Literature DB >> 27703594

Capillary flow of blood in a microchannel with differential wetting for blood plasma separation and on-chip glucose detection.

M Sneha Maria, P E Rakesh1, T S Chandra2, A K Sen1.   

Abstract

We report capillary flow of blood in a microchannel with differential wetting for the separation of a plasma from sample blood and subsequent on-chip detection of glucose present in a plasma. A rectangular polydimethylsiloxane microchannel with hydrophilic walls (on three sides) achieved by using oxygen plasma exposure enables capillary flow of blood introduced at the device inlet through the microchannel. A hydrophobic region (on all four sides) in the microchannel impedes the flow of sample blood, and the accumulated blood cells at the region form a filter to facilitate the separation of a plasma. The modified wetting property of the walls and hence the device performance could be retained for a few weeks by covering the channels with deionised water. The effects of the channel cross-section, exposure time, waiting time, and location and length of the hydrophobic region on the volume of the collected plasma are studied. Using a channel cross-section of 1000 × 400 μm, an exposure time of 2 min, a waiting time of 10 min, and a hydrophobic region of width 1.0 cm located at 10 mm from the device inlet, 450 nl of plasma was obtained within 15 min. The performance of the device was found to be unaffected (provides 450 nl of plasma in 15 min) even after 15 days. The purification efficiency and plasma recovery of the device were measured and found to be comparable with that obtained using the conventional centrifugation process. Detection of glucose at different concentrations in whole blood of normal and diabetic patients was performed (using 5 μl of sample blood within 15 min) to demonstrate the compatibility of the device with integrated detection modules.

Entities:  

Year:  2016        PMID: 27703594      PMCID: PMC5035299          DOI: 10.1063/1.4962874

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  25 in total

1.  Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS).

Authors:  Ivan K Dimov; Lourdes Basabe-Desmonts; Jose L Garcia-Cordero; Benjamin M Ross; Younggeun Park; Antonio J Ricco; Luke P Lee
Journal:  Lab Chip       Date:  2010-12-08       Impact factor: 6.799

2.  Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications.

Authors:  Timothy A Crowley; Vincent Pizziconi
Journal:  Lab Chip       Date:  2005-07-19       Impact factor: 6.799

3.  Geometrical focusing of cells in a microfluidic device: an approach to separate blood plasma.

Authors:  Magalie Faivre; Manouk Abkarian; Kimberly Bickraj; Howard A Stone
Journal:  Biorheology       Date:  2006       Impact factor: 1.875

4.  Temperature dependence of blood surface tension.

Authors:  J Rosina; E Kvasnák; D Suta; H Kolárová; J Málek; L Krajci
Journal:  Physiol Res       Date:  2007-05-31       Impact factor: 1.881

Review 5.  Recent advances in microparticle continuous separation.

Authors:  M Kersaudy-Kerhoas; R Dhariwal; M P Y Desmulliez
Journal:  IET Nanobiotechnol       Date:  2008-03       Impact factor: 1.847

6.  Contributions of red cells and plasma to blood viscosity in preterm and full-term infants and adults.

Authors:  O Linderkamp; H T Versmold; K P Riegel; K Betke
Journal:  Pediatrics       Date:  1984-07       Impact factor: 7.124

Review 7.  Micro total analysis systems for cell biology and biochemical assays.

Authors:  Michelle L Kovarik; Philip C Gach; Douglas M Ornoff; Yuli Wang; Joseph Balowski; Lila Farrag; Nancy L Allbritton
Journal:  Anal Chem       Date:  2011-10-21       Impact factor: 6.986

8.  Acoustic whole blood plasmapheresis chip for prostate specific antigen microarray diagnostics.

Authors:  Andreas Lenshof; Asilah Ahmad-Tajudin; Kerstin Järås; Ann-Margret Swärd-Nilsson; Lena Aberg; György Marko-Varga; Johan Malm; Hans Lilja; Thomas Laurell
Journal:  Anal Chem       Date:  2009-08-01       Impact factor: 6.986

9.  The interaction of blood components with PDMS (polydimethylsiloxane) and LDPE (low-density polyethylene) in a baboon ex vivo arteriovenous shunt model.

Authors:  E M Keough; W C Mackey; R Connolly; T Foxall; K Ramberg-Laskaris; J L McCullough; T F O'Donnell; A D Callow
Journal:  J Biomed Mater Res       Date:  1985 May-Jun

10.  Hemolysis-free blood plasma separation.

Authors:  Jun Ho Son; Sang Hun Lee; Soongweon Hong; Seung-min Park; Joseph Lee; Andrea M Dickey; Luke P Lee
Journal:  Lab Chip       Date:  2014-05-14       Impact factor: 6.799

View more
  4 in total

1.  Synchronization and control of capillary flows in rectangular microchannel with spacers.

Authors:  Kui Song; Lina Zhang; Zheng Zhou; Ruijie Huang; Xu Zheng
Journal:  Biomicrofluidics       Date:  2020-07-15       Impact factor: 2.800

2.  Capillary flow-driven microfluidic device with wettability gradient and sedimentation effects for blood plasma separation.

Authors:  M Sneha Maria; P E Rakesh; T S Chandra; A K Sen
Journal:  Sci Rep       Date:  2017-03-03       Impact factor: 4.379

3.  Thermopneumatic suction integrated microfluidic blood analysis system.

Authors:  Chiao-Hsun Yang; Yu-Ling Hsieh; Ping-Hsien Tsou; Bor-Ran Li
Journal:  PLoS One       Date:  2019-03-07       Impact factor: 3.240

Review 4.  Potential Point-of-Care Microfluidic Devices to Diagnose Iron Deficiency Anemia.

Authors:  Boon Kar Yap; Siti Nur'Arifah M Soair; Noor Azrina Talik; Wai Feng Lim; Lai Mei I
Journal:  Sensors (Basel)       Date:  2018-08-10       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.