Microfiltration platform for continuous blood plasma protein extraction from whole blood during cardiac surgery.

Kiana Aran1, Alex Fok, Lawrence A Sasso, Neal Kamdar, Yulong Guan, Qi Sun, Akif Ündar, Jeffrey D Zahn.   

Abstract

This report describes the design, fabrication, and testing of a cross-flow filtration microdevice, for the continuous extraction of blood plasma from a circulating whole blood sample in a clinically relevant environment to assist in continuous monitoring of a patient's inflammatory response during cardiac surgeries involving cardiopulmonary bypass (CPB) procedures (about 400,000 adult and 20,000 pediatric patients in the United States per year). The microfiltration system consists of a two-compartment mass exchanger with two aligned sets of PDMS microchannels, separated by a porous polycarbonate (PCTE) membrane. Using this microdevice, blood plasma has been continuously separated from blood cells in a real-time manner with no evidence of bio-fouling or cell lysis. The technology is designed to continuously extract plasma containing diagnostic plasma proteins such as complements and cytokines using a significantly smaller blood volume as compared to traditional blood collection techniques. The microfiltration device has been tested using a simulated CPB circulation loop primed with donor human blood, in a manner identical to a clinical surgical setup, to collect plasma fractions in order to study the effects of CPB system components and circulation on immune activation during extracorporeal circulatory support. The microdevice, with 200 nm membrane pore size, was connected to a simulated CPB circuit, and was able to continuously extract ~15% pure plasma volume (100% cell-free) with high sampling frequencies which could be analyzed directly following collection with no need to further centrifuge or modify the fraction. Less than 2.5 ml total plasma volume was collected over a 4 h sampling period (less than one Vacutainer blood collection tube volume). The results tracked cytokine concentrations collected from both the reservoir and filtrate samples which were comparable to those from direct blood draws, indicating very high protein recovery of the microdevice. Additionally, the cytokine concentration increased significantly compared to baseline values over the circulation time for all cytokines analyzed. The high plasma protein recovery (over 80%), no indication of hemolysis and low level of biofouling on the membrane surface during the experimental period (over 4 h) were all indications of effective and reliable device performance for future clinical applications. The simple and robust design and operation of these devices allow operation over a wide range of experimental flow conditions and blood hematocrit levels to allow surgeons and clinicians autonomous usage in a clinical environment to better understand the mechanisms of injury resulting from cardiac surgery, and allow early interventions in patients with excessive postoperative complications to improve surgical outcomes. Ultimately, monolithic integration of this microfiltration device with a continuous microimmunoassay would create an integrated microanalysis system for tracking inflammation biomarkers concentrations in patients for point-of-care diagnostics, reducing blood analysis times, costs and volume of blood samples required for repeated assays.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21750810      PMCID: PMC4538598          DOI: 10.1039/c1lc20080a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  23 in total

1.  Continuous particle separation through deterministic lateral displacement.

Authors:  Lotien Richard Huang; Edward C Cox; Robert H Austin; James C Sturm
Journal:  Science       Date:  2004-05-14       Impact factor: 47.728

Review 2.  Blood-on-a-chip.

Authors:  Mehmet Toner; Daniel Irimia
Journal:  Annu Rev Biomed Eng       Date:  2005       Impact factor: 9.590

3.  Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications.

Authors:  Timothy A Crowley; Vincent Pizziconi
Journal:  Lab Chip       Date:  2005-07-19       Impact factor: 6.799

4.  A microfluidic device for continuous, real time blood plasma separation.

Authors:  Sung Yang; Akif Undar; Jeffrey D Zahn
Journal:  Lab Chip       Date:  2006-04-19       Impact factor: 6.799

5.  Separation of plasma from whole human blood in a continuous cross-flow in a molded microfluidic device.

Authors:  Virginia VanDelinder; Alex Groisman
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

6.  Equilibrium separation and filtration of particles using differential inertial focusing.

Authors:  Dino Di Carlo; Jon F Edd; Daniel Irimia; Ronald G Tompkins; Mehmet Toner
Journal:  Anal Chem       Date:  2008-02-15       Impact factor: 6.986

Review 7.  The inflammatory response to cardiopulmonary bypass.

Authors:  B E Miller; J H Levy
Journal:  J Cardiothorac Vasc Anesth       Date:  1997-05       Impact factor: 2.628

8.  The effects of complement activation during cardiopulmonary bypass. Attenuation by hypothermia, heparin, and hemodilution.

Authors:  F D Moore; K G Warner; S Assousa; C R Valeri; S F Khuri
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

9.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

10.  Irreversible, direct bonding of nanoporous polymer membranes to PDMS or glass microdevices.

Authors:  Kiana Aran; Lawrence A Sasso; Neal Kamdar; Jeffrey D Zahn
Journal:  Lab Chip       Date:  2010-01-07       Impact factor: 6.799

View more
  17 in total

1.  Development and validation of a low cost blood filtration element separating plasma from undiluted whole blood.

Authors:  Alexandra Homsy; Peter D van der Wal; Werner Doll; Roland Schaller; Stefan Korsatko; Maria Ratzer; Martin Ellmerer; Thomas R Pieber; Andreas Nicol; Nico F de Rooij
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  Printed microfluidic filter for heparinized blood.

Authors:  Stanley E R Bilatto; Nouran Y Adly; Daniel S Correa; Bernhard Wolfrum; Andreas Offenhäusser; Alexey Yakushenko
Journal:  Biomicrofluidics       Date:  2017-05-02       Impact factor: 2.800

3.  Characterization of thermoplastic microfiltration chip for the separation of blood plasma from human blood.

Authors:  Pin-Chuan Chen; Chih-Chun Chen; Kung-Chia Young
Journal:  Biomicrofluidics       Date:  2016-10-04       Impact factor: 2.800

4.  Capillary flow of blood in a microchannel with differential wetting for blood plasma separation and on-chip glucose detection.

Authors:  M Sneha Maria; P E Rakesh; T S Chandra; A K Sen
Journal:  Biomicrofluidics       Date:  2016-09-22       Impact factor: 2.800

Review 5.  Micro total analysis systems: fundamental advances and applications in the laboratory, clinic, and field.

Authors:  Michelle L Kovarik; Douglas M Ornoff; Adam T Melvin; Nicholas C Dobes; Yuli Wang; Alexandra J Dickinson; Philip C Gach; Pavak K Shah; Nancy L Allbritton
Journal:  Anal Chem       Date:  2012-12-04       Impact factor: 6.986

6.  A capillary dielectrophoretic chip for real-time blood cell separation from a drop of whole blood.

Authors:  Shu-Hsien Liao; Ching-Yu Chang; Hsien-Chang Chang
Journal:  Biomicrofluidics       Date:  2013-04-18       Impact factor: 2.800

7.  High-throughput and clogging-free microfluidic filtration platform for on-chip cell separation from undiluted whole blood.

Authors:  Yinuo Cheng; Xiongying Ye; Zengshuai Ma; Shuai Xie; Wenhui Wang
Journal:  Biomicrofluidics       Date:  2016-02-12       Impact factor: 2.800

8.  Development of a high-throughput arrayed neural circuitry platform using human induced neurons for drug screening applications.

Authors:  Joseph A Fantuzzo; Denise A Robles; Vincent R Mirabella; Ronald P Hart; Zhiping P Pang; Jeffrey D Zahn
Journal:  Lab Chip       Date:  2020-03-17       Impact factor: 6.799

9.  Automated microfluidic processing platform for multiplexed magnetic bead immunoassays.

Authors:  Lawrence A Sasso; Ian H Johnston; Mingde Zheng; Rohit K Gupte; Akif Ündar; Jeffrey D Zahn
Journal:  Microfluid Nanofluidics       Date:  2012-10       Impact factor: 2.529

10.  Continuous monitoring of inflammation biomarkers during simulated cardiopulmonary bypass using a microfluidic immunoassay device - a pilot study.

Authors:  Lawrence A Sasso; Kiana Aran; Yulong Guan; Akif Ündar; Jeffrey D Zahn
Journal:  Artif Organs       Date:  2013-01       Impact factor: 3.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.