Literature DB >> 21740556

A new resorbable device for ligation of blood vessels - A pilot study.

Odd V Höglund1, Ragnvi Hagman, Kerstin Olsson, Jonas Mindemark, Niklas Borg, Anne-Sofie Lagerstedt.   

Abstract

BACKGROUND: During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.
METHODS: The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.
RESULTS: The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, n = 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, n = 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.
CONCLUSIONS: Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21740556      PMCID: PMC3141562          DOI: 10.1186/1751-0147-53-47

Source DB:  PubMed          Journal:  Acta Vet Scand        ISSN: 0044-605X            Impact factor:   1.695


  12 in total

1.  Injection moulding of biodegradable implants.

Authors:  R von Oepen; W Michaeli
Journal:  Clin Mater       Date:  1992

Review 2.  Radiopaque polymeric materials for medical applications. Current aspects of biomaterial research.

Authors:  F Mottu; D A Rüfenacht; E Doelker
Journal:  Invest Radiol       Date:  1999-05       Impact factor: 6.016

3.  Nylon cable band reactions in ovariohysterectomized bitches.

Authors:  R E Werner; A J Straughan; D Vezin
Journal:  J Am Vet Med Assoc       Date:  1992-01-01       Impact factor: 1.936

4.  Laparoscopic ovariectomy in mares using a polyamide tie-rap.

Authors:  Stefan M Cokelaere; Ann M J G Martens; Peter Wiemer
Journal:  Vet Surg       Date:  2005 Nov-Dec       Impact factor: 1.495

5.  Hemostatic laparoscopic partial nephrectomy: cable-tie compression.

Authors:  J A Cadeddu; T S Corwin; O Traxer; C Collick; H H Saboorian; M S Pearle
Journal:  Urology       Date:  2001-03       Impact factor: 2.649

6.  Partial splenic resection using nylon cable tie ligatures in rhesus monkeys.

Authors:  R J Adams; O Narayan
Journal:  Lab Anim Sci       Date:  1993-06

7.  The Hem-o-lok clip is safe for laparoscopic nephrectomy: a multi-institutional review.

Authors:  Lee Ponsky; Edward Cherullo; Alireza Moinzadeh; Mihir Desai; Jihad Kaouk; Georges-Pascal Haber; David Chen; Christopher Ng; Gerhard Fuchs; Dinesh Singh; Antonio Finelli; Igor Frank; Surena Matin
Journal:  Urology       Date:  2008-03-04       Impact factor: 2.649

8.  Evaluation of the tensile strengths of four monofilament absorbable suture materials after immersion in canine urine with or without bacteria.

Authors:  Chelsea B Greenberg; Ellen B Davidson; Danielle D Bellmer; Rebecca J Morton; Mark E Payton
Journal:  Am J Vet Res       Date:  2004-06       Impact factor: 1.156

9.  Use of Hem-o-lok Clips for Vascular Control During Retroperitoneoscopic Nephrectomy in Children.

Authors:  Pranjal Modi; S J Rizvi; Rahul Gupta
Journal:  J Endourol       Date:  2009-07-20       Impact factor: 2.942

10.  Breaking strength and elasticity of synthetic absorbable suture materials incubated in phosphate-buffered saline solution, milk, and milk contaminated with Streptococcus agalactiae.

Authors:  Sylvain Nichols; David E Anderson
Journal:  Am J Vet Res       Date:  2007-04       Impact factor: 1.156

View more
  3 in total

1.  Cystic duct pressures after ligation with a novel absorbable device in an ex vivo caprine cholecystectomy model.

Authors:  Andrea J Sundholm Tepper; Odd V Höglund; Bonnie G Campbell; Chi-Ya Chen; Boel A Fransson
Journal:  Can J Vet Res       Date:  2017-07       Impact factor: 1.310

2.  Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer--feasibility and long-term follow-up study.

Authors:  Odd V Höglund; Jessica Ingman; Fredrik Södersten; Kerstin Hansson; Niklas Borg; Anne-Sofie Lagerstedt
Journal:  BMC Res Notes       Date:  2014-11-20

3.  Ligation of the mesovarium in dogs with a self-locking implant of a resorbable polyglycolic based co-polymer: a study of feasibility and comparison to suture ligation.

Authors:  Matheus Roberto da Mota Costa; André Lacerda de Abreu Oliveira; Renato Moran Ramos; Leonardo Waldstein de Moura Vidal; Niklas Borg; Odd V Höglund
Journal:  BMC Res Notes       Date:  2016-04-27
  3 in total