Use of benchtop exactive high resolution and high mass accuracy orbitrap mass spectrometer for screening in horse doping control.

Yves Moulard1, Ludovic Bailly-Chouriberry, Sophie Boyer, Patrice Garcia, Marie-Agnès Popot, Yves Bonnaire.   

Abstract

Liquid chromatography-mass spectrometry (LC-MS) has been widely used in doping control laboratories over the last two decades. Currently, simple quadrupole, triple quadrupole and ion trap are the most commonly employed analyzers in toxicological analysis. Nevertheless, the main lack of these technologies is the restricted number of target compounds simultaneously screened without loss of sensitivity. In this article we present an innovative screening approach routinely applied in the French horse doping control laboratory based on high resolution (50000) and high mass accuracy (<5 ppm) in full scan MS mode for more than 235 target analytes screened from an initial volume of 5 mL of urine. The sample preparation was classically founded on solid phase extraction by means of reverse phase C18 cartridges. LC-MS analyses were carried out on a Shimadzu binary HPLC pumps linked to a C18 Sunfire column associated with the high resolution exactive benchtop orbitrap mass spectrometer. This screening was performed alternatively in positive-negative ionization mode during the same run. Thus, the identification of compounds of interest was made using their exact mass in positive-negative ionization mode at their expected retention time. All data obtained were processed by ToxID software (ThermoFisherScientific) which is able to identify a molecule by theoretical mass and retention time. In order to illustrate this innovative technology applied in our laboratory, sample preparation, validation data performed on 20 target compounds from 16 different horse urine samples, chromatograms and spectra will be discussed in this paper.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21742125     DOI: 10.1016/j.aca.2011.01.006

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Qualitative aspects and validation of a screening method for pesticides in vegetables and fruits based on liquid chromatography coupled to full scan high resolution (Orbitrap) mass spectrometry.

Authors:  Hans G J Mol; Paul Zomer; Maarten de Koning
Journal:  Anal Bioanal Chem       Date:  2012-06-05       Impact factor: 4.142

Review 2.  Mass spectrometry of structurally modified DNA.

Authors:  Natalia Tretyakova; Peter W Villalta; Srikanth Kotapati
Journal:  Chem Rev       Date:  2013-02-26       Impact factor: 60.622

3.  Droplet Digital PCR Detection of the Erythropoietin Transgene from Horse Plasma and Urine for Gene-Doping Control.

Authors:  Teruaki Tozaki; Aoi Ohnuma; Masaki Takasu; Mio Kikuchi; Hironaga Kakoi; Kei-Ichi Hirota; Kanichi Kusano; Shun-Ichi Nagata
Journal:  Genes (Basel)       Date:  2019-03-21       Impact factor: 4.096

4.  Identification of metabolomic changes in horse plasma after racing by liquid chromatography-high resolution mass spectrometry as a strategy for doping testing.

Authors:  Toshiki Ueda; Teruaki Tozaki; Satoshi Nozawa; Kenji Kinoshita; Hitoshi Gawahara
Journal:  J Equine Sci       Date:  2019-10-02

5.  Analytical Approaches in Official Food Safety Control: An LC-Orbitrap-HRMS Screening Method for the Multiresidue Determination of Antibiotics in Cow, Sheep, and Goat Milk.

Authors:  Severyn Salis; Nicola Rubattu; Federica Rubattu; Maurizio Cossu; Andrea Sanna; Giannina Chessa
Journal:  Molecules       Date:  2022-09-20       Impact factor: 4.927

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.