| Literature DB >> 1537693 |
R E Werner1, A J Straughan, D Vezin.
Abstract
Nylon cable bands used as ligatures caused postsurgical complications in 5 ovariohysterectomized bitches. Clinical signs included fever, stiffness, strangury, draining fistulae, vaginal discharge, and tenesmus. Most signs first appeared several years after surgery, and all signs were resolved after removal of the bands. On the basis of our experience, we suggest that nylon cable bands not be used for ovariohysterectomy ligations.Entities:
Mesh:
Substances:
Year: 1992 PMID: 1537693
Source DB: PubMed Journal: J Am Vet Med Assoc ISSN: 0003-1488 Impact factor: 1.936