Literature DB >> 12760939

CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.

Yoshiharu Ohno1, Hiroto Hatabu, Daisuke Takenaka, Takanori Higashino, Hirokazu Watanabe, Chiho Ohbayashi, Kazuro Sugimura.   

Abstract

OBJECTIVE: The purpose of our study was to determine the diagnostic accuracy and to analyze the factors influencing the diagnostic accuracy and incidences of pneumothorax and chest tube insertion rates for percutaneous CT-guided needle biopsy of small (< or = 20 mm) solitary pulmonary nodules. SUBJECTS AND METHODS: One hundred sixty-two patients with 162 small solitary pulmonary nodules underwent CT-guided transthoracic needle aspiration biopsy. The overall diagnostic accuracy, pneumothorax rate, and chest tube insertion rate were calculated. Factors influencing the diagnostic accuracy and pneumothorax rate were statistically evaluated. Influencing factors, diagnostic accuracies, pneumothorax rates, and chest tube insertion rates were statistically compared.
RESULTS: Overall diagnostic accuracy, pneumothorax rate, and chest tube insertion rate were 77.2%, 28.4%, and 2.5%, respectively. Diagnostic accuracy was significantly affected by length of needle path and lesion size (p < 0.05). The pneumothorax rate was significantly affected by the percentage of predicted forced expiratory volume in 1 sec, the number of punctures, and the needle path length (p < 0.05). The chest tube insertion rate was significantly affected by the number of punctures (p < 0.05). For diagnostic accuracy, needle path lengths of 40 mm or less and lesion sizes greater than 10 mm were significantly more accurate than other factors (p < 0.05). For pneumothorax rates, a percentage of predicted forced expiratory volume in 1 sec of greater than 70%, a single puncture, and a needle path length of 40 mm or less were significantly lower than other factors (p < 0.05).
CONCLUSION: CT-guided transthoracic needle aspiration biopsy is a useful diagnostic tool for small solitary pulmonary nodules smaller than 20 mm in diameter. The diagnostic accuracy is significantly improved for large (> 10 mm) lesion size and short (< or = 40 mm) needle path length.

Entities:  

Mesh:

Year:  2003        PMID: 12760939     DOI: 10.2214/ajr.180.6.1801665

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  79 in total

1.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

2.  Percutaneous cavitary lavage in the diagnosis of pulmonary cavities.

Authors:  Umit Belet; Serhat Findik; Zafer Ozmen; Atilla Guven Atici; Huseyin Akan
Journal:  J Thorac Dis       Date:  2013-08       Impact factor: 2.895

3.  A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety.

Authors:  Daniel Yaffe; Matthew Koslow; Hassan Haskiya; David Shitrit
Journal:  Eur Radiol       Date:  2015-04-23       Impact factor: 5.315

4.  Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Authors:  M J Choi; Y Kim; Y S Hong; S S Shim; S M Lim; J K Lee
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

5.  CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax.

Authors:  Toshihiro Iguchi; Takao Hiraki; Hideo Gobara; Hiroyasu Fujiwara; Yusuke Matsui; Shinichiro Miyoshi; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

6.  Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.

Authors:  Çağlar Uzun; Zehra Akkaya; Ebru Düşünceli Atman; Evren Üstüner; Elif Peker; Başak Gülpınar; Atilla Halil Elhan; Koray Ceyhan; Kayhan Çetin Atasoy
Journal:  Diagn Interv Radiol       Date:  2017 Mar-Apr       Impact factor: 2.630

7.  Factors affecting the accuracy and safety of computed tomography-guided biopsy of intrapulmonary solitary nodules ≤30 mm in a retrospective study of 155 patients.

Authors:  Gang Zhao; Xiaobao Shi; Wei Sun; Hongyuan Liang; Xiaonan Mao; Feng Wen; Ming Shan; Xihai Wang; Zaiming Lu
Journal:  Exp Ther Med       Date:  2017-03-02       Impact factor: 2.447

8.  Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies.

Authors:  M De Filippo; M Onniboni; M Rusca; P Carbognani; L Ferrari; A Guazzi; A Casalini; E Verardo; V Cataldi; M Tiseo; N Sverzellati; G Chiari; E Rabaiotti; A Corsi; G Cacciani; M Sommario; A Ardizzoni; M Zompatori
Journal:  Radiol Med       Date:  2008-09-25       Impact factor: 3.469

9.  Diagnosis of peripheral pulmonary carcinoid tumor using endobronchial ultrasound.

Authors:  Daniel P Steinfort; Moira Finlay; Louis B Irving
Journal:  Ann Thorac Med       Date:  2008-10       Impact factor: 2.219

10.  Computed tomography-guided fine needle aspiration cytology of solitary pulmonary nodules suspected to be bronchogenic carcinoma: Experience of a general hospital.

Authors:  Sumana Mukherjee; Gautam Bandyopadhyay; Aparna Bhattacharya; Ritu Ghosh; Gopinath Barui; Rupam Karmakar
Journal:  J Cytol       Date:  2010-01       Impact factor: 1.000

View more