Literature DB >> 21749984

Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial.

Takashi Ishida1, Fumihiro Asano, Koichi Yamazaki, Naofumi Shinagawa, Satoshi Oizumi, Hiroshi Moriya, Mitsuru Munakata, Masaharu Nishimura.   

Abstract

BACKGROUND: Bronchoscopy using endobronchial ultrasound (EBUS) can help to diagnose small peripheral pulmonary lesions. However, although biopsy sites can be confirmed, a bronchoscope cannot be guided in EBUS. Virtual bronchoscopic navigation (VBN) can guide a bronchoscope with virtual images, but its value has not been confirmed.
METHODS: This prospective multicentre study examines the value of VBN-assisted EBUS for diagnosing small peripheral pulmonary lesions. 199 patients with small peripheral pulmonary lesions (diameter ≤30 mm) were randomly assigned to VBN-assisted (VBNA) or non-VBN-assisted (NVBNA) groups. A bronchoscope was introduced into the target bronchus of the VBNA group using the VBN system. Sites of specimen sampling were verified using EBUS with a guide sheath under fluoroscopy.
RESULTS: The diagnostic yield was higher for the VBNA than for the NVBNA group (80.4% vs 67.0%; p = 0.032). The duration of the examination and time elapsed until the start of sample collection were reduced in the VBNA compared with the NVBNA group (median (range), 24.0 (8.7-47.0) vs 26.2 (11.6-58.6) min, p = 0.016) and 8.1 (2.8-39.2) vs 9.8 (2.3-42.3) min, p = 0.045, respectively). The only adverse event was mild pneumothorax in a patient from the NVBNA group.
CONCLUSIONS: The diagnostic yield for small peripheral pulmonary lesions is increased when VBN is combined with EBUS. Clinical trial number UMIN000000569.

Entities:  

Mesh:

Year:  2011        PMID: 21749984      PMCID: PMC3221323          DOI: 10.1136/thx.2010.145490

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


Can virtual bronchoscopic navigation improve the bronchoscopic diagnostic yield for small peripheral pulmonary lesions? Bronchoscopy using endobronchial ultrasound (EBUS) can help to diagnose peripheral pulmonary lesions; however, EBUS cannot navigate the bronchoscope itself, so small lesions cannot always be reached. This multicentre, randomised study shows that the diagnostic yield for small peripheral pulmonary lesions is increased when virtual bronchoscopic navigation is combined with EBUS.

Introduction

Lung cancer is the leading cause of cancer death in Europe, the USA and Japan.1–3 Although imaging modalities including CT, MRI and positron emission tomography have been applied, pathological findings remain the benchmark for a diagnosis of lung cancer. The increased frequency of high quality CT application has allowed the identification of much smaller and far more pulmonary lesions than before.4 Suspected malignant pulmonary lesions can be diagnosed by bronchoscopy, but the sensitivity of detecting small peripheral lung cancer varies from 36% to 86% depending on the size of the lesion.5–7 According to the lung cancer diagnosis and treatment guidelines issued by the American College of Chest Physicians (ACCP),8 the diagnostic sensitivity of bronchoscopy for peripheral pulmonary lesions is 78%, whereas that for lesions <2 cm is 34%. In comparison, the reported diagnostic sensitivity of transthoracic needle aspiration (TTNA) is 90%, and TTNA is recommended for diagnosing lesions <2 cm. Consequently, TTNA is frequently applied in many countries, but the incidence of complications is fairly high. The British Thoracic Society (BTS) guidelines state that the incidence of pneumothorax is 0–61%, with chest tube drainage required in 3.3–15%, intrapulmonary haemorrhage in 5–16.9% and haemoptysis in 1.25–5%.9 The ACCP guidelines state with respect to bronchoscopy that, ‘…in expert hands, a radial probe US device can increase the diagnostic yield of FB while dealing with peripheral lesions of <20 mm in size. Its use can be considered prior to referring the patient for TTNA.’ The given grade of recommendation is 2B.8 Target lesions can be directly visualised by EBUS before attempting biopsies that raise the diagnostic yields for peripheral lesions10; reported diagnostic yields are 58.3–80%.10–13 However, EBUS cannot navigate the bronchoscope itself, so lesions cannot be reached in 8–20.8% of cases.11 13 Navigational bronchoscopy has recently improved the diagnostic approach to peripheral small lesions. Electromagnetic navigation (EMN) is one of two methods that are currently in clinical use, and one EMN system (inReach System; superDimension, Minneapolis, Minnesota, USA) has been marketed mainly in Europe and in the USA.14 Bronchoscopists navigate EMN systems using a positional sensor that determines direction based on an electromagnetic field generated around the patient's chest. Reported diagnostic yields of EMN for variously sized peripheral pulmonary lesions range from 69% to 74%.15–17 A randomised study has shown that EMN-assisted bronchoscopy combined with EBUS is more sensitive than either modality alone (diagnostic yield, 88% vs 69% and 59%, respectively).18 Virtual bronchoscopic navigation (VBN) is another method in which virtual bronchoscopic images of the bronchial path to a peripheral lesion are generated and used as a guide to navigate the bronchoscope.19 Since virtual bronchoscopic (VB) and bronchoscopic images are similar, the bronchoscope can be advanced near a target lesion according to the bronchial pathway displayed on the VB images. A VBN system has been developed that allows the automatic production of virtual images of the bronchial path that are matched with actual images for reliable bronchoscopic navigation to sampling sites.20 21 However, the value of VBN has not yet been clearly and statistically demonstrated. The present multicentre, prospective, randomised study examines the value of VBN-assisted EBUS for diagnosing small peripheral pulmonary lesions of suspected lung cancer.

Methods

Participants

We enrolled 199 patients who were referred to three Japanese medical centres between April 2006 and August 2007 with peripheral pulmonary lesions (mean diameter ≤3 cm calculated from axial CT images) suspected to be cancer that were not pathologically confirmed. Peripheral pulmonary lesions were defined as those that are surrounded by normal lung parenchyma and thus unlikely to be visualised by bronchoscopy. Most of these lesions were discovered by plain chest x-rays and/or CT images acquired for reasons other than the symptoms caused by the lesions. Eligible patients were men and women ≥20 years old who could tolerate bronchoscopy. The exclusion criteria comprised evidence of endobronchial disease revealed by chest CT, percutaneous oxygen saturation <90%, a range of known severe co-morbid conditions (unstable angina, acute myocardial infarction within the past 3 months, severe asthma or uncontrolled pulmonary infection), pregnancy and unable to proceed without anticoagulant or antiplatelet medications. We monitored the course of lesions that were <10 mm with ground-glass opacity confirmed by CT and excluded them from the study.

Randomisation and intervention

Eligible patients were randomly assigned to VBN-assisted (VBNA) or non-VBN-assisted (NVBNA) groups. Because others have shown that bronchoscopic diagnostic yield is associated with lesion size8 and physician skill, randomisation was based on lesion size (mean diameter <2 cm or 2–3 cm) and bronchoscopists used a randomised block design to ensure that these factors were balanced in the study arms. Independent, blinded, trial staff randomly assigned the patients before bronchoscopy. Scan data from multidetector chest CT (16- or 64-row; slice width, 0.5–2 mm) were acquired from all patients without using contrast medium before bronchoscopy. Individual CT data sets from the VBNA group were transferred to a workstation on which VBN software automatically created virtual bronchoscopic images21 within 20 min. The consecutive images could be moved forwards and backwards and rotated like a bronchoscope in a monitor positioned beside the video-bronchoscopic screen in the endoscopy suite. As assistant physician controlled the virtual bronchoscopic images20 during bronchoscopy and a bronchoscopist inserted an endoscope as instructed (figure 1). All patients were locally anaesthetised with lidocaine and examined using a thin video-bronchoscope (type P260F; outer diameter, 4.0 mm; Olympus Medical Systems, Tokyo, Japan). Additional pentazocine hydrochloride or hydroxyzine chloride was administered as required.
Figure 1

Virtual bronchoscopic navigation. An assistant physician controls virtual bronchoscopic images of the path leading to a peripheral lesion and a bronchoscopist inserts an endoscope as instructed.

Virtual bronchoscopic navigation. An assistant physician controls virtual bronchoscopic images of the path leading to a peripheral lesion and a bronchoscopist inserts an endoscope as instructed. Bronchoscopic insertion was assisted using the VBN system in the VBNA group. The bronchoscope was introduced into the bronchus of the NVBNA group without VBN support and with reference only to CT axial images. Lesions were visualised in both groups by inserting a 20 MHz mechanical radial-type EBUS probe (external diameter, 1.4 mm; UM-S20-17S; Olympus Medical Systems) with a guide sheath (K-201; Olympus Medical Systems) through an endoscopic channel. This probe was withdrawn as soon as the lesion was visualised. Pathological samples were collected using forceps and/or a brush introduced into the guide sheath.12 If the lesion was not visualised by EBUS, the approach to sampling was decided by the bronchoscopist. The area around the bronchial target was washed as determined by the bronchoscopist with 20 ml of saline as a supplementary procedure. Biopsy samples were immediately fixed in formalin, brush smears on glass slides were immediately fixed in alcohol, and pathologists who were blinded to the results of randomisation processed and evaluated all specimens using standard procedures. The presence of bacteria was assessed in some portions of brush smears and/or lavage. All patients were positioned on an x-ray table, correct device placement was confirmed and sampling was conducted under fluoroscopy.

Outcomes

The primary end point was bronchoscopic diagnostic yield defined as all instances in which the results matched the final diagnosis confirmed by pathological and/or bacterial assessment of bronchoscopic samples. The key secondary end point was total examination duration, which was calculated as the interval between the moment the endoscope passed the vocal cords until its withdrawal from the trachea. Other secondary end points were the interval until the start of sample collection, duration of x-ray fluoroscopy and the generation number of the inserted bronchi. A segmental bronchus was defined as third generation. Safety end points of interest included severe haemorrhage, pneumothorax, hypoxaemia, lidocaine intoxication, arrhythmia, pneumonia and other serious adverse events. Retrieved blood loss >50 ml mixed with or without saline lavage was defined as significant. The safety of all patients was assessed.

Study follow-up

If a lesion was undiagnosed by bronchoscopy, we recommended that the patient consider undergoing other diagnostic procedures, including CT-guided fine needle aspiration (FNA) or surgical intervention. If an undiagnosed patient refused further intervention, follow-up was considered as the second best strategy. Thus, this study continued until the last enrolled patient had been followed up for 2 years. Follow-up information was derived from outpatient clinics, by telephone or by fax contact.

Statistical analysis

Sample size was calculated based on the primary end point. The estimated diagnostic yields in the VBNA and NVBNA groups based on published records were 70% and 50%, respectively.13 21 22 Thus, at 80% power and α=0.05, we calculated that 190 patients would be required (n=95 in each group) to determine whether diagnostic yield improved with the addition of VBNA. We planned to enrol 200 patients to account for incomplete data or undiagnosed patients. We analysed the diagnostic yield and safety of the entire intent-to-treat population. Data from the per-protocol population that included all randomised patients with planned bronchoscopic procedures for peripheral lesions were also statistically analysed. Primary and secondary variables were analysed using the Pearson χ2 test and the Mann–Whitney U test. Continuous variables were assessed for normality in distribution and the Mann–Whitney test/description as medians was used. All p values were two-sided. A p value of <0.05 indicated statistical significance. All data were statistically analysed using IBM SPSS Statistics, V 18.

Results

We randomly assigned 102 and 97 patients to the VBNA and NVBNA groups. One and two patients in the NVBNA and VBNA groups, respectively, with endobronchially visible malignant or large (>3 cm) lesions were ineligible. We could not use VBN in one patient in the VBNA group and another refused bronchoscopy after assignment to the NVBNA group. We excluded these five patients from the per-protocol populations. The trial profile is shown in figure 2. Age, sex, lesion size and location in patients at baseline were similar between the groups (table 1).
Figure 2

CONSORT flow diagram. *All allocated patients were included in the intention-to-treat population. †Diagnoses established without operating virtual bronchoscopic navigation (VBN). ‡The bronchoscopic procedure was performed according to protocol. §Final diagnosis of this patient was not established; however, this patient was included in the per-protocol analysis.

Table 1

Baseline characteristics and final diagnoses

VBNA group (n=102)NVBNA group (n=97)
Age (years, median; range)69 (21–85)67 (27–82)
Male, n (%)64 (62.7)57 (58.8)
Lesion size (mm, median; range)18.0 (9.5–30.0)18.0 (7.0–30.0)
 <20 mm, n (%)59 (57.8)59 (60.8)
 20–30 mm, n (%)43 (42.2)38 (39.2)
Lesion location
 Rt. upper lobe, n (%)32 (31.4)35 (36.1)
 Rt. middle lobe, n (%)12 (11.8)6 (6.2)
 Rt. lower lobe, n (%)23 (22.5)18 (18.6)
 Lt. upper lobe, n (%)25 (24.5)21 (21.6)
 Lt. lower lobe, n (%)10 (9.8)17 (17.5)
Final diagnosis
Malignant disease n (%)
 Primary lung cancer n (%)69 (67.6)76 (78.4)
 Other malignant disease n (%)10 (9.8)4 (4.1)
Non-malignant disease n (%)
 Infectious disease n (%)17 (16.7)8 (8.2)
 Other benign condition n (%)5 (4.9)9 (9.3)
 Undetermined n (%)1 (1.0)0 (0)

Lt., left; NVBNA, non-virtual bronchoscopic navigation-assisted; Rt., right; VBNA, virtual bronchoscopic navigation-assisted.

CONSORT flow diagram. *All allocated patients were included in the intention-to-treat population. †Diagnoses established without operating virtual bronchoscopic navigation (VBN). ‡The bronchoscopic procedure was performed according to protocol. §Final diagnosis of this patient was not established; however, this patient was included in the per-protocol analysis. Baseline characteristics and final diagnoses Lt., left; NVBNA, non-virtual bronchoscopic navigation-assisted; Rt., right; VBNA, virtual bronchoscopic navigation-assisted. The proportions of primary lung cancer, other malignancies and non-malignant diseases were similar between the groups. Non-malignant diseases comprised tuberculosis, non-tuberculous mycobacterial infection, fungal disease, organising pneumonia, hamartoma and lipoma. Among bronchoscopically undiagnosed patients, 23 (44.2%) of 52 underwent video-assisted thoracoscopy and/or surgery and 8 (15.4%) were diagnosed by CT-guided FNA or repeated bronchoscopy. Twenty of the 21 patients who refused further intervention were followed up for 2 years. The results indicated a significant difference in diagnostic yield between arms both in the intent-to-treat (all randomly assigned patients, n=199) and the per-protocol populations (finally analysed patients, n=194). Diagnostic yield was significantly higher for the VBNA than for the NVBNA groups in both the intent-to-treat (82 (80.4%) of 102 vs 65 (67.0%) of 97; p=0.032) and per-protocol (80 (80.8%) of 99 vs 64 (67.4%) of 95; p=0.032; table 2) populations.
Table 2

Diagnostic yields in the intent-to-treat and per-protocol populations

Bronchoscopic diagnosisp Value
VBNANVBNA
Full intent-to-treat82/102 (80.4)65/97 (67.0)0.032
Per-protocol80/99 (80.8)64/95 (67.4)0.032

Data are shown as numbers of lesions/total lesions (%).

NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted.

Diagnostic yields in the intent-to-treat and per-protocol populations Data are shown as numbers of lesions/total lesions (%). NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted. Diagnostic yield did not differ significantly according to lesion size between the groups in the per-protocol population (table 3).
Table 3

Diagnostic yield according to lesion size in the per-protocol population

Lesion sizeBronchoscopic diagnosisp Value
VBNANVBNA
<20 mm44/58 (75.9)35/59 (59.3)0.056
20–30 mm36/41 (87.8)29/36 (80.6)0.382
Total80/99 (80.8)64/95 (67.4)0.032

Data are presented as numbers of lesions/total lesions (%).

NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted.

Diagnostic yield according to lesion size in the per-protocol population Data are presented as numbers of lesions/total lesions (%). NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted. Of the virtual images constructed based on data from the VBNA group, 98% agreed with actual images of the shape of each bronchial bifurcation on the route. The median generation of virtual bronchial images was six (range, 4–12 bronchi). The VBN system thus allowed insertion of the endoscope into significantly further generations of bronchi (VBNA vs NVBNA median (range): 4 (2–8) vs 4 (2–7); p<0.001; table 4). The endoscope was also accurately positioned in the VBNA group, with more targets being confirmed by EBUS (VBNA vs NVBNA: 92/99 (92.9%) vs 77/95 (81.1%); p=0.014). Numbers of biopsies and brushings/washes did not differ significantly between the groups. Total examination duration was significantly shorter in the VBNA than in the NVBNA group (median (range): 24.0 (8.7–47.0) vs 26.2 (11.6–58.6) min; p=0.016). The interval to starting sample collection was significantly shorter in the VBNA versus the NVBNA group (8.1 (2.8–39.2) vs (9.8 (2.3–42.3) min; p=0.045). The duration of x-ray fluoroscopy exposure did not differ significantly between the groups. No severe or moderate adverse events were associated with bronchoscopy except for mild pneumothorax that did not require chest drainage in a patient from the NVBNA group.
Table 4

Bronchoscopic outcomes in the per-protocol population

VBNANVBNAp Value
Endoscopically inserted bronchial generation (n, median) (range)4 (2–8)4 (2–7)<0.001
EBUS-visualised peripheral lesion, n (%)92 (92.9)77 (81.1)0.014
Sampling by biopsy, (n, median) (range)5 (0–12)4 (0–12)0.113
Sampling by brushing/washing (n, median) (range)3 (0–6)3 (0–5)0.42
Duration
Total examination (min, median) (range)24.0 (8.7–47.0)26.2 (11.6–58.6)0.016
Initial sampling (min, median) (range)8.1 (2.8–39.2)9.8 (2.3–42.3)0.045
x-ray fluoroscopy exposure (min, median) (range)9.7 (1.5–22.7)11.0 (1.3–31.0)0.058

EBUS, endobronchial ultrasound; NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted.

Bronchoscopic outcomes in the per-protocol population EBUS, endobronchial ultrasound; NVBNA, non-virtual bronchoscopic navigation-assisted; VBNA, virtual bronchoscopic navigation-assisted.

Discussion

This is the first prospective, multicentre, randomised trial to examine the value of using a VBN system to assist radial EBUS. The findings showed that VBN-assisted EBUS with a guide sheath significantly improved the diagnostic yield of small pulmonary peripheral lesions to 80.4%, which was 13% higher than that in the NVBNA group (67.0%). The diagnostic yield for similar lesions in our previous study using a conventional or thin bronchoscope assisted by VBN under fluoroscopy was 62.5%.23 The diagnostic yield was 58.3% in another of our studies using EBUS.13 The high diagnostic yield in the present study was achieved by combining these two procedures. Moreover, although the study cohort was small and diagnostic yields for lesions <20 mm did not differ significantly, the diagnostic yield with VBNA was nevertheless high at 75.9%. Comparison is difficult since x-ray fluoroscopy was used in this study, but the diagnostic yield with EBUS + VBN was comparable with that reported by Eberhardt et al.18 One advantage of VBN compared with EMN is simplicity. Operations such as steering the sensor probe or registration during tests are not required to superimpose the electromagnetic sensor position and CT information as with EMN.14 Furthermore, the bronchoscope is advanced together with virtual image indications in VBN, which is essentially identical to conventional bronchoscope manipulation.19 Thus, bronchoscopists with basic skills can easily operate this system after practice on a simulator. Locatable guides attached to the EMN sensor probe are single use, which imposes a cost burden of US$700–1000 per patient depending on market price.24 The diagnostic sensitivity of TTNA differs depending on the technique and lesion size, but it is 92% with FNA under CT guidance6 and 82–90% even for lesions ≤2 cm. However, the main complication with FNA under CT guidance is pneumothorax, which occurs at an incidence of 15–42% 25–27 and is quite frequent with small lesions or emphysema.27 Reported complications comprise bronchial haemorrhage,25 needle tract implantation and air embolism.28 In contrast, the complication rate with transbronchial lung biopsy is 0.2–5% for pneumothorax and 1.2–9% for haemorrhage.9 29 30 Pneumothorax or other complications have not been found in other studies of EBUS + VBN to date, including the present study.21 22 The diagnostic sensitivity of EBUS + VBN may not be as high as that with CT-guided FNA, but it is considerably higher than the diagnostic sensitivity of normal bronchoscopy indicated in the ACCP guidelines.8 Therefore, considering the low rate of complications, VBN combined with EBUS may be a viable option for diagnosing small peripheral lesions. To our knowledge, this is the first report to describe the duration of navigational bronchoscopy, and that the amount of time required for guidance was decreased in the VBNA group. Moreover, VBN improved diagnostic yield while decreasing the overall duration of the examination by ∼2 min. This is thought to be significant in terms of patient comfort, especially considering that patients endured the procedure under local anaesthesia. Although the time required for fluoroscopy tended to decrease in the VBNA group, the difference did not reach statistical significance. Fluoroscopy duration before and after initial sampling was not measured in this study, but almost all of the fluoroscopic exposure was taken up by specimen sampling to confirm proper device use, such as forceps opening and cutting, as well as brushing at adequate sites. Steinfort et al reported that radiation exposure from fluoroscopy used together with EBUS does not pose a clinical problem.31 However, we found that radiation exposure accounted for ∼40% of the total duration of the examination. More reliable sampling devices are needed for EBUS with a guide sheath. We identified the following limitations. The precision of VB decreases when CT data are inadequate during VB; for example, the branch order that can be visualised is lower when slices are too thick.32 Under such circumstances, repeat CT might be required, which imposes additional cost. Many of the patients in this study were referred from private clinics after abnormalities on plain x-rays had been identified. Therefore, row CT data with a slice thickness of ≤2 mm were collected from the start with multidetector CT instruments at the institution where the present study was conducted and, as a result, virtual images could be created up to sixth generation bronchi. In contrast, the amount of CT data increases with thinner slices and more time is required to create VB images. Most of the time required to create VB images in this study was due to PC processing, but the VB images were created over a period of ∼20 min. This depends to some extent on the performance of the software and PC hardware, which could be further enhanced. The VBN system used in the present study (Bf-NAVI; Cybernet Systems, Tokyo, Japan) has been promoted mainly in Japan. The automatic tracking system for the VBN system used herein will allow automatic synchronisation of the virtual to the actual bronchoscopic view.33 Another VBN system with an automatic tracking system has recently been developed.24 34 This study showed that diagnostic yield improved with VBN when combined with EBUS which is still not globally applied. We also combined VBN with fluoroscopy, and confirmed lesions in 83% of patients with plain x-rays. Although VBN has been applied without fluoroscopy,24 when not combined with EBUS it is usually combined with CT20 35 or fluoroscopy23 to confirm lesions. Randomised studies with each of these combinations may be necessary to define the diagnostic value of VBN.
  33 in total

1.  Endobronchial ultrasound-guided transbronchial lung biopsy in solitary pulmonary nodules and peripheral lesions.

Authors:  F J F Herth; A Ernst; H D Becker
Journal:  Eur Respir J       Date:  2002-10       Impact factor: 16.671

2.  Radiation dose to patients and clinicians during fluoroscopically-guided biopsy of peripheral pulmonary lesions.

Authors:  Daniel P Steinfort; Paul Einsiedel; Louis B Irving
Journal:  Respir Care       Date:  2010-11       Impact factor: 2.258

3.  Electromagnetic navigation during flexible bronchoscopy.

Authors:  Yehuda Schwarz; Atul C Mehta; Armin Ernst; Felix Herth; Ahuva Engel; Doron Besser; Heinrich D Becker
Journal:  Respiration       Date:  2003 Sep-Oct       Impact factor: 3.580

4.  CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.

Authors:  Yoshiharu Ohno; Hiroto Hatabu; Daisuke Takenaka; Takanori Higashino; Hirokazu Watanabe; Chiho Ohbayashi; Kazuro Sugimura
Journal:  AJR Am J Roentgenol       Date:  2003-06       Impact factor: 3.959

5.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

6.  Real-time interactive virtual endoscopy of the tracheo-bronchial system: influence of CT imaging protocols and observer ability.

Authors:  K Neumann; J Winterer; M Kimmig; D Burger; A Einert; K H Allmann; M Hauer; M Langer
Journal:  Eur J Radiol       Date:  2000-01       Impact factor: 3.528

7.  Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules.

Authors:  W A Baaklini; M A Reinoso; A B Gorin; A Sharafkaneh; P Manian
Journal:  Chest       Date:  2000-04       Impact factor: 9.410

8.  CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle.

Authors:  F Laurent; V Latrabe; B Vergier; M Montaudon; J M Vernejoux; J Dubrez
Journal:  Clin Radiol       Date:  2000-04       Impact factor: 2.350

Review 9.  Tissue diagnosis of suspected lung cancer: selecting between bronchoscopy, transthoracic needle aspiration, and resectional biopsy.

Authors:  Rex C W Yung
Journal:  Respir Care Clin N Am       Date:  2003-03

Review 10.  Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence.

Authors:  Gilbert Schreiber; Douglas C McCrory
Journal:  Chest       Date:  2003-01       Impact factor: 9.410

View more
  65 in total

1.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

2.  Bronchoscopy Using Virtual Navigation and Endobronchial Ultrasonography with a Guide Sheath (EBUS-GS) with or without Fluoroscopy for Peripheral Pulmonary Lesions.

Authors:  Motoko Tachihara; Daisuke Tamura; Tatsunori Kiriu; Shuntaro Tokunaga; Yukihisa Hatakeyama; Haruko Shinke; Tatsuya Nagano; Kyosuke Nakata; Nobuko Hazeki; Hiroshi Kamiryo; Kazuyuki Kobayashi; Yoshihiro Nishimura
Journal:  Kobe J Med Sci       Date:  2018-03-27

3.  Transbronchial Catheter Aspiration and Transbronchial Needle Aspiration in the Diagnostic Workup of Peripheral Lung Lesions.

Authors:  Karl-Josef Franke; Melanie Hein; Ulrike Domanski; Georg Nilius; Maik Schroeder; Jeremias Wohlschlaeger; Dirk Theegarten
Journal:  Lung       Date:  2015-07-09       Impact factor: 2.584

4.  The many facets of diagnostic bronchoscopy for pulmonary ground glass nodules.

Authors:  Christine Chavez; Takehiro Izumo
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

5.  Does AQuIRE challenge the role of navigational bronchoscopy for peripheral pulmonary lesions?

Authors:  Annette McWilliams
Journal:  Ann Transl Med       Date:  2016-10

6.  Electromagnetic navigation bronchoscopy: A descriptive analysis.

Authors:  Steven Leong; Hong Ju; Henry Marshall; Rayleen Bowman; Ian Yang; Ann-Maree Ree; Cathy Saxon; Kwun M Fong
Journal:  J Thorac Dis       Date:  2012-04-01       Impact factor: 2.895

7.  Virtual bronchoscopy in the era of multi-detector computed tomography: Is there any reality?

Authors:  Jyotindu Debnath; Raju A George; Lovleen Satija; Samsuddin Ahmed; S P Rai; Shuvendu Roy
Journal:  Med J Armed Forces India       Date:  2013-05-10

Review 8.  Role of electromagnetic navigational bronchoscopy in pulmonary nodule management.

Authors:  Aditya Goud; Chanukya Dahagam; David P Breen; Saiyad Sarkar
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

Review 9.  Bronchoscopy for the diagnosis of peripheral lung lesions.

Authors:  Samjot Singh Dhillon; Kassem Harris
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 10.  Advanced imaging (positron emission tomography and magnetic resonance imaging) and image-guided biopsy in initial staging and monitoring of therapy of lung cancer.

Authors:  Shaheen Islam; Ronald C Walker
Journal:  Cancer J       Date:  2013 May-Jun       Impact factor: 3.360

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.