Literature DB >> 21752384

Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column.

Chunyan Hao1, David Morse, Franca Morra, Xiaoming Zhao, Paul Yang, Brian Nunn.   

Abstract

Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS-MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12 min with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in the method for each target compound to achieve true positive identification, and ¹³C, ¹⁵N-glyphosate is used as an internal standard to carry out isotope dilution mass spectrometric (IDMS) measurement for glyphosate. The instrument detection limits (IDLs) for glyphosate, AMPA and glufosinate are 1, 2 and 0.9 μg/L, respectively. Linearity of the detector response with a minimum coefficient of determination (R² value (R² > 0.995) was demonstrated in the range of ∼10 to 10³ μg/L for each analytes. Spiked drinking water, surface water and groundwater samples were analyzed using this method and the average recoveries of analytes in three matrices ranged from 77.0 to 102%, 62.1 to 101%, 66.1 to 93.7% while relative standard deviation ranged from 6.3 to 10.2%, 2.7 to 14.8%, 2.9 to 10.7%, respectively. Factors that may affect method performance, such as metal ions, sample preservation, and storage time, are also discussed. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21752384     DOI: 10.1016/j.chroma.2011.06.070

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  9 in total

1.  Mechanical behavior of fully expanded commercially available endovascular coronary stents.

Authors:  Josip Tambaca; Suncica Canic; Mate Kosor; R David Fish; David Paniagua
Journal:  Tex Heart Inst J       Date:  2011

2.  Preliminary recovery study of a commercial molecularly imprinted polymer for the extraction of glyphosate and AMPA in different environmental waters using MS.

Authors:  Bérengère Claude; Catherine Berho; Sami Bayoudh; Laurence Amalric; Emeline Coisy; Reine Nehmé; Philippe Morin
Journal:  Environ Sci Pollut Res Int       Date:  2017-03-29       Impact factor: 4.223

3.  Development of a sensitive direct injection LC-MS/MS method for the detection of glyphosate and aminomethylphosphonic acid (AMPA) in hard waters.

Authors:  Jake C Ulrich; P Lee Ferguson
Journal:  Anal Bioanal Chem       Date:  2021-04-12       Impact factor: 4.142

Review 4.  The Current Status of Analytical Methods Applied to the Determination of Polar Pesticides in Food of Animal Origin: A Brief Review.

Authors:  Emanuela Verdini; Ivan Pecorelli
Journal:  Foods       Date:  2022-05-23

5.  A Method for the Analysis of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Human Urine Using Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Zhong-Min Li; Kurunthachalam Kannan
Journal:  Int J Environ Res Public Health       Date:  2022-04-19       Impact factor: 4.614

6.  Capillary electrophoresis-mass spectrometry for the direct analysis of glyphosate: method development and application to beer beverages and environmental studies.

Authors:  Benedikt Wimmer; Martin Pattky; Leyla Gulu Zada; Martin Meixner; Stefan B Haderlein; Hans-Peter Zimmermann; Carolin Huhn
Journal:  Anal Bioanal Chem       Date:  2020-06-10       Impact factor: 4.142

7.  Approaches to liquid chromatography tandem mass spectrometry assessment of glyphosate residues in wine.

Authors:  L Pérez-Mayán; G Castro; M Ramil; R Cela; I Rodríguez
Journal:  Anal Bioanal Chem       Date:  2021-11-25       Impact factor: 4.142

8.  Determination of Glyphosate and AMPA in Food Samples Using Membrane Extraction Technique for Analytes Preconcentration.

Authors:  Katarzyna Gębura; Piotr P Wieczorek; Anna Poliwoda
Journal:  Membranes (Basel)       Date:  2021-12-24

9.  Effective and rugged analysis of glyphosate, glufosinate, and metabolites in Tenebrio molitor larva (mealworms) using liquid chromatography tandem mass spectrometry.

Authors:  Leesun Kim; Sujn Baek; Kyungae Son; Hee-Dong Lee; Dal-Soon Choi; Chang Jo Kim; Hyun Ho Noh
Journal:  Sci Rep       Date:  2021-09-02       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.