Abstract
There is mounting evidence that the aerosol transmission route plays a significant role in the spread of influenza in temperate regions and that the efficiency of this route depends on humidity. Nevertheless, the precise mechanisms by which humidity might influence transmissibility via the aerosol route have not been elucidated. We hypothesize that airborne concentrations of infectious influenza A viruses (IAVs) vary with humidity through its influence on virus inactivation rate and respiratory droplet size. To gain insight into the mechanisms by which humidity might influence aerosol transmission, we modeled the size distribution and dynamics of IAVs emitted from a cough in typical residential and public settings over a relative humidity (RH) range of 10-90%. The model incorporates the size transformation of virus-containing droplets due to evaporation and then removal by gravitational settling, ventilation, and virus inactivation. The predicted concentration of infectious IAVs in air is 2.4 times higher at 10% RH than at 90% RH after 10 min in a residential setting, and this ratio grows over time. Settling is important for removal of large droplets containing large amounts of IAVs, while ventilation and inactivation are relatively more important for removal of IAVs associated with droplets <5 µm. The inactivation rate increases linearly with RH; at the highest RH, inactivation can remove up to 28% of IAVs in 10 min. Humidity is an important variable in aerosol transmission of IAVs because it both induces droplet size transformation and affects IAV inactivation rates. Our model advances a mechanistic understanding of the aerosol transmission route, and results complement recent studies on the relationship between humidity and influenza's seasonality. Maintaining a high indoor RH and ventilation rate may help reduce chances of IAV infection.Entities:
Mesh:
Year: 2011 PMID: 21731764 PMCID: PMC3123350 DOI: 10.1371/journal.pone.0021481
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Prior studies of respiratory droplet size distributions.
| Activity | Droplet size (µm) | Droplet number | Experimental conditions | Measurement methods | Adjustment for evaporation | Reference | |
| GM (GSD) | Range | ||||||
| Cough | 12.1 (2.6) | 1–2000 | 5000 | NA | Microscope | Factor of 4 |
|
| 16.0 (5.8) | 1→1471 | 466 | NA | Bone paper and 0.45-µm filter | As measured |
| |
| 0.5 (1.7) | <0.6–2.5 | 420 | 24°C, 45%RH;35°C, 23%RH | Optical particle counter (OPC), electron microscope | As measured |
| |
| 8.4 (2.2) | NA | NA | 95% RH | Aerodynamic particle sizer (APS), scanning mobility particle sizer, OPC | As measured, assumed to be the original size |
| |
| 13.5 | 2–1000 | NA | 24.9°C, 73.9% RH | Interferometric Mie imaging (>2 µm), particle image velocimetry | As measured |
| |
| 1.8 | 0.3–20 | NA | 27°C, 59.4% RH | Expiratory droplet investigation system, APS | As measured |
| |
| 96.6 (2.4) | 0–1500 | 42 | 28°C, 70% RH | Microscope, aerosol spectrometer | Factor of 3 |
| |
| Sneeze | 8.2 (2.3) | 1–2000 | 1×106 | NA | Microscope | Factor of 4 |
|
| Speak | 11.9 (2.8) | 1–1000 | 252 | NA | Microscope | Factor of 4 |
|
| 16 | 2–1000 | NA | 24.9°C, 73.9% RH | Interferometric Mie imaging (>2 µm), particle image velocimetry | As measured |
| |
| 62.1 (1.8) | 0–1000 | 253 | 28°C, 70% RH | Microscope, aerosol spectrometer | Factor of 3 |
| |
Geometric mean (GM) and geometric standard deviation (GSD) calculated by methods presented in [51] or cited as reported in the original papers.
Whether droplet sizes were adjusted upward to account for evaporation or were reported as measured.
Calculated from data in Table 3 in [20].
Calculated from data in Table 1 in [15]; droplet diameter upper end assumed to be 2000 µm.
Calculated from data in Table IV in [22].
No data on GSD reported.
Reported modal diameter.
Calculated from data in Table 2 in [19], only results from experiments without food dye were used.
Counting aloud from 1 to 100.
Figure 1Log-probability plot of droplet size distribution from a cough, adapted from Duguid [.
D is the initial droplet size in µm, and z is the corresponding quantile of a normal distribution with the same cumulative probability.
Inactivation of airborne IAVs at 20–24.5°C over 1 h.
| T (min) | Viability ( | ||||
| 20–22% | 34–36% | 50–51% | 64–65% | 81% | |
| 0.017 (1 s) | 0.75 | 0.86 | 0.84 | 0.77 | 0.67 |
| 5 | 0.77 | 0.93 | 0.62 | 0.45 | 0.55 |
| 30 | 0.65 | 0.58 | 0.49 | 0.29 | 0.22 |
| 60 | 0.64 | 0.59 | 0.29 | 0.15 | 0.13 |
Experimental data from Harper [12].
Average RH.
k = slope of ln(S) versus t.
Intercept of the plot of ln(S) versus t.
r 2 of the plot of ln(S) versus t.
Respiratory droplet size transformation.
| RH | Model-based | Experimentally derived | Diff. | ||
|
|
|
| |||
| 10% | 0.401 | 0.402 | 0.402 | 0.391 | 2.61% |
| 20% | 0.407 | 0.407 | 0.407 | 0.395 | 3.06% |
| 30% | 0.412 | 0.412 | 0.412 | 0.398 | 3.42% |
| 40% | 0.416 | 0.417 | 0.417 | 0.401 | 3.98% |
| 50% | 0.422 | 0.423 | 0.424 | 0.427 | −0.90% |
| 60% | 0.429 | 0.431 | 0.432 | 0.437 | −1.19% |
| 70% | 0.439 | 0.443 | 0.444 | 0.449 | −1.20% |
| 80% | 0.456 | 0.464 | 0.465 | 0.464 | 0.02% |
| 90% | 0.490 | 0.513 | 0.516 | 0.502 | 2.63% |
Calculated according to the SS-VA model of Mikhailov et al. [23].
Calculated based on volume additivity using experimental data from Tang et al. [25] and Bagger et al. [26].
Difference between modeled and experimental D/D ratios for D = 10 µm.
Figure 2IAV inactivation rate versus RH.
IAV inactivation rates (k) for each RH over 1 h were calculated based on experimental data adapted from Harper [12].
Figure 3Evolution of infectious airborne IAV concentrations and size distributions.
Time series of airborne, infectious IAV concentrations following a cough into residential (A) and public (B) settings at 10–90% RH. The horizontal dashed line indicates 99.9% removal. Evolution over time of airborne, infectious IAV size distribution following a cough into residential (C) and public (D) settings at 50% RH.
Figure 4IAV size distributions.
Infectious IAV size distributions at various RHs in residential (A) and public (B) settings with a volume of 50 m3 and a height of 2.5 m, 10 min after a cough.
Figure 5IAV removal mechanisms.
Infectious IAV removal efficiencies due to settling, ventilation, and inactivation in residential (A) and public (B) settings at different RHs. Removal efficiency of settling, ventilation, and inactivation as a function of droplet size in residential (C) and public (D) settings at 50% RH. Removal efficiencies are shown for each mechanism independently and do not sum to 100% because in actuality, more than one mechanism may act on the same virus/droplet.