PURPOSE OF REVIEW: Significant limitations exist for traditional noninvasive cardiac imaging with regard to equivocal or indeterminate findings that result in repetitive testing or unnecessary referral to invasive coronary angiography (ICA). Recent hardware and software advances in multislice computed tomography angiography have achieved high spatial and temporal resolution to allow accurate noninvasive assessment of coronary arteries. This poses a paradigm shift in management of patients with suspected coronary artery disease (CAD). RECENT
FINDINGS: Multicenter studies showed that coronary computed tomography angiography (CCTA) has a very high diagnostic accuracy, and, in particular, a very high negative predictive value (>98%) in detecting coronary stenosis when compared with ICA. In addition to its diagnostic ability, recent evidence-based outcome data have also validated the value of CCTA in predicting cardiac events. Absence of CAD on CCTA conveys excellent prognosis, whereas increasing disease severity and extent are associated with worsening outcome. Furthermore, CCTA allows comprehensive assessment of coronary stenosis, plaque burden, left ventricular morphology, function, perfusion and viability. One concern with CCTA is the issue of ionizing radiation exposure. Recent technical progress allows dramatic reduction of radiation dose. The newest generation scanner is capable of producing CCTA of diagnostic quality with a dose of less than 1 mSv. A multisociety guideline for appropriate clinical indications for cardiac computed tomography was recently published.
SUMMARY: When used appropriately, CCTA has been established as a valid noninvasive imaging alternative to ICA in selected patients at low to intermediate risk of CAD.

Entities:  

Mesh:

Year:  2011        PMID: 21743316     DOI: 10.1097/HCO.0b013e32834938c6

Source DB:  PubMed          Journal:  Curr Opin Cardiol        ISSN: 0268-4705            Impact factor:   2.161


  8 in total

1.  Coronary computed tomography angiography.

Authors:  Gilat Grunau; Jonathon Leipsic
Journal:  CMAJ       Date:  2015-08-10       Impact factor: 8.262

2.  ECG-gated coronary angiography enables submillisievert imaging in invasive cardiology.

Authors:  E Kuon; S B Felix; K Weitmann; I Büchner; A Hummel; M Dörr; T Reffelmann; A Riad; M C Busch; K Empen
Journal:  Herz       Date:  2014-10-04       Impact factor: 1.443

3.  Latest-generation catheterization systems enable invasive submillisievert coronary angiography.

Authors:  E Kuon; K Weitmann; A Hummel; M Dörr; T Reffelmann; A Riad; M C Busch; S B Felix; W Hoffmann; K Empen
Journal:  Herz       Date:  2013-12-08       Impact factor: 1.443

4.  Myocardial perfusion imaging in patients with a recent, normal exercise test.

Authors:  Ann Bovin; Ib C Klausen; Lars J Petersen
Journal:  World J Cardiol       Date:  2013-03-26

5.  Cerebrovascular ischemic event - what about the coronaries.

Authors:  Joseph C Lee; Alaa Alghamry
Journal:  Anatol J Cardiol       Date:  2021-07       Impact factor: 1.475

6.  Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference.

Authors:  Wei Guo; Xin Liu; Zhifan Gao; Sandeep Pirbhulal; Wenhua Huang; Wan-Hua Lin; Heye Zhang; Ning Tan; Yuan-Ting Zhang
Journal:  Biomed Eng Online       Date:  2015-05-30       Impact factor: 2.819

7.  Effect of a Novel Intracycle Motion Correction Algorithm on Dual-Energy Spectral Coronary CT Angiography: A Study with Pulsating Coronary Artery Phantom at High Heart Rates.

Authors:  Yan Xing; Yuan Zhao; Ning Guo; Cun-Xue Pan; Gulina Azati; Yan-Wei Wang; Wen-Ya Liu
Journal:  Korean J Radiol       Date:  2017-09-21       Impact factor: 3.500

8.  Clinical evaluation of new automatic coronary-specific best cardiac phase selection algorithm for single-beat coronary CT angiography.

Authors:  Hui Wang; Lei Xu; Zhanming Fan; Junfu Liang; Zixu Yan; Zhonghua Sun
Journal:  PLoS One       Date:  2017-02-23       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.