lediju Bell1,2.   

Abstract

Directly displaying the spatial coherence of photoacoustic signals (i.e., coherence-based photoacoustic imaging) remarkably improves image contrast, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and imaging depth when compared to conventional amplitude-based reconstruction techniques (e.g., backprojection, delay-and-sum beamforming, and Fourier-based reconstruction). We recently developed photoacoustic-specific theory to describe the spatial coherence process as a function of the element spacing on a receive acoustic aperture to enable photoacoustic image optimization without requiring experiments. However, this theory lacked noise models, which contributed to significant departures in coherence measurements when compared to experimental data, particularly at higher values of element separation. In this paper, we develop and implement two models based on experimental observations of noise in photoacoustic spatial coherence measurements to improve our existing spatial coherence theory. These models were derived to describe the effects of incident fluence variations, low-energy light sources (e.g., pulsed laser diodes and light-emitting diodes), averaging multiple signals from low-energy light sources, and imaging with light sources that are > 5mm from photoacoustic targets. Results qualitatively match experimental coherence functions and provide similar contrast, SNR, and CNR to experimental SLSC images. In particular, the added noise affects image quality metrics by introducing large variations in target contrast and significantly reducing target CNR and SNR when compared to minimal-noise cases. These results provide insight into additional requirements for optimization of coherence-based photoacoustic image quality.

Year:  2018        PMID: 30460147      PMCID: PMC6238926          DOI: 10.1364/BOE.9.005566

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  17 in total

1.  Optoacoustic imaging with synthetic aperture focusing and coherence weighting.

Authors:  C K Liao; M L Li; P C Li
Journal:  Opt Lett       Date:  2004-11-01       Impact factor: 3.776

2.  Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging.

Authors:  Thomas J Allen; Paul C Beard
Journal:  Opt Lett       Date:  2006-12-01       Impact factor: 3.776

3.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.

Authors:  Muyinatu A Lediju Bell; Nathanael Kuo; Danny Y Song; Emad M Boctor
Journal:  Biomed Opt Express       Date:  2013-09-04       Impact factor: 3.732

4.  Adaptive beamforming for photoacoustic imaging.

Authors:  Suhyun Park; Andrei B Karpiouk; Salavat R Aglyamov; Stanislav Y Emelianov
Journal:  Opt Lett       Date:  2008-06-15       Impact factor: 3.776

5.  In vivo visualization of prostate brachytherapy seeds with photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Nathanael P Kuo; Danny Y Song; Jin U Kang; Emad M Boctor
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

6.  Equivalence of time and aperture domain additive noise in ultrasound coherence.

Authors:  Nick B Bottenus; Gregg E Trahey
Journal:  J Acoust Soc Am       Date:  2015-01       Impact factor: 1.840

7.  SNR-dependent coherence-based adaptive imaging for high-frame-rate ultrasonic and photoacoustic imaging.

Authors:  Yu-Hsin Wang; Pai-Chi Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-08       Impact factor: 2.725

8.  Transurethral light delivery for prostate photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Xiaoyu Guo; Danny Y Song; Emad M Boctor
Journal:  J Biomed Opt       Date:  2015-03       Impact factor: 3.170

9.  Localization of Transcranial Targets for Photoacoustic-Guided Endonasal Surgeries.

Authors:  Muyinatu A Lediju Bell; Anastasia K Ostrowski; Ke Li; Peter Kazanzides; Emad M Boctor
Journal:  Photoacoustics       Date:  2015-06-09

10.  Handheld Real-Time LED-Based Photoacoustic and Ultrasound Imaging System for Accurate Visualization of Clinical Metal Needles and Superficial Vasculature to Guide Minimally Invasive Procedures.

Authors:  Wenfeng Xia; Mithun Kuniyil Ajith Singh; Efthymios Maneas; Naoto Sato; Yusuke Shigeta; Toshitaka Agano; Sebastian Ourselin; Simeon J West; Adrien E Desjardins
Journal:  Sensors (Basel)       Date:  2018-05-01       Impact factor: 3.576

View more
  4 in total

Review 1.  Photoacoustic-guided surgery from head to toe [Invited].

Authors:  Alycen Wiacek; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-03-16       Impact factor: 3.732

2.  Photoacoustic Spatial Coherence Theory and Applications to Coherence-Based Image Contrast and Resolution.

Authors:  Michelle T Graham; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-02       Impact factor: 2.725

3.  Generalized spatial coherence reconstruction for photoacoustic computed tomography.

Authors:  Jorge Tordera Mora; Xiaohua Feng; Nikhila Nyayapathi; Jun Xia; Liang Gao
Journal:  J Biomed Opt       Date:  2021-04       Impact factor: 3.758

4.  Photoacoustic image improvement based on a combination of sparse coding and filtering.

Authors:  Ebrahim Najafzadeh; Parastoo Farnia; Saeedeh N Lavasani; Maryam Basij; Yan Yan; Hossein Ghadiri; Alireza Ahmadian; Mohammad Mehrmohammadi
Journal:  J Biomed Opt       Date:  2020-10       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.