Literature DB >> 23305589

Continuous monitoring of inflammation biomarkers during simulated cardiopulmonary bypass using a microfluidic immunoassay device - a pilot study.

Lawrence A Sasso1, Kiana Aran, Yulong Guan, Akif Ündar, Jeffrey D Zahn.   

Abstract

This work demonstrates the use of a continuous online monitoring system for tracking systemic inflammation biomarkers during cardiopulmonary bypass (CPB) procedures. The ability to monitor inflammation biomarkers during CPB will allow surgical teams to actively treat inflammation and reduce harmful effects on postoperative morbidity and mortality, enabling improved patient outcomes. A microfluidic device has been designed which allows automation of the individual processing steps of a microbead immunoassay to allow continuous tracking of antigen concentrations. Preliminary experiments have demonstrated that the results produced by the microimmunoassay are comparable to results produced from a standard enzyme-linked immunosorbent assay (r = 0.98). Additionally, integration of the assay with a simulated CPB circuit has been demonstrated with temporal tracking of C3a concentrations within blood continuously sampled from the circuit. The presented work describes the motivation, design challenges, and preliminary experimental results of this project.
© 2013, Copyright the Authors. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23305589      PMCID: PMC3545401          DOI: 10.1111/aor.12021

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  34 in total

1.  Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection.

Authors:  Kiichi Sato; Maho Yamanaka; Tomokazu Hagino; Manabu Tokeshi; Hiroko Kimura; Takehiko Kitamori
Journal:  Lab Chip       Date:  2004-11-10       Impact factor: 6.799

2.  Inhibition of complement, neutrophil, and platelet activation by an anti-factor D monoclonal antibody in simulated cardiopulmonary bypass circuits.

Authors:  M Fung; P G Loubser; A Undar; M Mueller; C Sun; W N Sun; W K Vaughn; C D Fraser
Journal:  J Thorac Cardiovasc Surg       Date:  2001-07       Impact factor: 5.209

3.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

4.  The benefits of continuous ultrafiltration in pediatric cardiac surgery.

Authors:  Kenan Sever; Turkan Tansel; Murat Basaran; Eylul Kafali; Murat Ugurlucan; Omer Ali Sayin; Ufuk Alpagut; Enver Dayioglu; Ertan Onursal
Journal:  Scand Cardiovasc J       Date:  2004-10       Impact factor: 1.589

5.  Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples.

Authors:  A Bhattacharyya; C M Klapperich
Journal:  Biomed Microdevices       Date:  2007-04       Impact factor: 2.838

6.  Pulmonary inflammatory mediators after sevoflurane and thiopentone anaesthesia in pigs.

Authors:  R S K Takala; H R Soukka; M S Salo; O A Kirvelä; P O Kääpä; A A Rajamäki; A Riutta; R E Aantaa
Journal:  Acta Anaesthesiol Scand       Date:  2004-01       Impact factor: 2.105

7.  Elimination of proinflammatory cytokines in pediatric cardiac surgery: analysis of ultrafiltration method and filter type.

Authors:  Pascal A Berdat; Evelyne Eichenberger; Julia Ebell; Jean-Pierre Pfammatter; Mladen Pavlovic; Claudia Zobrist; Erich Gygax; Urs Nydegger; Thierry Carrel
Journal:  J Thorac Cardiovasc Surg       Date:  2004-06       Impact factor: 5.209

8.  Automated microfluidic processing platform for multiplexed magnetic bead immunoassays.

Authors:  Lawrence A Sasso; Ian H Johnston; Mingde Zheng; Rohit K Gupte; Akif Ündar; Jeffrey D Zahn
Journal:  Microfluid Nanofluidics       Date:  2012-10       Impact factor: 2.529

9.  Comparative effectiveness of methylprednisolone and zero-balance ultrafiltration on inflammatory response after pediatric cardiopulmonary bypass.

Authors:  Jinping Liu; Bingyang Ji; Cun Long; Chunhua Li; Zhengyi Feng
Journal:  Artif Organs       Date:  2007-07       Impact factor: 3.094

10.  Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol.

Authors:  Andrew C Barton; Frank Davis; Séamus P J Higson
Journal:  Anal Chem       Date:  2008-07-22       Impact factor: 6.986

View more
  4 in total

1.  Analytical methods of antibody surface coverage and orientation on bio-functionalized magnetic beads: application to immunocapture of TNF-α.

Authors:  Etienne Laborie; Victor Le-Minh; Thanh Duc Mai; Mehdi Ammar; Myriam Taverna; Claire Smadja
Journal:  Anal Bioanal Chem       Date:  2021-08-17       Impact factor: 4.142

Review 2.  Immunomagnetic nanoparticle-based assays for detection of biomarkers.

Authors:  Hoyoung Park; Mintai P Hwang; Kwan Hyi Lee
Journal:  Int J Nanomedicine       Date:  2013-11-22

3.  Smart Surgical Catheter for C-Reactive Protein Sensing Based on an Imperceptible Organic Transistor.

Authors:  Xudong Ji; Pengcheng Zhou; Ling Zhong; Aimin Xu; Anderson C O Tsang; Paddy K L Chan
Journal:  Adv Sci (Weinh)       Date:  2018-05-02       Impact factor: 16.806

4.  Fully integrated wearable impedance cytometry platform on flexible circuit board with online smartphone readout.

Authors:  Abbas Furniturewalla; Matthew Chan; Jianye Sui; Karan Ahuja; Mehdi Javanmard
Journal:  Microsyst Nanoeng       Date:  2018-07-30       Impact factor: 7.127

  4 in total